0 Steel wire NBR Steel wire NBR XT010-20 XT010-21 XT041-1 4-16-6 Series VS3135/3145 Dimensions VS3135/3145 V100 SY SYJ VK VZ VT 3-Port size VP 4-Q Mounting hole 3-Q Mounting hole VG VP S070 VQ VS3135 VKF VQZ VZ Q Terminal dimensions Port size Rc VS A Model B C D E F G H J K L M N P R S T U VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 VFN 1 4, 3 8, 1 2 64 64 65 70 1 136 35 9 64 54 19
90 5 90 10 180 10 90 5 90 10 180 10 90 5 90 10 180 10 90 5 Air (Non-lube) Fluid 1.05 1.5 Proof pressure (MPa) 5 to 60C Ambient and fluid temperature 0.15 to 0.7 0.2 to 0.7 0.15 to 1.0 Operating pressure range (MPa) Rotation time adjustment range (sec/90) 0.07 to 0.3 Allowable radial load 40 N 50 N 60 N 20 N 30 N 60 N 80 N 15 N Shaft load Allowable thrust load 2 15 N 30 N 40 N 10 N Allowable
(Displays 0 when the value is (Displays 0 when the value is below 10 L/min) below 20 L/min) 20 to 1050 L/min 40 to 2100 L/min 2.0 0 to 2%F.S. (Displays 0 when the value is (Displays 0 when the value is below 20 L/min) below 40 L/min) 30 to 1050 L/min 60 to 2100 L/min 3.0 0 to 3%F.S.
Frequency (Hz), Remote controller IZS40 IZS41 IZS42 Remote controller Remote controller 0 1 2 3 4 5 6 7 8 9 1 3 1 0.1 5 3 0.5 8 5 1 10 10 3 15 15 5 20 20 10 30 30 15 DC+ DC+ 20 DC DC 30 Set when remote controller is used. 429 IZS40/41/42 Series Wiring Circuit/IZS41, 42 NPN specification Shield Ionizer (IZS41, 42) Green F.G. Ground with a ground resistance of 100 or less.
22 G1/2 32 H (44) H 31.5 25 C C J G1/2 J Dimensions [mm] Model A B C D E F M P Q Grommet: G Grommet: GS Conduit: C Flat terminal: F DIN terminal: D Terminal: T G H G H G H G H G H J G H J XSA1-1P(N) 30 30 66 30 11 20 8 1/8 19 27 56.5 30 43 47.5 50.5 23 56.5 64.5 48.5 52.5 99.5 50.5 68.5 XSA2-2P(N) 36 36 79 35 14 22 10 1/4 24 29.5 68.5 32.5 55 50 62.5 25.5 68.5 67 60.5 55 102 62.5 71 XSA3
C 10 20 30 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-6 Cooling capacity *The Radiating water flow rate of 1L/min is for reference. Radiating water Temp.20 Ambient Temp.20 Fluid water 1000 Cooling capacity W 5 Radiating water flow rate L/min 800 1 3 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp.
When the inlet pressure is shut off and released, the check valve w opens and the pressure in the diaphragm chamber q is released to the inlet side (Figure 2). This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e pushes down the diaphragm.
When the inlet pressure is shut off and released, the check valve w opens and the pressure in the diaphragm chamber q is released to the inlet side (Figure 2). This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e pushes down the diaphragm.
to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 12 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.
speed mm/s Piston speed mm/s 4 CY1F/m1 5 CY1F/m2 6 CY1F/m3 7 CY1F/m4 30 30 30 30 20 20 20 20 CY1F25 CY1F25 CY1F25 CY1F25 10 10 10 10 CY1F15 CY1F15 CY1F15 5 5 5 5 Load mass kg Load mass kg Load mass kg Load mass kg 4 4 4 4 3 3 3 3 CY1F15 CY1F10 CY1F10 CY1F10 2 2 2 2 CY1F10 1 1 1 1 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 Piston speed mm/s Piston speed mm
(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 ASG22F-M5 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 M5 x 0.8 6, 10, 16, 20 R1/8 20, 25, 32 R1/4 20, 25, 32, 40 R3/8 40, 50, 63 R1/2 63, 80, 100 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure 0.1 MPa Ambient and fluid temperature 5 to 60C (No freezing) Number of needle rotations 10 turns
For details, refer to pages 3-7-19 and 3-7-20.
DKeyway dimensions l b D (g6) D (g6) DD (h9) Port size Rc Model Model A B C F H J K S U W BA BB G M N UU L CA CB 20M8 x 1.25 Depth 8 144 (177) CRA1BW50 CRA1BS50 1/8 62 48 46 15 2.5 36 5 98 17 17 8.5 8.5 13 15 11 20 15 118 14 25 5 0 0.030 25 M10 x 1.5 Depth 12 163 (201.5) CRA1BW63 CRA1BS63 1/8 76 60 57 17 2.5 41 5 117 19.5 20 10 10 14 17 13 22 17 139 16 30 6 0 0.030 30 M12 x 1.75 Depth 13
DKeyway dimensions l b D (g6) D (g6) DD (h9) Port size Rc Model Model A B C F H J K S U W BA BB G M N UU L CA CB 20M8 x 1.25 Depth 8 144 (177) CRA1BW50 CRA1BS50 1/8 62 48 46 15 2.5 36 5 98 17 17 8.5 8.5 13 15 11 20 15 118 14 25 5 0 0.030 25 M10 x 1.5 Depth 12 163 (201.5) CRA1BW63 CRA1BS63 1/8 76 60 57 17 2.5 41 5 117 19.5 20 10 10 14 17 13 22 17 139 16 30 6 0 0.030 30 M12 x 1.75 Depth 13
10 to 70C Size Applicable cylinder Nominal thread size 20 For 20 M8 x 1.25 32 For 25 M10 x 1.25 For 32 M10 x 1.25 40 For 40 M14 x 1.5 Dimensions M, P D M E F C G A B H Standard Pneumatic: Up to 0.7 MPa [mm] Model Connection thread M A B C D E mF G Width across flats H Maximum thread depth P Weight JT20 M8 x 1.25 19.2 8 11 (25.4) 23 10 13.6 22 9.5 22 g JT32 M10 x 1.25 23 10 13.4 (30.6) 28
Blow Velocity Distribution (Supply Pressure: 0.3 MPa) qEnergy saving static neutralization nozzle IZN10E-01 wHigh flow rate nozzle IZN10E-02 0 0 100 100 Distance [mm] Distance [mm] 200 200 4 m/s 14 m/s 300 300 11 m/s 3 m/s 400 400 8 m/s 2 m/s 500 30 30 20 10 0 10 20 500 30 30 20 10 0 10 20 Distance (Horizontal) [mm] Distance (Horizontal) [mm] 8 IZN10E Series Flow Rate Characteristics qEnergy
Input of set value Use the or buttons to set the flow value that will output 5 V (10 V) or 20 mA. The entered flow value can be in the range: 10% of the max. rated flow, to the upper display limit. Return to function selection mode. Press the S button to set.
L/min 20 to 2000 L/min Instantaneous flow 10 to 1050 L/min 20 to 2100 L/min Set flow rate range 2 Flow specifications Accumulated flow 0 to 9,999,999,990 L Instantaneous flow 1 L/min 2 L/min Lowest configurable increment Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.)
(mm) Applicable fitting size d 3.2 L Weight (g) D A M Model Urethane Soft nylon Applicable tubing KAR23-04 9.6 4 33.5 34.5 36.5 18.5 18.5 17.5 18 15.5 3.4 2.9 2.0 1.8 5 KAR04-06 KAR04-08 5.6 5.6 6 8 10.4 4 16 12.8 KAR04-10 39.5 37 39.5 10 3.3 2.5 KAR06-08 8 18.5 KAR06-10 6 12.8 KAR06-12 42 4.7 12 20 17 10 3.0 13.1 13.1 Applicable fitting size d 8 KAR08-10 41 4.0 18.0 18.0 10 20 18.5 15.2