SMC Corporation of America
Elite Part Number Search
Search Results "SS5V2-W16CD-03D-C6"

Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, CIRCULAR CONN., VALVE, SS5V2 MANIFOLD SV2000, UN, SS5V2 BUILT IN FITTING 1/4), 1.65346 lb

Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, FLAT CABLE CONN, VALVE, SS5V2 MANIFOLD SV2000, US, SS5V2 BUILT IN FITTING 1/4), 2.64554 lb, Model1, 5, 34, 2 (P,EA,EB)(A,B)bCvbCvSS5V2-16C10C82.30.280.502.70.180.56

Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, D-SUB CONNECTOR, VALVE, SS5V2 MANIFOLD SV2000, US, SS5V2 BUILT IN FITTING 1/4), 1.43161 lb, Model1, 5, 34, 2 (P,EA,EB)(A,B)bCvbCvSS5V2-16C10C82.30.280.502.70.180.56

Please contact us for the latest version.sales@ocaire.com SS5V2 MANIFOLD SV2000. MFLD, PLUG-IN, D-SUB CONNECTOR. VALVE. SS5V2 BUILT IN FITTING 1/4). 1.41095 lb. UN.

Model: 10S (Side Ported), SI Unit Specification: VB (CC-Link, 16 Outputs, M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 3 Stations, P, E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: 0 (w/o SI Unit), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 3 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: Direct Mounting, DIN Rail Option: DIN Rail Mounting, w/DIN Rail, Combination Manifold:

SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block COM: +COM, Stations: 3 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D (DIN Rail Mounting)

SI Unit: QW (DeviceNet), Input Block Stations: 82 (8 Stations/M12: 4 Inputs), Input Block COM: +COM, Stations: 3 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: None, US Option: X160US (Preferred US Option for DeviceNet Type)

Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 3 Stations, P, E Port Entry: D (D Side 2~10 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting: D0 (DIN Rail Mount w/o DIN Rail)

Common: N (-COM), Connector Mounting Position: D Side, Valve Stations: 3 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot Type: Standard Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting), Voltage Specification: 24VDC

Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 3 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)

Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 3 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D (DIN Rail Mounting)

Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 3 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)

Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 3 Stations, SUP/EXH Block Mounting: D Side 2~10 Stations, Pilot: Internal Pilot, A, B Port: ø6 One-touch Fitting, Mounting Method: DIN Rail Mount w/o DIN Rail

Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 3 Stations, SUP/EXH Block Mounting: D Side 2~10 Stations, Pilot: Internal Pilot, A, B Port: ø6 One-touch Fitting, Mounting Method: DIN Rail Mounting

Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Side Direction, Stations: 3 Stations, SUP/EXH Block Mounting: D Side 2~10 Stations, Pilot: Internal Pilot, A, B Port: ø6 One-touch Fitting, Mounting Method: DIN Rail Mount w/o DIN Rail

Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Side Direction, Stations: 3 Stations, SUP/EXH Block Mounting: D Side 2~10 Stations, Pilot: Internal Pilot, A, B Port: ø6 One-touch Fitting, Mounting Method: DIN Rail Mounting

Type of Connector: D-sub Connector 25 Pin, Connector Outlet Direction: Connector Top Direction, Stations: 3 Stations, SUP/EXH Block Mounting: D Side 2~10 Stations, Pilot: Internal Pilot, A, B Port: ø6 One-touch Fitting, Mounting Method: DIN Rail Mounting

Common: -COM, Connector Mounting Position: D Side, Valve Stations: 3 Stations, SUP/EXH Block Mounting: D Side 2~10 Stations, Pilot Type: Standard Internal Pilot, A, B Port Size: ø6 One-touch Fitting, Voltage Specification: 24VDC