V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Pressure switch Power supply Thermometer Solenoid valve Equipment for test Control circuit
Symbol (B) 2 (A) 4 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Valve model Port size Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25 0.05 0.07 0.05 0.07 0.19 0.28 0.22 0.27
Table(2) Rated Voltage-Electrical Entry-Electrical Option PAX Table(1) Connection Size and Applicable Model Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G C D, T G, C T PB S L, Z S L, Z S Note ) Connection Applicable model VXP2130-02 VXP2130-03,VXP2140-03 VXP2130-04,VXP2140-04 VXP2150-06
4 mA 4.16 mA 20 mA E F G Voltage output (0 to 10 V) 1 0 V 0.10 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.
Normally closed Normally open Double acting VNA01 VNA02 VNA03 Coil rated voltage (V) AC (50/60 Hz) 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15% to +10% of rated voltage 35C or less (When rated voltage is applied.) 5.6 VA (50 Hz), 5.0 VA (60 Hz) 12 VA (50 Hz), 10.5 VA (60 Hz) 3.4 VA (50 Hz), 2.3 VA (60 Hz) 7.5 VA (50 Hz), 6 VA (60 Hz) DC 12 (P1) 12 (P1) 10 (P2) Allowable
Applicable for strong alkali-based cleaning fluid Suitable for filtering cutting fluids P.57 P.57 P.58 (For coarse filtration) (For coarse filtration) Leg Material: Stainless Steel X47 P.58 54 FGF Series Made to Order Please consult with SMC for details.
wire Connector Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector Relay, PLC 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 5 V, 12 V Grommet 2-wire 12 V Water resistant (2-color indication) With diagnostic output (2-color indication) 5 V, 12 V IC circuit 4-wire (NPN
AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 2 Cuts air consumption by operating the return stroke at a reduced pressure.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
16 10 2 0 0 0 0 100 200 300 400 500 600 V (mm/s) 0 100 200 300 400 500 600 V(mm/s) 0 100 200 300 400 500 600 V(mm/s) -9- (1)(DC24V) LEFS40 (mm) 1) 200, 300, (400), 500, (600) (700), 800, (900), (1000) 50 60 (kg) ) 23 (mm/s) 2) 20500 10250 (mm/s 2) 3,000 (mm) 0.02 (mm) 20 10 (m/s 2) 3) 50/20 () 540 (%) 90 RH ) 56.4 (DC24V) A/B 800 / (V) DC2410% (W) 4) 100 (W) 5) 43 (W) 6) 141 7)
PA IN PAX Solenoid coil PB Coil: Class B, Class H Rated voltage Model AC Standard Option 100 V, 200 V 48 V, 110 V, 220 V, 240 V Orifice size (mm) Model Port size 10 VXD2130 Rc 1 4, 3 8, 1 2 Rc 3 8, 1 2 Rc 3 4 DC 24 V 12 V 15 20 VXD214 VXD215 VXD226 VXD227 VXD238 VXD239 2 0 Standard Option 2 0 2 0 Rc 1 25 Material 2 0 32A 35 40A 40 2 0 Body Seal Brass/BC6, Stainless steel NBR, EPDM, FKM
Connector pin numbers -18No.PS-OMX1005 Internal circuit and wiring examples ZSE20AF---Output specification -N NPN open collector 1 output Max. 28 V, 80 mA Residual voltage 1 V or less -P PNP open collector 1 output Max. 80 mA Residual voltage 1 V or less -A NPN open collector 2 outputs Max. 28 V, 80 mA Residual voltage 1 V or less -B PNP open collector 2 outputs Max. 80 mA Residual voltage
AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.
AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.
Note 2) Value on option V, M (Non-leak, Vacuum). Port A Port P Pilot Pressure Port P (N.O.) Model Pressure (MPa) 0.25 to 0.7 VXA31 4 VXA32 4 Option Material No.
Size 100 125 150 R V Voltage Symbol Voltage 30 3-phase AC200V(50Hz) AC200/220V(60Hz) Option 1 Ventilation direction Option None(Ventilated from back) Ventilated from the right Ventilated from the left Anti-corrosive treatment Option None Symbol Symbol NIL NIL C 1 K 2 P 3 R V Timer type solenoid valve with auto drain Ground fault circuit interrupter Ventilated from the top For medium air pressure
Caution Operation instructions Consult P/A when using solvents other than water.
Real-time switch output Hysteresis mode ON Flow rate conversion YES OFF P-1 P-2 Normal condition {0C, 101.3 kPa, Dry air} or standard condition (ANR) {20C, 101.3 kPa, 65% RH} can be selected.