AL.01 Contact output 3 function ALM Contact output 3 operation B Selected for contact output 3 AL.01 5.2 Function HRS Series 5-6 HRX-OM-R005 Chapter 5 Display and setting of various functions 5.3 Main screen 5.3.1 Main screen Displays the current temperature and the set temperature of the circulating fluid.
Setting of the selected alarm Setting range: AL.01 to AL.51 to 63. Press the [MENU] key once. Returns to the main display (which shows the circulating fluid temperature).
220-01-F 220-02 220-02-F 320-03 (02) 320-03-F (02) 420-04 420-04-F 121F-M3 131F-M3 121F-M5 (U10, 32) 131F-M5 (U10, 32) 221F-01 231F-01 2211F-01-06 221F-02 231F-02 321F-03 (02) 331F-03 (02) 421F-04 431F-04 1000F 2000F 2050F 3000F 4000F 1001F 2001F 2051F 3001F 4001F 230F 330F 430F 530F 630F 330F 430F 530F 630F Manifold regulator 4-, 5-port solenoid valve VQ Directional control valves 0 1000
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,
Electrical entry q Description 01 02 03 01 02 03 01 02 03 Mounting bolt and gasket are not included. Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]
Dimensions/Socket (S) Male thread type A2 A1 T D H L1 L2 (mm) A1 A2 Effective area mm L2 Body size H Width across flats T Connection male thread Minimum bore Model D Weight g When When L1 connected connected KKH3S-01MS R1/8 33.5 20.4 20.4 6 36 18.2 14 1/8 40 37.5 KKH3S-02MS R1/4 31.5 19.5 21.1 9 34 KKH4S-01MS R1/8 54.1 50.4 46.4 48.8 22.9 6 50.1 KKH4S-02MS R1/4 54.7 51 19 45 45.4 38.9 9 48.7
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: -