Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment
4) C6 (One-touch fitting for ?6)W = 19n + 45
4) C6 (One-touch fitting for ?6)W = 19n + 45
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: C6 (6mm), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: C6 (6mm), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with Operation
Series: SY3, Actuation: 1 (2 Position Single), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: R (External Pilot), Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,
Series: SY5, Actuation: 1 (2 Position Single), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: R (w/Surge Voltage Suppressor, Non-polar), Manual Override: D (Push-turn Locking Slotted Type),
Series: SY5, Actuation: 1 (2 Position Single), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber), Pilot Specification: R (External Pilot), Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,
Series: SY5, Actuation: 3 (3 Position Closed Center), Mounting/Porting: 3 (Top Ported), Seal: 1 (Metal), Pilot Specification: R (External Pilot), Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type
Model: 10 (Side Ported), Number of Cores - Lead Wires: L3 (9 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 2 Stations, P, E Port Locations: U (U Side), SUP/EXH Block: R (External Pilot), A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)