Use to connect tubes at right angles. P. 6 KJY P. 4 KJL P. 8 KJR Gasket/10-32 UNF seal on thread Part no.: M-10/32G Material: Stainless steel 304, NBR Precautions Be sure to read before handling.
(kPa) 5 m, 10 m 25 m 50 m, 100 m Viscosity Conversion Table Kinematic viscosity (mm2/sec) (cSt) 400 High 200 100 50 20 1 Low 1 Fluid indicator Water, Coolant (water-soluble), Cleaning fluid Equivalent to honey Coolant (oil-based) 100 200 300 400 500 FGF1 Paint 300 600 900 1200 1500 FGF3 35 58 85 90 95 100 Flow coefficient (%) 500 1000 1500 2000 2500 FGF5 These relationships between fluids
Z M J H G F N Model MXF8-10 58 49.5 49 21 22 13.5 20 4 MXF8-20 63 54.5 54 26 26 14.5 26 4 MXF8-30 78 69.5 69 41 40 14.5 26 6 8-6-10 11 Low Profile Slide Table Series MXF Dimensions: MXF12 Stroke adjuster at extension end Stroke adjuster at retraction end Width across hexagon socket hole 2.5 MX Width across flats 7 N 2 ( 1) x 25 Blanking plug (M-5P 2 points) Possible to use as operating
Panel adapter B ZS-22-02 Output specifications 0 1 NPN (2 outputs) PNP (2 outputs) Specifications Model PFW300-m PFW301-m PFW310-m PFW311-m PFW321-m PFW320-m 0.5 to 4l/min (0.02 to 0.14SCFM) [Setting is 0.6 to 4l/min (0.02 to 0.14SCFM)] 0.05l/min (0.002SCFM) 5 to 40l/min (0.18 to 1.41SCFM) 2 to 16l/min (0.07 to 0.56SCFM) Flow rate range measurement and setting Minimum setting unit 0.5l/min
Standard 7 in. (0.18 m) 5 in. (0.13 m) 3) Not available with SH material.
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude For the product operation at an altitude of 1800 meters, the cooling capacity at an altitude of 1800 meters = 8.4 Cooling capacity x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
and case) Withstand voltage 10 to 60C Ambient temperature Enclosure IEC60529 Standard IP67 Lead Wire Lead wire length indication (Example) D-M9BW L Lead wire length Nil M L Z 0.5 m 1 m 3 m 5 m Note 1) Lead wire length Z: 5 m Applicable auto switches Solid state auto switch: Manufactured upon receipt of order as standard.
Then gradually open the valve at inlet side to supply gas to the regulator. 2) Close the valves on the inlet and outlet side and hold for at least 10 minutes. Then confirm the outlet pressure. 3) Rotate the adjustment wheel clockwise (INCR) until the outlet pressure reaches the outlet pressure setting. Then hold for at least 10 minutes and confirm the outlet pressure.
Recommended valve/for PB1013 air operated type: SYJ34 Note 2) After initial suction of liquid operating at 1 to 7Hz, it can be used with operation at lower cycles.
Reduced apparent power 10 VA m 7 VA (Size 1) Normally Closed (N.C.)
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10.5 M3 x 0.5 10 M5 x 0.8 11.5 M4 x 0.7 16 M6 x 1.0 13.5 M5 x 0.8 20 M8 x 1.25 16.5 M6 x 1.0 25 M10 x 1.25 22.5 M8 x 1.25 28 M14 x 1.5 Clevis pin part numbers d m m l Dd9 t L t Applicable bore size (mm) Applicable snap ring Part no.
10 mA (2 V or less at 40 mA) Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .
5.0 kg *1 Depth 160 mm Rc2 Face to Face 170 mm Improved Nominal Filtration Rating AFF 1 m (Current model: 3 m) AM 0.1 m (Current model: 0.3 m) *1 For AFF/AM/AMD90 CAT.ES30-17B AFF/AM/AMD Series Compressed Air Preparation Filter AFF/AM/AMD Series Variations A model with 11.0 m3/min flow capacity (Size 80D) has been newly added.
Standard condition: Flow rate converted to a volume at 20C and 101.3 kPa (absolute pressure) Normal condition: Flow rate converted to a volume at 0C and 101.3 kPa (absolute pressure) Response time The response time can be selected to suit the application.
This saves additional electrical wiring at the time of installation.
Recommended valve/for PB1013 air operated type: SYJ34 Note 2) After initial suction of liquid operating at 1 to 7Hz, it can be used with operation at lower cycles.
Recommended valve/for PB1013 air operated type: SYJ34 Note 2) After initial suction of liquid operating at 1 to 7Hz, it can be used with operation at lower cycles.
Detection nozzle: 1.5 Detection nozzle piping: F type 4 x 2.5 tube 1 m, 3 m, 5 m/G, H type 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa Test conditions ISA3-F ISA3-G 300 60 3 m 1 m 250 50 5 m 1 m 5 m Displayed value Displayed value 200 40 3 m 150 30 100 20 50 10 0 0 0.3 0.25 0.2 0.15 0.1 0.05 0 0.06 0.05 0.04 0.03 0.02 0.01 0 Actual distance [mm] Actual distance [mm] ISA3-H 500 450 3
Ordering example) Lead wire length 5A 10 ZS ZCU Lead wire length (For DC) Nil 6 10 15 20 25 30 0.3 m (Standard) 4A 20 VJ10 6 AMJ 0.6 m 1 m 1.5 m 2 m 2.5 m 3 m Note) If ordering a vacuum switch with 3 m lead wire, specify both the vacuum unit switch and the 3 m lead wire connector part numbers. Nil 30 50 0.6 m 3 m 5 m (For 100 VAC) 1A 36 VJ10 6 Misc. ZX1051-K15LOZ-EC 1 pc.