Body Style: B (Base Mounted w/Screws), Coil Voltage: 5 (24VDC), Flow Rate: D (Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011), Electrical Entry: C (Plug Lead w/Light/Surge Suppressor), Port Size: w/o Sub-plate, Made to Order: X50 (Universal Type)
Body Style: B (Base Mounted w/Screws), Coil Voltage: S (5 VDC), Flow Rate: A (Power Consumption: 0.35W, Operating Press: 0.1MPa, Cv: 0.016), Electrical Entry: G (Grommet), Port Size: w/o Sub-plate, Made to Order: X50 (Universal Type)
Body Style: B (Base Mounted w/Screws), Coil Voltage: S (5 VDC), Flow Rate: C (Power Consumption: 0.5W, Operating Press: 0.3MPa, Cv: 0.016), Electrical Entry: C (Plug Lead w/Light/Surge Suppressor), Port Size: w/o Sub-plate, Made to Order: X50 (Universal Type)
Body Style: B (Base Mounted w/Screws), Coil Voltage: V (6 VDC), Flow Rate: D (Power Consumption: 0.5W, Operating Press: 0.5MPa, Cv: 0.011), Electrical Entry: C (Plug Lead w/Light/Surge Suppressor), Port Size: M5 (Base Mounted, w/Sub-plate)
Body Style: B (Base Mounted w/Screws), Coil Voltage: 5 (24VDC), Flow Rate: B (Power Consumption: 0.35W, Operating Press: 0.3MPa, Cv: 0.011), Electrical Entry: C (Plug Lead w/Light/Surge Suppressor), Port Size: w/o Sub-plate, Made to Order: X62 (Normally Open Type)
Body Style: B (Base Mounted w/Screws), Coil Voltage: 5 (24VDC), Flow Rate: A (Power Consumption: 0.35W, Operating Press: 0.1MPa, Cv: 0.016), Electrical Entry: G (Grommet), Port Size: w/o Sub-plate, Made to Order: X50 (Universal Type)
Body Style: B (Base Mounted w/Screws), Coil Voltage: 5 (24VDC), Flow Rate: A (Power Consumption: 0.35W, Operating Press: 0.1MPa, Cv: 0.016), Electrical Entry: CO (Plug Lead w/Light/Surge Suppressor without connector), Port Size: w/o Sub-plate, Made to Order: X50 (Universal Type)
A functional earth cable must be connected to the M3 terminal. If this product is connected using power cables that are more than 30m long or go outside of a building then external protection devices should be added to protect against electrical surge damage.
M3 x 5 L OUT1 [Default setting] OUT2 Both OUT1 and OUT2 Model: ZS-28-B Power and output lead wire with connector Operator Bracket Lever LCD display All of the settings are completed, and the controller will return to measurement mode.
B AC (83) C A B -16No.PF-OMO0004CN-E 0.450.55 Nm ,, (ZS-33-M) (ZS-33-MS) M34 (84) M3 M3 -17No.PF-OMO0004CN-E M3(2) 0.350.45 Nm (84) M3 DIN DINDIN DIN0.350.45 Nm () DIN DIN F02(G/14)DIN DIN -18No.PF-OMO0004CN-E IN8cm 2F.S.
Bracket mounting Mount the bracket using the mounting screws (M3 x 15 L) suppllied. The required tightening torque is 0.320.02 Nm. L-type bracket (Through hole) Mounting screw (M3 x 15 L) Mounting screw (M3 x 5 L) CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Display color: Green (7) Input terminal block (M3 terminal block) Input terminal block for temporary stop signal or cascade trigger signal. Electrical specifications: Photo coupler (8) Output terminal block (M3 terminal block) Output terminal block for cascade trigger signal. Electrical Standard: O/C DC5V 25mA or less (9) Dip switch for setting cascade or temporary stop.
Operating Conditions Model : ML2B32 Load : 15N Speed , Va : 0.25m/s Pressure : 0.5MPa L1 : 0.05m L2 : 0.05m W W L1 L1 Loading Static Loading Dynamic Loading A Load due to W W3 B Momentum due to W M2 C Momentum due to we when stopping M3 V D M1 V 2.
position, tighten the M3 mounting screw to secure the auto switch by making the bottom face of auto switch attached to the cylinder tube.
As the indicator LED protrudes from the switch unit, mounting the switch bracket above the LED may cause damage to it. (4) Insert the auto switch mounting screw (M3) included in accessories from the mounting hole of the auto switch mounting band, inserting the through hole of the switch bracket.
position, tighten the M3 mounting screw to secure the auto switch by making the bottom face of auto switch attached to the cylinder tube.
position, tighten the M3 mounting screw to secure the auto switch by making the bottom face of auto switch attached to the cylinder tube.
Use the attached mounting screw (M3 x 0.5 x 14) for mounting. The mounting screw (M3 x 0.5 x 7) attached to the digital pressure switch assembly will not be required.
Pressure Control Equipment O-ring Cross recessed round head screws (with SW) (M3) End block Tie-rod For common supply blocks, reversible and double-sided mounting is available. Common supply tie-rod Industrial Filters Cross recessed round head screws (with SW) (M3) Tightening torque: 0.32 0.03 Nm 451 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 4 4.
3 Order 1 piece of finger assembly per one unit. 12-10-10 10 180 Angular Style Air Gripper Cam Style Series MHY2 Dimensions MHY2-10D Pin hole positioning 30 9 9 2-M3 x 0.5 thread depth 4 (Mounting hole) 4 4-M3 x 0.5 MHZ 3H9 + 0.025 0 depth 3 (Thread for mounting attachment) 6 0.005 0.025 MHF 4 4-M3 x 0.5 thread depth 6 (Mounting hole) MHL 3 6 2-3.4 2M3 x 0.5 thread depth 6 12 MHR (Mounting