VC (1) Fluid temperature (C) 10 to 60 (No freezing) 10 to 100 Dusttight, Low jetproof (equivalent to IP65) Enclosure VDW Environment Location without corrosive or explosive gases VQ Valve leakage (cm3/min) 0 (with oil pressure) Mounting orientation Unrestricted VX2 (3) 30/150 or less Vibration/Impact resistance (m/s2) 24, 12 VDC, 100, 110, 200, 220, 230 VAC (50/60 Hz) 100, 200, 220, 230
100 R 1/2 Elbow type AS121F-U10/32 AS131F-U10/32 6, 10, 16, 20 10-32 UNF AS221F-N01 AS231F-N01 20, 25, 32 NPT 1/8 AS221F-N02 AS231F-N02 20, 25, 32, 40 NPT 1/4 AS AS321F-N02 AS331F-N02 40, 50, 63 NPT 1/4 AS321F-N03 AS331F-N03 40, 50, 63 NPT 3/8 ASP AS421F-N04 AS431F-N04 63, 80, 100 NPT 1/2 ASN Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually differentiated
1 (Edition 3.14) Volume 3 (Edition 1.13) Version 1.1 Port Class A Communication speed 100 Mbps*2 10/100 Mbps*2 (Automatic negotiation) 100 Mbps*2 125/250/500 kbps 230.4 kbps (COM3) Configuration file*3 ESI file EDS file GSDML file EDS file IODD file I/O occupation area Input 20 bytes Output 36 bytes Input 36 bytes Output 36 bytes Input 36 bytes Output 36 bytes Input 4, 10, 20 bytes Output
Normally open Grommet, Grommet terminal Conduit terminal DIN terminal Grommet, DIN terminal Electrical entry VNB01V VNB02V VNH 12 (P1) 10 (P2) Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, Other voltage (Semi-standard) 24 V, Other voltage (Semi-standard) 15% to +10% of rated voltage VND DC Air operated Allowable voltage fluctuation Temperature rise 1 2 1 2 VCC 50C or less (When rated
System Error If the error can not be reset after the above measures are taken, then please contact SMC. -54NO.TQ1050188-OM002 Specification Specifications Rated pressure range 100 to -100 kPa Set pressure range 105 to -105 kPa Proof pressure 500 kPa Smallest settable increment 0.1 kPa Applicable fluid Air Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (Protected against reverse
An over current (1) Check if there is noise Incorrect internal data processing of the product (Er0, 4, 6, 7, 8 or 9) error (Er1, 2) is displayed. interference (such as static electricity. (2) Check if the power supply voltage System error is in the range 24 VDC 10%. (Er0, 4, 6, 7, 8 or 9) is displayed. (2) Supply power in the range 24 VDC 10%.
Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) GWP: 20887 Refrigerant charge [oz (g)] 13.7 0.4 (390 10) 18.7 0.4 (530 10) 22.2 0.4 (630 10) 27.5 0.4 (780 10) Auto drain Float type (Normally open, Min. operating pressure: 14.5 psi (0.1 MPa)) Port size Symbol N NPT1 NPT1 1/2 NPT2 Symbol Nil R1 R1 1/2 R2 Drain tube O.D.
200 100 100 500 400 300 200 100 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa 3000 3000 2000 2000 160 140 1000 1000 700 800 900 700 800 900 125 Load weight: m(kg) Load weight: m(kg) 600 600 160 500 500 400 400 140 320 125 300 300 200 200 280 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 7
-SS5V1-10 10-SS5V2-10 10-SS5V3-10 10-SS5V4-10 Note) The values are for individually operated 2 position type manifold bases with 5 stations.
psig (0.0034 to 0.07 MPa) 1 to 30 psig (0.007 to 0.2 MPa) 5 to 100 psig (0.034 to 0.7 MPa) 15 to 200 psig (0.1 to 1.4 MPa) 15 to 300 psig (0.1 to 2.1 MPa) No code P 01 02 10 20 30 Connections (Inletq, Outletw) 3) Panel mounting hole: dia. 1.42 inch (36.1 mm).
(mm) +0.2 0.1 +0.2 0.1 1.6 0.1 0.1 Tolerance Basic diameter 1 0.5 1.5 0.8 0.8 1.2 0.5 Thickness (mm) 0.1 0.05 0.15 0.08 0.15 0.08 0.12 0.05 Tolerance 10 m 20 m 50 m Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bundle 100 m 50 Ft. (16 m) 100 Ft. (33 m) 2 m Straight
pulse) REA Power supply voltage 100V AC ( 20%), 50/60Hz 24V DC ( 10%) (Power ripple 10% or less) Between case and AC line: 1500V AC for 1min.
Clamping block Fulcrum L Bore size: 50 Bore size: 63 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 250 300 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 250 300 Allowable load mass [kg] Allowable load mass [kg] 15 15 105 30 30, 45, 60 105 90 120 120 75 90 45, 60 75 Arm opening angle: 135 Arm opening angle: 135 Distance to the center of gravity [mm] Distance to the center of gravity [mm] Bore
100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 5) Supply pressure: 0.4 MPa Flow rate consumption: 316 L/min (ANR) 6) Supply pressure: 0.5 MPa Flow rate consumption: 390 L/min (ANR) 200 200 2 s 150 150 1.5 s 100 100 50 50 0.5 s 1 s 1.5 s 0.5 s 1 s 50 50 100 100 150 150 200 200 1500 0 150 300 450
Female threads Rod end threads JIS class 2 Thread tolerance +1.4 0mm (+0.06in) 0 Stroke length tolerance Basic type Mounting brackets Through hole/Double end tapped Mounting Symbol Standard Strokes Double acting: Single rod 1in = 25.4mm Standard strokes (mm) Bore size (mm) 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300 180, 200 Manufacture of intermediate strokes Intermediate
x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 12 x 10 10 x 8 19 x 16 12 x 10 19 x 16 12 x 10 25 x 22 19 x 16 25 x 22 19 x 16 Tubing O.D.
100 100 50 50 0 0 0 5 m/s m/s 19 4-3.
connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)
9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018-10-MT 0.8 80 0.7 70 Circulating fluid pressure [MPa] 0.6 60 0.5 Pump head [m] Available area 50 0.4 Outlet60Hz 40 0.3 30 Outlet50Hz 0.2 20 Return port 0.1 10 Available area 0.0 0 0 5 10 15 20 25 5 Circulating fluid flow [L/min] Fig 9.6-3 Pump capacity(HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT) 9.6.4 HRS012--20-T, HRS018
01, 23, 03, 04, 06, 07 500 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.