CN1: Power supply plug . 22 5.1 Power supply plug specifications . 22 5.2 Electric wire specifications . 22 5.3 Wiring of power supply plug . 23 (1) Wiring of the power supply . 23 (2) Wiring of the stop switch . 23 (3) Wiring of the lock release . 24 5.4 Stop circuits . 25 (1) Example circuit 1 Single controller with teaching Box . 25 (2) Example circuit 2 multiple controllers . 26 (3) Example
AF F F E E B C AR Cross spacer E: 4 x Rc F: Without thread E D A AL A 23 B 16 C 14 D 25 Applicable model AC10 Model Y14-M5 Y24-01 Y24-02 Y34-01 Y34-02 Y44-02 Y44-03 Y54-03 Y54-04 Port size M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 AW AC20 40 40 22 40 AG AC25, AC30 49 43 28 48 AV AC40 60 48 36 54 AF800 AF900 Caution on Mounting AC40-06 72 62 40 62 1.
port Pilot air operated cyinder driving mechanism Two types of seal material (NBR, FKM) 1 port 2 port Metal seal with poppet valve structure 2-port 3-port 3 port Variations Orifice diameter [mm] Rated voltage Flow-rate characteristics Av x 106 [m2] ( ): Cv Port Pressure specifications Port size Model 13 12 13 12 SGH(A)12-7010 SGH(A)22-7015 SGH(A)32-7020 SGH(A)42-7025 SGH(A)13-3010 SGH(A)23
The Parameter is then enabled. 23 - 5.3.4 The recommended parameters for each actuator The recommended parameters for each actuator. Please change the parameter values in accordance with the user specification. Refer to LECSB Operation Manual, section 5 for details.
ONOFF ON-OFF ON (23 ) "digit" () 0 () SI ONOFF ON -12NO.ZK2-OM00801-B A ON (23 ) (OUT1) "" (23 ) () 5%R.D.(5%) "()" () "F" () -13NO.ZK2-OM00801-B ,FG (Assy) No.
Operating environment .23 5-6. Lubrication .23 6. Maintenance or inspection .23 6-1. Maintenance or inspection .23 6-2. Replacement part .24 6-3. Maintenance .24 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
(P2) 12(P1) a,b 12(P1),23(P2) (2) a 12(P1) 1(P)2(A)3 3(R) 3(R) b 23(P2) 2(A) 2(A)3(R)1 1(P) 1(P) 12(P1) 1 2 3 23(P2) 4 5 6 7 8 POM 9 -12No.VEX-OMY0001 () () 3(R) 2(A) 1(P) 1(P) 2(A) 3(R) () a b P1P2 2(A) 1(P) -13No.VEX-OMY0001 (7) (1) (2) (3) (4) (5) (6) (12) (7) (8) () (9) (5) (6) (14) (10) (P2) (5) (4) (11) (4) (13) DCAC (7) 14 No.VEX-OMY0001
Series VXZ22/23 Bronze NBR FKM N.C.
Kit includes items 21, 22, 23 and 24 from the table above. MHZA6-PS Seal kits consist of items 21, 22, 23 and 24 in one kit, and can be ordered using the seal kit number.
Work piece mounting reference plane Rc 1/4 Vacuum suction port Rc 1/4 Vacuum suction port 80 Stroke + 115 (table movement range) 7.5 194 (249) 41 46 58 2-T-slot 1 57 65 69 90 95 9.3 44 40 (T-slot pitch) 2-T-slot 2 Stroke + 350 (405) 17 28 23 (78) 40 36 Body mounting reference plane 3-5H10 depth 5 3.3 5.8 1.7 5.3 T-slot 1 dimensions (switch groove) 11.5 45 27 (82) 40 80 Stroke + 145 9.4 4.5
A 136 136 Long Stroke Slide Table MXW Series Specifications Specifications MXW8 MXW16 MXW20 MXW12 MXW25 Model 8 x 2 11 or its equivalent 12 x 2 17 or its equivalent 16 x 2 23 or its equivalent 20 x 2 28 or its equivalent 25 x 2 35 or its equivalent Bore size(mm) Rc(PT)1/8 M5 x 0.8 Port size Air Fluid Double acting Action 22~102psi {0.15~0.7 MPa} Operating pressure 152psi {1.05 MPa} Proof
22 7 4 11 MXH16, 20 (16, 20) 20 6 21 17 2 1 19 5 18 18 8 10 4 7 22 23 13 24 3 12 11 Parts list Parts list Description Material Note Description Material No.
to 131) Ambient temperature C (F) 5 to 50 (23 to 122) 5 to 55 (23 to 131) 5 to 50 (23 to 122) Outlet air atmospheric pressure dew point C (F) Standard performance 20 (-4) Inlet air flow rate l/min (ANR) (SCFM) Note 2) 625 (22.0) 62 (2.19) 125 (4.41) 250 (8.82) 375 (13.24) Outlet air flow rate l/min (ANR) (SCFM) 50 (1.8) 100 (3.5) 200 (7.1) 300 (10.6) 500 (1.77) Purge air flow rate l/min
Refer to p.1.0-23 and 1.0-24 for further information.
Table 3.9-1 Function codes NO Code Name Function 1 04(04h) read holding registers Reading multiple registers 2 06(06h) preset single register Writing registers1 3 16(10h) preset multiple registers Writing multiple registers 4 23(17h) read/write 4x registers Reading/writing multiple registers 1Broadcast is not supported.
Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height [mm] Auto switch model Auto switch model D-M9m(V) D-M9mW(V) D-M9mA(V) D-M9m D-M9mW D-M9mA D-M9mV D-M9mWV D-M9mAV Bore size Bore size A B 20 4 8.5 25 4.5 9 32 4.5 9.5 40 7 12 Hs1 Hs2 Hs1, Hs2 Hs1 Hs2 20 16.5 17 17 23 17 25 19 19.5 19.5 25.5 19.5 32 22.5 23 23 29 23 40 26.5 27 27 32.5 27 * Adjust the auto switch after confirming
p. 17 Specifications VCooling Capacity Calculation Air-cooled Refrigeration (Single-phase 200 to 230 VAC) p. 18 Required Cooling Capacity Calculation pp. 39, 40 Water-cooled Refrigeration (Single-phase 200 to 230 VAC) p. 19 Precautions on Cooling Capacity Calculation p. 40 Circulating Fluid Typical Physical Property Values p. 40 Cooling Capacity pp. 20, 21 Heating Capacity pp. 22, 23
CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able
Series C76: 32, 40 Operating pressure Mounting style Maximum stroke that can be used according to buckling strength 100.0 Nominal symbol C76 Mounting bracket diagram 32 40 (MPa) Lateral load applied to the rod end fR (N) Foot: L Rod side flange: F Head side flange: G 0.3 58 54 10.0 L C7640 44 0.5 40 W W W F 36 0.7 33 C7632 24 0.3 23 G 17 0.5 16 1.0 13 0.7 13 Clevis: C, D Rod side trunnion
(mm) D H Bore size B GA L LB GC GB C A LX LH MM NB Y X NA Z S LD 3.5 through, 6.5 depth of counterbore 4 9.5 28 8 M4 x 0.7 12 4 8 31.5 85 65 10 15 12 14 16 5 11 20 23 16 4.5 through, 8 depth of counterbore 5 5 9.5 16 15 18.3 20 16 5 11 20 26 20 8 28 M5 x 0.8 10 16 31.5 86 66 Specific Product Precautions Be sure to read before handling. Caution on mounting Caution 1.