Speed: 100mm/sec b. Tubings length (form valve): 50cm below c. Supply Pressure: 0.5MPa (for both brake and driving purposes) d.

D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

VFR VP450 VP470 VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 82 (3 position: 98.5) 129 VZS 71(95.5) VFS 139.5 B A B A VS4 VQ7 (External pilot port) 1/8 (External pilot port) 1/8 EVS VFN A B B A B B B A EA P EB P EA EB ( ): Port size 3/4, 1 Dimensions: Port

Auto Switches/Proper Mounting Position at Stroke End Detection B A (mm) D-A9, D-A9V (mm) D-M9, D-M9V (mm) D-F9W, D-F9WV A A A B B B Operating range Operating range Operating range Nominal size 16 25 Nominal size 16 25 Nominal size 16 25 3 44 116 48 112 48 112 8 8.5 3.5 54 156 58 152 58 152 Auto Switch Mounting When mounting the auto switches, they should be inserted into the actuators switch

C D A B (mm) D-A9, D-A9V (mm) D-F9, D-F9V (mm) D-F9W, D-F9WV A A A B B B Bore size 16 25 32 Operating range Bore size 16 25 40 Operating range Bore size 16 25 40 Operating range 54 106 58 102 57 103 54 156 58 152 57 153 11 8.5 8.5 85 245 89 241 88 242 (mm) (mm) (mm) C C C D D D Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range Bore size 16 25 32 Operating range 27 133

mounting dimensions A (Port size) Y W C B Q V K OUT OUT IN IN Z Plate thickness AR20(K)-B to AR30(K)-B: Max. 3.5 AR40(K)-B : Max. 5 R F P2 S (Pressure gauge port size) Bracket (Option) U M J D T N AR50(K)-B/AR60(K)-B 2 x P1 A (Port size) B Q C K OUT IN R F P2 S (Pressure gauge port size) Bracket (Option) T N J M D U 75 Regulator AR10-A Series Regulator AR20-B to AR60-B Series Regulator with

Enter in order starting from the first station on the D side.

1 (A) 2 (B) 1 (A) 2 (B) 1 (A) 10 (P2) Manual override VNA11 VNA12 12 (P1) 12 (P1) External pilot solenoid 1 (A) 2 (B) 2 (B) 1 (A) 17-4-7 4 Series VNA Port size 6A, 8A, 10A Applicable cable O.D. 6 to 8 (D.T) 125 (Conduit terminal: T DIN terminal: D) 108.2 (Grommet terminal: E) 106.7 (Grommet: G) 63 (Air operated) Pilot port (Back side P2) Manual override Courtesy of Steven Engineering, Inc

2.11-21 D-J79C MHR Grommet 2.11-22 D-F59/F5P/J51/J59 MHK 2.11-23 D-S991/S992/D-S99V1/S99V2 Solid state switch 2.11-23 D-T991/T992/D-T99V1/T99V2 MHS 2.11-23 D-S9P1/S9P2/D-S9PV1/S9PV2 Grommet 2.11-24 D-S791/S792 2.11-24 D-T791/T792 Direct mounting 2.11-24 D-S7P1/S7P2 MHC2 Connector 2.11-24 D-T791C/T792C MHT2 D-F9N/F9P/F9B D-F9NV/F9PV/F9BV D-Y59A/Y59B/Y7P D-Y69A/Y69B/Y7PV 2.11-25 Grommet MHY2

Auto Switch Proper Mounting Position (mm) (mm) Auto Switch Mounting Height D-M9 D-M9W D-M9 D-M9W D-A9 Auto switch model Auto switch model D-A9 B A B A Bore size Bore size 20 25 32 40 Hs 30.5 59.5 34 55.5 20 25 32 40 Note) The above values are a guide in the stroke end detection of the mounting positions of the auto switch.

CE2 ML2B ML1C Mounting Position (Stroke End)/Reed Switch Mounting Position (Stroke End)/Solid State Switch D-E73A (L), D-E76A (L), D-E80A (L) D-M5B (L), D-M5N (L), D-M5P (L) D-M5BW (L), D-M5NW (L), D-M5PW (L) D-M5NTL, D-M5PTL REA REC RHC MTS CC Lead wire clamp/Lead wire cap (option) Series Lead wire clamp Lead wire cap ML1C LC-01 LP-01 Unit: mm Lead wire clamp/Lead wire cap (option) 25 32

A G i 2 x P Port size G A 2 x P Port size b B Conduit DIN terminal D F Q S Cable 6 to 12 G1/2 F Q 280 D G1/2 45 (42) (44) 31.5 Built-in full-wave rectifier type R C C R E J J E 2 x M depth 5 H 2 x M depth 5 B B1 H G A G A B B1 2 x P Port size 2 x P Port size Bracket mounting hole a1 (VXS23, 25) a a1 (VXS24, 26) 6.5 10.5 Dimensions (mm) Model Port size P A B B1 C D E F G H J M Bracket mounting

D-A5/A6, D-A59W Tie rod mounting D-G3/K3 Band mounting Solid state swich D-F5/J5, D-F5NT, D-F5W/J59W, D-F5BA, D-F5F Tie rod mounting 1.10-1 Air Cylinder/Standard Series CS1 Lube, Non-lube: 125, 140, 160, 180, 200, 250, 300 Air-hydro: 125, 140, 160 How to Order CS1 L 300 160 JR Rod boot/Cushion Rod boot Mounting J K N R H Nylon tarpaulin Heat resistant tarpaulin No cushion With cushion on

(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.

A A B C D E F A B C D A B C D A B C D A B C D Tubing O.D. PA 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 2 3 4 1/8" 1/8" PAX 1/8" 1/8" PB 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" Note) For each body class, the second and later numbers or symbols indicate reducing.

6.2 2.5 depth 5 PF2M7mW-m1/2(-L) A D 58 48 18 OUT1 OUT2 10.2 DC() DC(+) 1.4 46.9 (Max. 53.9) 38.5 (30.9) 3 C 18 2 x 3.4 Width across flats B 2 x Port size Port size: 1, 2 OUT IN 68 [mm] 28 Model A C B D P PF2M705/710/725/750W -01(-L) 86.2 11 14 18.2 2.8 depth 8.4 PF2M705/710/725/750W -N1(-L) 86.2 12 14 18.2 2.8 depth 8.4 8 PF2M705/710/725/750W -F1(-L) 86.2 13 14 18.2 2.8 depth 8.4 2 x P

-06-B 10-/21-AW60K-B 142.1 174.1 176.1 261.1 93.9 122.1 154.1 156.1 241.1 91.4 Dimensions B B B B Optional specifications Standard specifications Model Round type pressure gauge Bracket mounting size Panel mount Q R S T U V W Y Z F J K BB CC H J M N 10-/21-AW20K-B 10-/21-AW30K-B 10-/21-AW40K-B 10-/21-AW40K-06-B 10-/21-AW60K-B P1 P2 A B C Note) D E 6 7 7 7 14 19 21 21 28.5 38.5 42.5 42.5

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide