L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 5 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 2 to 200 L/min 1 to 1 L/min 10 to 1000 L/min 3 to 3 L/min 20 to 2000 L/min Power supply voltage 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% Temperature characteristics 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) (25C standard)
bolt CUJB4-4 -6 -8 -10 CUJB6-4 -6 -8 -10 -15 CUJB8-4 -6 -8 -10 -15 -20 CUJB10-4 -6 -8 -10 -15 -20 Model Mounting bolt CUJB4-4 -6 -8 -10 CUJB6-4 -6 -8 -10 -15 CUJB8-4 -6 -8 -10 -15 -20 CUJB10-4 -6 -8 -10 -15 -20 C D A M2.5 x 21l M2.5 x 23l M2.5 x 25l M2.5 x 27l M3 x 22l M3 x 24l M3 x 26l M3 x 28l M3 x 33l M3 x 22l M3 x 24l M3 x 26l M3 x 28l M3 x 33l M3 x 38l M3 x 22l M3 x 24l M3 x 26l M3
NBR FKM KA00809 KA00725 Quantity 1 1 1A-P85 4D-P85 FNR100N-10 1.1 L Rc1 Stainless steel 304 FNR100V-10 FNR101N-10 FNR101V-10 Model Tank capacity Port size 1.8 L KA00809 4 O-ring Industrial Filters Replacement Procedure Actuators Modular F.R.L.
NBR FKM KA00809 KA00725 Quantity 1 1 1A-P85 4D-P85 FNR100N-10 1.1 L Rc1 Stainless steel 304 FNR100V-10 FNR101N-10 FNR101V-10 Model Tank capacity Port size 1.8 L KA00809 4 O-ring Industrial Filters Replacement Procedure Actuators Modular F.R.L.
5 33 6 28 2.5 6 40 34 45 4.6 6 CY1S15-Z 7.5 9.5 16.6 38 6.5 28 29.5 20.5 15 20.5 M4 x 0.7 M5 x 0.8 10.5 16.5 5.4 12 2 5 6 52 39 11 60 5.8 28 40 8 CY1S20-Z M6 x 1 M6 x 1 10 9.5 21.6 44 8.5 36 37.5 24 19 20 10.5 22 5.4 16 2 5.5 8 45 16 70 28 62 5.8 46 10 CY1S25-Z M6 x 1 M6 x 1 10 26.4 52 8.5 40.5 40.5 27.5 21.5 21 12.5 22 11 6.5 16 5.5 53 20 49 2 8 70 70 54 7 10 CY1S32-Z M8 x 1.25 M8 x 1.25
10 10 5 4 3 4 5 3 4 5 3 2 2 2 1 1 1 1 5 10 20 10 5 1 20 30 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) Transfer speed (m/min) Lever-type weight of transferred object and transfer speed graphs (graphs (2) and (3)) show the values at room temperature (20 to 25C).
fitting size 8 10 12 Only R is available.
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
Range Resolution LAT3-10 0 to 10 Refer to the 0.03 LAT3-20 0 to 20 Area Range table on the LAT3-30 0 to 30 right. LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds the 0.5 to 5.0 set value.
Contact protection box CD-P11 LED Brown OUT Brown Choke coil Resistor Reed switch Zener diode Surge absorber OUT Blue Blue Weight (g) D-A73 D-A72 D-A73 D-A80 Auto switch model 10 10 10 0.5 Lead wire length (m) 47 47 47 3 LED Brown OUT (+) Brown Contact protection box CD-P11 CD-P12 77 5 Resistor Reed switch Zener diode Dimensions OUT () Blue Blue Indicator light D-A80 without indicator
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
25 18.5 23.5 27.5 26 30 33 34.5 37 39.5 8 15.3 21.1 25.5 15.8 22.3 26.7 23.5 27.9 29.4 30.8 32 36.2 8 10 14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 D1 4 17 4 4 10.4 19.7 L2 A D2 10 H 8 Connection threads 6 18.5 10 10 12.8 21.8 (R) 10 (R) Applicable tubing 8 15.2 20.5 26 18 12 25.3 M L1 10 18.5 23 41 29 28.4 17 17 12 20.9 24 58 46 30.4 D1 22 Reference dimension for R threads after
An example is shown below. direction + direction direction + direction 0 5 10 [mm] 0 5 10 [mm] This example shows the Target Position set at 10 mm. The table of the Card Motor moves to 10 mm from the origin position. 11.5 Relative positioning The Target Position is determined based on the current position.
-06-06-08 ZH13DS-08-10-10 ZH13DL-08-10-10 ZH15DS-10-12-12 ZH15DL-10-12-12 12.8 6 24 21 7.8 6 17 24 12.8 6 24 21 6 17 24 12.8 6 24 22 6 17 24 12.8 6 24 22 6 17 24 13.7 6 26 24.5 8 20 28 13.7 6 26 24.5 8 20 28 15.3 10 28 27 10 22 30 15.3 10 28 27 10 22 30 Applicable tubing diameter J 7.8 7.8 7.8 9.6 9.6 10.7 10.7 ZH ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,
) 24VDC (10%) 24VDC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 24VDC (10%) 100 to 240VAC (10%) Power consumption 20VA or less 10W or less 20VA or less 10W or less 20VA or less 10W or less 10W or less 20VA or less Between case and AC line: 1500VAC for 1 min.
0 90 Vacuum pressure reached 80 kPa Vacuum pressure in tank [kPa] 80 Vacuum pressure [kPa] 66 kPa 70 60 53 kPa 50 40 kPa 40 26 kPa 30 20 13 kPa 10 0 Suction flow rate [L/min (ANR)] 10 0 20 30 40 50 60 70 80 90 100 1 10 Time to reach vacuum [s] 1 0 2 3 4 5 6 7 8 9 10 11 12 Vacuum Break Flow Rate Characteristics*1 (Representative value) *1 Silencer exhaust specification The graph shows the
Load Weight Allowable Moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
10 9 32 2 2.5 3 20 25 30 23 23 22 21 21 20 19 18 16 15 2) Using the cylinder body installed vertically: To operate the rotary cylinder with the cylinder body installed vertically, the total load that is applied to the tip of the piston rod must be within the thrust of the rectilinear portion in which the load ratio is taken into consideration. 1.5 15 1 0.4 0.5 0.6 0.7 10 (Refer to page 11
-580 IZS4-640 IZS4-820 IZS4-1120 IZS4-1300 IZS4-1600 IZS4-1900 IZS4-2320 IZS4-2500 Part no. n 5 6 7 9 10 13 18 21 26 31 38 41 Applicable tube O.D.