SMC Corporation of America
Elite Part Number Search
Search Results "AS2201FG-01-08A"

NPN 1 output ISE30A-01-N-ML Digital pressure PNP 1 output ISE30A-01-P-ML NPN 1 output/ Voltage output ISE30A-01-C-ML switch Note 3) NPN 1 output/ Current output ISE30A-01-D-ML Note 1) This is an assembly of the bracket and resin panel nut. Note 2) l in part numbers for a round type pressure gauge indicates a type of connection thread.

lOre mentioned above 8'8 1 00 same as standard port locatIon C95 Standard part number l-xC3 j B f@] Location 01 pons and cushion val\les On rod cover and head CO\lfH.

Number of Ports: 2 Port, Piping Direct., Plunger Length: 0 (Side Ported, Long), Body Option: Side Mounting, Port Size: N01 (NPT 1/8, Side Ported Only), Actuator Type: 08 (Toggle Lever), Suffix: None, Indicator: None, Bracket: B (w/Bracket)

Number of Ports: 2 Port, Body Option: Side Mounting, Port Size: N02 (NPT 1/4), Actuator Type: 08 (Toggle Lever), Suffix: None, Bracket: B (w/Bracket)

Number of Ports: 2 Port, Body Option: Side Mounting, Port Size: 02 (R 1/4), Actuator Type: 08 (Toggle Lever), Suffix: None, Bracket: B (w/Bracket)

Number of Ports: 3 Port, Body Option: Side Mounting, Port Size: N02 (NPT 1/4), Actuator Type: 08 (Toggle Lever), Suffix: None, Bracket: B (w/Bracket)

Number of Ports: 3 Port, Body Option: Side Mounting, Port Size: 02 (R 1/4), Actuator Type: 08 (Toggle Lever), Suffix: None, Bracket: B (w/Bracket)

Pipe Port Type: NPT, Rod Arm Type: -, Mounting Method: Side, Plunger Type: -, Body Shape: Block Vertical Type, Number of Ports: 2-Port, Push Button Type: -, Plumbing Type & Direction: Direct Side, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Toggle Switches, Nominal Designation of Piping Thread: 1/8, Valve Flow Coefficient (Cv)(mm2): 2.03, Suffix for indicator

Pipe Port Type: NPT, Rod Arm Type: -, Mounting Method: Side, Plunger Type: -, Body Shape: Block Vertical Type, Number of Ports: 3-Port, Push Button Type: -, Plumbing Type & Direction: Direct Side, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Toggle Switches, Nominal Designation of Piping Thread: 1/8, Valve Flow Coefficient (Cv)(mm2): 2.03, Suffix for indicator

Pipe Port Type: Rc (R), Rod Arm Type: -, Mounting Method: Side, Plunger Type: -, Body Shape: Block Vertical Type, Number of Ports: 2-Port, Push Button Type: -, Plumbing Type & Direction: Direct Side, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Toggle Switches, Nominal Designation of Piping Thread: 1/4, Valve Flow Coefficient (Cv)(mm2): 16.06, Bracket option

Pipe Port Type: NPT, Rod Arm Type: -, Mounting Method: Side, Plunger Type: -, Body Shape: Block Vertical Type, Number of Ports: 2-Port, Push Button Type: -, Plumbing Type & Direction: Direct Side, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Toggle Switches, Nominal Designation of Piping Thread: 1/4, Valve Flow Coefficient (Cv)(mm2): 16.06, Bracket option

Pipe Port Type: NPT, Rod Arm Type: -, Mounting Method: Side, Plunger Type: -, Body Shape: Block Vertical Type, Number of Ports: 3-Port, Push Button Type: -, Plumbing Type & Direction: Direct Side, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Toggle Switches, Nominal Designation of Piping Thread: 1/4, Valve Flow Coefficient (Cv)(mm2): 16.06, Bracket option

Number of Ports: 3 Port, Body Option: Side Mounting, Port Size: R 1/4, Actuator Type: Toggle Lever, Suffix: None, Bracket: w/Bracket

Number of Ports: 3 Port, Piping Direct., Plunger Length: 0 (Side Ported, Long), Body Option: Side Mounting, Port Size: N01 (NPT 1/8, Side Ported Only), Actuator Type: 08 (Toggle Lever), Suffix: None, Indicator: None, Bracket: B (w/Bracket)

PC44 0 Specifica tion of alarm No . 00 : No specif ication (The optimum item is recorded according to the alarms that have occurred ea rlier and operating conditions.) 01 to FFh : Specifica tion (The specified item is recorded when an alarm of the specified alarm No. occurs.)

AC-OMX0051-D PRODUCT NAME Air Combination MODEL / Series / Product Number AC20(A)-(F,N)01~(F,N)02(C,E,E1,E2,E3,E4,G,M)-(1,2,3,6,C,J,N,R,Z,ZA)-D AC20B,C,D -(F,N)01~(F,N)02(C,E,E1,E2,E3,E4,G,M)-(1,2,6,C,J,N,R,Z,ZA)-D AC30(A)-(F,N)02~(F,N)03(C,D,E,E1,E2,E3,E4,G,M)-(1,2,3,6,8,J,N,R,W,Z,ZA)-D AC30B,C,D -(F,N)02~(F,N)03(C,D,E,E1,E2,E3,E4,G,M)-(1,2,6,8,J,N,R,W,Z,ZA)-D AC40(A)-(F,N)02~(F,N)04(C,D

Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5

Bore size With One-touch fitting U01 U02 U03 U04 1 8 1 4 3 8 1 2 Needle Valve/Flow Characteristics AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01 AS2201F-02, AS2211F-02 AS2301F-02, AS2311F-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) Number of needle rotations Number of needle rotations AS3201F, AS3211F

Millimeter Inch With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 01 03 05 07 09 11 4 6 8 10 12 04 06 08 10 12 Thread _ Meter thread (M5) Unified thread (10-32 UNF) R(PT) N NPT Port size M5 X 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AS ASN AQ ASV Needle Valve/Flow Characteristics AK ASD230F ASD330F ASD430F ASS 100 200 400 1.5 6 3 07, 08, 09, 10, 11 Effective area (mm2) Flow

Also, do not use the filter when these chemicals are present in the atmosphere. 2 Series ZB How to Order Manifold S 01 ZZB 08 M5 Stations Pressure Sensor/Vacuum Pressure Switch Mountable Note) Sensor/switch non-mountable base Sensor/switch mountable base Nil S 01 02 1 station 2 stations Note) Select S when the model with either the pressure sensor or the vacuum pressure switch is selected