Model: 42 (Dual AC), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 15 (15m), Bar Bracket: w/o Bracket, DIN Rail Bracket for Controller &
(mm) Effective orifice(mm 2) Mountiting hole M Weight (g) D L KRE08-00 KRE06-00 17 6 8 10 12 34.8 53.8 72.6 24 KRE12-00 27 22.8 M22 1 23 46.1 99 M14 1 M16 1 15 17 19 20.5 23 18.0 15.5 17 20.8 M20 1 21 38.5 42 46.5 48.5 5.7 19 KRE10-00 24 29.5 Note: Fitting cover ordered separately. 115 Series KRM Flame Resistant One-touch Fittings Manifold Dimensions KRM11 Weight (g) Applicable tube O.D
Simplified Selection Flow Chart Simplified Selection Flow Chart Simplified Selection Flow Chart Single Axis Electric Actuator Series LTF (AC Servomotor) Single Axis Electric Actuator Series LTF (AC Servomotor) Work load kg Maximum speed mm/s Positioning repeatability mm Guide type Motor type Lead screw Series Capacity Brake Ground ball screw 0.02 Standard motor [Tamagawa Seiki Co., Ltd.] 100W 15
(Nm) L(mm) MHM-16D M6x1 5.2 11.5 MHM-25D M8x1.25 12.5 12.4 MHM-32D M10x1.5 24.5 13.5 MHM-50D M12x1.75 42 16 3.
conversion tting) Cooling method A Air-cooled refrigeration Specications Model HRL100-Am-20 HRL200-Am-20 HRL300-Am-20 CH1 CH2 CH1 CH2 CH1 CH2 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 1.4 2.2 3.0 Control method PID control Ambient temperature [C] 2 to 45 Circulating uid CH1: Tap water/CH2: Tap water, Deionized water1 Set temperature range [C] CH1: 15
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
For 115VAC and 230VAC, the allowable voltage fluctuation will be 15% to 5% of rated voltage. The voltage drop will occur due to the internal circuit of S, Z and T types (with energy saving circuits). Allowable voltage fluctuations should be within the range below.
.=5[V]1[V]4[V](1F.S.4[V]10.04[V]) a 1-5V 1-5V 4-20mA (HYS) ON OFF 63% ka () sa 10 L/min 10 L ON OFF ON () OFF () 2 5 5 10 L/min 10550L 14 No.LFE*-OMY0008 sa ON-OFF () 1 L/min 10 11 12 1 L/min () 0 ta (SI )SI LFE ON-OFF () [S/cm](/ 100200S/cm na ON 0 ha 15 No.LFE*-OMY0008 2MPa(69 ) IN ()IN (68 ) DC(-)/ + 2 2 2 20mm 0mm 0mm 0mm 2 2 2 20mm 0mm 0mm 0mm 5 5 5 50mm
No.XL-OMY0002 L // XLD XL-OMY0002 2 11 4 , 2. 2 5 , , , , 33 7 4 9 5 11 6 12 7 13 8 14 9 15 10 16 1 XL-OMY0002 *1) (ISO/IEC)(JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements
MXQ16 MXQ20 MXQ25 1) 2) ( ) 3) 4) / / 2 ,3 ) 2 2 ,3 ) 1) 1 2) 20 ,0.150.6MPa 3) MXQ25(A)-150,MXQ6B-50,75MXQ8B-75,100MXQ16B-100,150MXQ20B-125,150 300mm/s 4) MXQ**B 50200mm/S 1 (MPa) MXQ8(A,C) 0.3 MXQ8B 0.3 MXQ12(A,C) 0.3 MXQ12B 0.3 MXQ16(A) 0.2 MXQ16B 0.2 MXQ20(A) 0.2 MXQ20B 0.2 MXQ25(A) 0.2 5 2. 2-1 ,2 L1 L2 (Nm) (mm) (mm) MXQ6 M40.7 2.1 5 8 MXQ8 M40.7 2.1 8 11 MXQ12 M50.8 4.4 11 15
JXC-OMT0034CN (GW)(CC-Link) / LEC-GMJ2 1. . 4 2. . 6 2.1 . 6 2.2 . 6 2.3 . 7 2.4 () . 8 (1) . 8 (2). 8 (3)(LEC) . 8 (4). 8 (5) . 8 (6) . 9 (7) . 9 3. . 10 3.1 . 10 3.2 . 12 3.3 . 13 (1)(LECGMJ2) . 13 (2)DIN (LECGMJ2D) . 13 3.4 . 14 (1) . 14 (2) . 14 4. . 15 4.1 (STATION NO.,B RATE) . 15 4.2 (CN2SW) . 16 4.3 (LEC) . 17 5. . 19 5.1 CN4 . 19 5.2 CN3 . 19 5.3 CN1CONT . 19 5.4 CN2PC
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
Display (PF2D30/31) 40 Sensort 15 Brown 6 2 Analog output Switch output or Pluse output Main circuit Main circuit Main circuit Main circuit 8 4 Load + 12 to 24VDC White 7 3 Black A 62 52 42 5 1 Blue Model A PF2D5--1 PF2D520 12.7 PF2D504 4-4.5 9.52 Display (PF2D30/31) Sensor Brown 52 1 2 6 Analog output Switch output or Pluse output 4 8 Load + 12 to 24VDC White 3 7 Black 1 5 Blue 18 PF2D5
1 q t i 385 PF2D Series Dimensions: Remote Type Sensor Unit PF2D504-11/520-13 60 70 176 40 15 A Model PF2D504 PF2D520 9.52 12.7 62 52 42 A 4 x 4.5 52 1 18 PF2D540-19 Internal Circuits and Wiring Examples 78 86 186 -1/2 Analog voltage output Analog current output 56 15 Sensor Monitor PF2D3 Black Output for PF2D3 4 8 Switch output Main circuit Main circuit Main circuit Main circuit 3 7 U DC
Inrush current flow time (Reference) 200V Current XLA 100V XL XL XLQ XM XY 0 5 15 10 20 25 30 Time (second) DXSA XVD XGT CYV 459 A XL Series Glossary 1 Shaft Sealing Method 2 Seal Materials Bellows Bellows offer cleaner sealing with reduced particle generation and less outgassing. The two major bellow types are: Formedbellows and Welded-bellows.
Option J: With drain guide Bracket (Option) 1/4B female thread T: With element service indicator Maintenance space HA Drain AT ID AMG AFF Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5
Selection of air quality by purpose For these cases, degree of quality is 15 4 +3 5 specified as 1, 4, and 2 respectively. 40 5 +7 25 Refer to Guide (1). Refer to Guide (2). Refer to Guide (3). Refer to below piping system chart. Refer to Guide (4) page 14-14-4.
Tightening Torque for Piping Size Wrench tightening angle Tightening torque 1 (25A) 10 to 15 50 to 100 Nm Procedure for installing the valve on the tank Connection thread Proper tightening torque [Nm] Rc1/4 12 to 14 Rc3/8 22 to 24 Rc1/2 28 to 30 Rc3/4 28 to 30 Rc1 36 to 38 Rc1 1/2 40 to 42 5.
:l 3/86 female thread Maintenance l--I space ~ Drain H I I Dimensions with mounting bracket Model Port size A B C D E F G I J 1 K 1 L 1 MI N I 01 P I 01 RI s B AMH850 11 /2 , 2 460.5 42 348 220 57.5 220 10 463.51 180 I 30 I 15 I 24 I 13 1120 1184 1 220 1110 1 18 I 6 6 SeriesAMH Made to Order Specifications ICD With Differential Pressure Gauge (GD40-2-01) I@ With IN-OUT Flange For ease of