MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install

In the case of mounting auto switch from B direction Step 2) Insert the auto switch into the auto switch installation groove from direction B. A B MHZ MHF Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates.

Insert the switch into the switch case, and install switch holder B into the first groove (MRHQ20/25) or the second groove (MRHQ10/16) and secure the switch.

A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 38 55 MXY8 2.5

8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4.

Solid state switch D-F8 CUJ (As compared with SMC Series CU cylinders without magnet) Dimensions (Without magnet) Series Variations Bore size (mm) A(a) B(b) C(c) Bore size (mm) Rod end configuration Stroke (mm) Clean series 4 6 8 10 15 20 b Action Series Auto switch B Double acting Male thread Without thread None 4 10() 15() 13() 4 Single acting, Spring return 6 13(13) 19(22) 13(33) Double

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.

E Stroke Model Stroke A 100 30 50 75 20 10 100 75 50 30 20 10 8 (5.5) 11.1 (8.6) 13.8 (11.3) 18.7 (16.2) 8 (5.5) 3 (0.5) 11.1 (8.6) MXF8 9.5 10 5 10 27.1 (24.6) 23.8 (21.3) 20.7 (18.2) MXF12 12 29.1 13.1 13.1 44.8 (42.3) 44.2 (41.7) 68.7 (66.2) MXF16 17.2 46.8 25.8 15.8 MXF20 19.4 70.7 46.2 22.7 20.7 Solid State Switch: D-M9B, D-M9P, D-M9N, D-F9W (mm) E A B E Stroke A Model Stroke

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Head Cover Port: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 100mm, Head Cover Port: In-line, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 125mm, Head Cover Port: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 125mm, Head Cover Port: In-line, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 15mm, Head Cover Port: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 150mm, Head Cover Port: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 150mm, Head Cover Port: In-line, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 175mm, Head Cover Port: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 16mm, Stroke: 200mm, Head Cover Port: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -