Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1
.) : Setting of the normal/reverse output switching and hysteresis/window comparator mode switching are performed with the function selection mode [F 1] OUT1 setting and [F 2] OUT2 setting. Peak/bottom value indication The max. (min.) pressure when the power is supplied is detected and updated.
Standard condition [F 4] [F 5] [eES] Response time [1.00] 1 second Specifications / Outline with Dimensions [F 6] [dSP] Display mode [ inS] Instantaneous flow [F 7] [ inP] External input [ r_r ] Accumulated flow external reset Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about the product specifications and outline dimensions. [1E2] 100-
Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.
Specifications Fluid Air Operating pressure range PSI (MPa) Body ported type 22~100 (0.15 to 0.7) Internal pilot Max. 122 Ambient and fluid temperature F 15 or less Response time ms 10 Max. operating frequency Hz Non-locking push type, Push-locking slotted type Manual override Individual pilot exhaust type.
After washing the element, make sure the base seal is properly mounted. 500 A Vertical Suction Filter FHIA Series Dimensions Differential pressure indicator 16 B (34) F OUT Removal dimension K H F OUT D E C H Differential pressure indication switch FH FH 62 HOW (65) F IN 4 x I OUT A J G (mm) A B C D E F G H I J K Model Weight (kg) FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA
) NPTF Nil F N Voltage 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Other Manual override/Classification 1 2 3 4 5 6 7 9 Electrical entry Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Nil A B Grommet Grommet terminal Conduit terminal DIN terminal G E T D Light/Surge voltage suppressor
Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.
F Thread type Rc G NPT NPTF Nil F N T Option Part No. Description Part no.
Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.
) 258-9200-www.stevenengineering.com Nil Rc G NPT NPTF Option F N T Option Part No.
Thread T F N Orifice size 2 3 4 5 6 Rc(PT) NPTF G(PF) NPT 3mm 4.5mm 6mm 8mm 10mm Refer to table q for configuration. Port size 01 02 03 04 1 8 1 4 Valve/Body 0 2 Normally closed (N.C.)/single unit Normally open (N.O)/single unit 3 8 1 2 Refer to table q for configuration.
Nil V Standard For vacuum X505 VPA500 series Port size Symbol Port size VPA300 1/8 1/4 3/8 1/2 VPA500 VPA700 01 02 03 04 Bracket Nil F Without bracket With bracket Thread type Type of actuation A B N.C. (Normally closed) N.O. (Normally open) Nil F N T Rc G NPT NPTF VPA700 series Specifications Fluid Air Type of actuation N.C. or N.O.
Applicable Model Model AR20-A AR25-A AR30-A AR40-A AR40-06-A Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 A 30 AR q X406 03 0.4 MPa setting w t e r Option/Semi-standard: Select one each for a to f. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F = x m g (N) 1. Calculation of applied lateral load F The lateral load F equals the coefficient between the work piece and the conveyor. Thus, from the total amount of the work piece and coefficient of friction, F = x m g (N) 2.
Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F = x m g (N) 1. Calculation of applied lateral load F The lateral load F equals the coefficient between the work piece and the conveyor. Thus, from the total amount of the work piece and coefficient of friction, F = x m g (N) 2.
Black .016 F-2815-161 Grey .020 F-2815-201 Blue .025 F-2815-251 Brown .030 F-2815-301 Beige .040 F-2815-401 Rust