SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-V-P-A2L-W"

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -

Hysteresis Note 4) Variable from 0 Protection Short circuit protection Switch output Output type Voltage output: 1 to 5 V, Current output: 4 to 20 mA Voltage output Output impedance: Approx. 1 kW Maximum load impedance at power supply voltage 24 V: 600 W, at power supply voltage 12 V: 300 W Minimum load impedance: 50 W Response time Note 6) Linked with the response time of the switch output

P kit F kit T kit PS (Side entry) FS (Side entry) Note 1) S kit is composed of a flat cable housing assembly (AXT1002PU20) of q SI unit and w P kit (20 pin).

No 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 5 V, 12 V 12 V 2-wire 3-wire (NPN equivalent) IC circuit A96V A96 5 V Grommet A93V A90V A93 A90 100 V IC circuit Relay, PLC 2-wire 12 V 24 V 100 V or less Solid state auto switches marked with are produced upon receipt of order.

DC (42 mA), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA)

DC2410% Power [W] Note8),9) Max. 86 Max. 109 Type Note10) Non-excitation-operated type specification Lock unit Holding force [N] 47 78 157 294 75 108 216 421 Power consumption [W] Note9) 5 5 Powre supply voltage [V] DC2410% Note1HorizontalUse an external guide (external guide friction coefficient: 0.1 or less).

2 VQ5250 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5351 (A) 4 (B) 2 VQ5350 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 VQ5451 VQ5450 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5551 (A) 4 (B) 2 VQ5550 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Parts list Parts list Description Material Note No. 1 2 3 Description Material Note No. 1 2 3 Body

(REFRIGERANT) IDFA60-23 W R 0001 (2018 4 ) W R 0001 o 1 Z 12 o P Q R A Z 1 2 3 4 W X y Z 2018 2019 2020 2021 IDFA60/70/80/90 Series 1-4 IDX-OM-W094 1.3 HFC 1-4 IDFA60/70/80/90 Series 1-5 IDX-OM-W094 1.4 / 1 1.5 () IDFA60/70/80/90 Series 1-6 IDX-OM-W094 2 2.1 IN OUT (ONOFF ) 6-4 6-4 L N PE 3-5 IDFA60/70/80/90 Series 2-1 IDX-OM-W094 () IDFA60/70/80/90 Series 2-2 IDX-OM-W094 3

L L+A Fig. 1 Fig. 2 L 2 1 V E = W ( ) 2 1000 Collision speed V = 1.4 Va Find the kinetic energy E (J) of the load. 1 420 E = 1 ( ) = 0.088 2 1000 V = 1.4 x 300 = 420 Correction factor (reference value) Find the allowable kinetic energy Ea (J).

Models M-F9(V), F9W(V), J51, G5NB and all models of PNP output switches do not have built-in short circuit prevention circuits. If loads are short circuited, the switches will be instantly damaged. Use caution to avoid reverse wiring with the brown power supply line and the black output line on 3 -wire type switches. 2.

Note 2) Refer to p.5.3-5 for lead wire length.

IC circuit 5 V, 12 V 3-wire (PNP) Relay, PLC 2-wire 12 V Grommet 5 V, 12 V 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) A93L 5 mZ (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-10-22 for details.

7 p. 7 Communication plug connector for IO-Link JXC-CD-T JXC-CD-S Straight type JXC-CL-S Straight type T-branch type (Accessory) To SI To ENC To SI To MOT To PWR Provided by customer Communication cable Power supply for controller 24 VDC (3 m) p. 7 Power supply plug p. 7 (Accessory) Options Conversion cable1 Controller setting kit Teaching box p. 7 p. 7 P5062-5 (0.3 m) (With 3 m cable) LEC-T1

Lead wire length* (m) Load voltage Auto switch model Electrical entry Indicator Wiring (Output) 3 (L) 5 (Z) Applicable load Special function Style 0.5 () (N) AC DC P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P C76 IC circuit P P P P P p p p P p p p p p p p P P P P P P P P 3 wire (Equiv. to NPN) 5V Yes C73 100V 12V Relay PLC C80 IC circuit No 100V

Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .

[W] at 20 Note6) 6.3 7.9 7.9 Rated voltage [V] 24VDC 0-10% Note 1) The maximum value of the horizontal workload.

Core wire colors M12 48 1 1 2 3 4 5 2 : DRAIN 6 5 Red: V+ Black: V 16 White: CAN H Blue: CAN L M12 4 3 14.9 Socket connector pin arrangement Connections Terminal no.

[1] Power supply input terminals, L1, L2: Provide specified power supply to input terminals L1 and L2. [2] Connect the motor input terminal (U, V, W) to the driver power terminal (U, V, W).

12 V Coil rated voltage DC S070 10% of rated voltage Allowable voltage fluctuation (A) 2 Class B or equivalent Coil insulation type VQ Power consumption (Current) 0.5 W (21 mA) 1 W (42 mA) 1.5 W (63 mA) 1 (P) 3 (R) DC VKF Grommet Plug-in, L plug connector, M plug connector (With light/surge voltage suppressor) Electrical entry Normally open VQZ (A) 2 Note 1) Based on JIS B 8374-1993.