Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø4 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
1 CG1 @2@3@4@5 14B MB Locking at rod end C95 CA1 CS1 Manual release non-locking style: L Material Note Component Parts Material Note Component Parts No. q w e r t y No. !7 !8 !
D(Finger closing port) M5 x 0.8 (Finger closing port) M5 x 0.8 20Auto switch mounting groove (4 locations) 4-M6 x 1 (Piston rod and rack screw) Width across flats 10 (4 locations) Closed E 4-M5 x 0.8 through Open F (Thread for mounting attachment) (mm) A B C D E F G H 40 70 90 J 98 152 192 Model MHL2-16D MHL2-16D1 MHL2-16D2 45 75 95 60 90 110 28 58 78 68 110 130 98 170 210 128 200 240 26
(mm) Type Port size Model 4 M5 x 0.8 M-5AN-4 Barb fitting for nylon tube 6 M-5AN-6 Internal Construction Component Parts q w e r t y e w q Material No.
How to calculate the load energy Moment of inertia and rotation time 2 t E = I2, = 1 2 0.006 0.005 Moment of inertia (kgm2) E: Kinetic energy.(J) I: Moment of inertia...(kgm2) : Angular velocity.(rad/s) : Rotation angle.(rad) 180 = 3.14rad t: Rotation time.
2 is not energized, the valve element A t connected to the piston u is closed by the return spring i. Then valve element B y connected to the valve element A t is open. When the pilot operated solenoid valve !2 is energized, the pilot air supplied to the bottom of the piston u moves upward to open the valve element A t and closes the valve element B y. Because rod !
LED LED OFF IP NS EtherNet/IP IP OFF MS EtherNet/IP LED 10Mbps P2-100 EtherNet/IP 100Mbps / P2-L/A / / / 10Mbps P1-100 EtherNet/IP 100Mbps / P1-L/A / / / -29No.JXC-OMT0001CN-C 4.4. 1 2DIN -30No.JXC-OMT0001CN-C 4.5 (1) DIN (A) (M5 4 ) (M5)X4 () (b) DIN (DIN ) DIN M5X8DIN 2 4 (:3.0[Nm]) M5X8 (M5X14)1 DIN 2 2 :3.0[Nm] DIN () A DIN B M5X14 M5X14) DIN (:
0 w e Valve Valve spring Return spring Spool spring Head cover r Spool valve assembly NBR ZDC !1 Stainless steel t ADC End cover Metallic plated !2 Stainless steel y POM Piston !
Only for D, U, T mounting types Pivot bracket is shipped together with the product, but not assembled. Auto switch Rod end bracket Nil Without auto switch Nil None V Single knuckle joint W Double knuckle joint For applicable auto switches, refer to the table below. Type Not available for 80 and 100. Mounting bracket is shipped together with the product, but not assembled.
Body Size: 10, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: M5, Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: RZ (R + Z)
Body Size: 10, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: M5, Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Non-rotating accuracy Built-in T-slots Non-rotating accuracy Bore size (mm) 40 63 100 0.08 T-slots are provided on 3 faces of the body (except port face), allowing mounting for various brackets.
Contents 9.4 Cooling capacity . 9-9 9.4.1 HRR010-A -10. 9-9 9.4.2 HRR010-W-10. 9-9 9.4.3 HRR010-A -20. 9-10 9.4.4 HRR010-W-20. 9-10 9.5 Heating capacity . 9-11 9.5.1 HRR010-A-10. 9-11 9.5.2 HRR010-W-10. 9-11 9.5.3 HRR010-A-20. 9-12 9.5.4 HRR010-W-20. 9-12 9.6 Pump capacity. 9-13 9.6.1 HRR010-A/W-10 . 9-13 9.6.2 HRR010-A/W-10-T1 . 9-13 9.7 Required facility water flow (for water-cooled type
to 230VAC HRS150-W-20R8-5 40 (4 cores x 8mm2) (60Hz) *including ground HRS100-A-40HRS100-W-403phase 380 to 415VAC 30 M5 HRS150-A-40(50/60Hz) HRS150-W-404 cores x AWG10 3phase HRS100-A-4620 R5.5-5 (4 cores x 5.5mm2) HRS100-W-46380 to 415VAC *including ground (50/60Hz) 3phase HRS150-A-46460 to 480VAC HRS150-W-46(60Hz) *1: A specified earth leakage breaker is installed for option B [Earth leakage
9.4.15 HRL200-W-40-T2 CH1 .9-19 9.4.16 HRL100/200-W-40-T2 CH2 .9-19 9.5 Pump Capacity . 9-20 9.5.1 HRL100-A/W-40 CH1 .9-20 9.5.2 HRL200-A/W-40 CH1 .9-20 9.5.3 HRL300-A-40 CH1 .9-21 9.5.4 HRL-A/W-40 CH2 .9-21 9.5.5 HRL100/200/300-A/W-40-T2 CH1 .9-22 9.5.6 HRL300-A-40-T3 CH2 .9-22 9.6 Types of Hazard Labels . 9-23 9.6.1 Positions of danger warning label .9-24 9.7 Standards . 9-25 9.8 Daily
16 LEFS 25 LEFS 32 50 8 20 8 6 12 6 W(kg) W(kg) W(kg) W(kg) 40 5 5 W(kg) 10 W(kg) 15 30 8 16 10 16 10 10 20 6 12 5 12 10 4 2 0 0 0 100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 0 100 200 300 400 500 600 V (mm/s) LEFS 16 LEFS 25 LEFS 32 50 12 20 W(kg) W(kg) 10 W(kg) W(kg) W(kg) W(kg) 6 40 6 15 8 30 8 6 8 10 5 5 20 4 5 12 10 16 10 12 16 10 2 0
20-HRSH090-W-4014 Facility water temperature: 32 oC 12 Cooling capacity [kW] Facility water temperature: 40 oC 10 8 6 4 2 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [] Fig. 9-7 Cooling capacity(HRSH090-W-20-HRSH090-W-40-) HRSH Series 9.4 Cooling capacity 9-11 HRX-OM-R026 Chapter 9 Documents Pump capacity 9.4.4 HRSH090-A-20/40-HRSH090-W-20/400.6 60 Circulating fluid pressure [MPa