200 300 300 5m/s 2m/s 2m/s 400 400 2) Flow rate : 60L/min 5) Flow rate : 60L/min 75 50 25 0 25 50 75 75 50 25 0 25 50 75 -75 -50 -25 0 25 50 75 -75 -50 -25 0 25 50 75 0 0 mm mm ionizer to workpiece [mm] ionizer to workpiece [mm] Installation distance from Installation distance from 200 200 10m/s 400 400 10m/s 5m/s 600 600 5m/s 800 800 2m/s 2m/s 1000 1000 3) Flow rate : 250L/min 6) Flow rate
Without auto switch CRB1B J Size Rotating angle Port location Vane type Shaft type J K S T X Y Z Double shaft (Long shaft without keyway & Four chamfers) Double round shaft Single shaft key Single round shaft Single shaft with four chamfers Double shaft key Double shaft with four chamfers CRB2 CRBU2 CRB1 MSU J Z Y K S T X Key Key CRJ D C D D D D D CRA1 C C C CRQ2 MSQ MRQ C D D DKey 20(mm)
D D D D D CRA1 C C C CRQ2 MSQ MRQ C D D DKey 20(mm) Nominal size C D 50 63 80 100 19.5 39.5 21 45 23.5 53.5 30 65 Note) Dimensions and tolerance of the shaft and keyway are the same as the standard.
A C Reset (Vacuum suspension) (+) White B AC type Lead wire colors 100 VAC, 200 VAC Set (Vacuum generation) Yellow Yellow A COM. Blue Red C SOL. Reset (Vacuum suspension) Gray Gray B Special care must be taken for the latching type. 1. Avoid using this product with a circuit which electrifies both the set and reset signals simultaneously. 2.
C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut
120 250 W = 300 LAT3m-30 4 200 150 200 150 W = 0 W = 100 W = 200 200 150 300 100 W = 0 W = 100 W = 200 3 300 100 600 50 600 50 2 0 0 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 0 5 10 15 20 25 30 Stroke(Positioning distance) St [mm] 1 Operating condition Model: LAT3F-m Mounting orientation: Horizontal/Vertical Step data input version: Takt time entry method (Triangular drive)
Indication Item Setting and selection Setting range Sets the upper temperature limit for circulating fluid SP. +0.1 C to +10.0 C +1.0 C [High] Upper/lower temperature limit (1) High/ Low Sets the lower temperature limit for circulating fluid SP. -0.1 C to -10.0 C -1.0 C [Low] TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within
Standard condition (ANR) and normal condition (NOR) are defined as follows: Standard condition (ANR): 101.3 kPa, 20 C Normal condition (NOR): 101.3 kPa, 0 C Unit selection function The selectable display units are L/min or CFM (ft3/min).
TEMP READY function setting example [1] Circulating fluid temperature at start of operation: about 20 C [2] Circulating fluid setting temperature: 15 C [3] "TEMP READY Bandwidth (Upper Limit)": Set to "2.0 C". [4] "TEMP READY Bandwidth (Lower Limit)": Set to "-2.0 C". [5] "TEMP READY stabilization time": set to "60 sec". [6] "TEMP READY monitoring start time": set to "30 sec". [7] "Time
Male thread Suitable screw torque (Nm) Hexagonal width (mm) Adjustable spanner nominal (mm) 1/4 4.5 M3 M5 10/32-UNF 100 1/6 8 150 7 to 9 14 1/8 200 12 to 14 17 1/4 200 22 to 24 21 3/8 200 28 to 30 24 1/2 1Nm=10.2kgf/cm Tightening torque for lock nuts Caution qSuitable screw torque for a hexagon lock nut is shown in the table below.
300 200 8-8-10 10 Precision Air Slide Table Series MXP Table Accuracy Traveling parallelism C C side parallelism to A side D M D side parallelism to B side B W A Port C MX M MTS B Distance from 0 of gauge dial when guide block is moved to full stroke after body is fixed on a base.
HRSH150/200-A: 2 pcs. are used per unit HRS-S0214 Dust-proof filter (Upper) 1 pc. HRSH100/150/200-A: 2 pcs. are used per unit HRS-S0185 Dust-proof filter 1 pc.
A-A A B B A Auto switch mounting bracket A-A B-B Dust seal band type Seal band holder roller specification C No.
MULTI COUNTER:CEU5 UP M/C COUNT PRESET FUNC. LEFT RIGHT DOWN SEL.
The overall length is longer than the cylinder with air cushion as follows because the bumpers are attached to the both sides of the piston; 32, 40: +6mm, 50, 63: +8mm, 80, 100: +10mm, 125: +12mm 32 40 50 63 80 100 90 90 102 141 145 164 102 124 124 164 200 200 125 235 132 Stroke range (mm) Bore size (mm) Width across flats S ZZ Effective thread length A C B D Ee11 F G H MA MB J K MM N P V
G 0.2 Straight 0.0 20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Operating temperature C Note) Refer to the table Series above, as the tubing length differs depending on each size. 505 FEP Tubing (Fluoropolymer) Metric Size TH Series RoHS Series -20 m roll -100 m roll Metric size TH0402 TH0425 TH0604 TH0806 TH1075 TH1008 TH1209 TH1210 Model Tubing O.D.
200 LX5 + 200 LX3 + 200 LX5 + 200 LX3 + 200 1 2 3 1 2 3 1 2 1 2 1 2 3 to 90 3 to 90 3 to 63 3 to 90 3 to 66 3 to 44 3 to 90 3 to 40 3 to 45 3 to 35 3 to 35 3 to 30 4 2.5 6 4 8 5 10 6.5 12 8 B (Black), W (White), R (Red), BU (Blue), Y (Yellow), G (Green), C (Transparent), YR (Orange) L* is calculated by the number of coils (N) x O.D. 10Clean Series (Example) 10-TCU0425B-1 TUB-11 Polyurethane
Angle adjusting screw Angle adjusting screw Angle adjusting screw n o A R ti n 0 0 n c ot g 9 e 9 o l e y at ir ti y c d a a a io e d w g w ir n j n u y d y ti s ra e e g s ti k k u n n n g j ti of d g of s d a e u ir e e e e j d of c l g a g ti g o n n e n k A n l g n ra ra A e y n n w io io a y at at 9 ot ot 0 R R The rotation range under the adjustment of an angle at 60 is indicated
(Manufacturable stroke range:LEJB40/ 200 to 2000mm, LEJB63/ 300 to 3000mm) Product Weight Series LEJB40 Stroke [mm] 200 300 400 500 600 700 800 900 1000 1200 1500 2000 Weight (kg) 5.7 6.4 7.1 7.7 8.4 9.1 9.8 10.5 11.2 12.6 14.7 18.1 Extra weight of lock (kg) S2:0.2 / S6:0.3 / T6:0.2 Series LEJB63 Stroke [mm] 300 400 500 600 700 800 900 1000 1200 1500 2000 3000 Weight (kg) 11.5 12.7 13.8 15.0