. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: Vacuum

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: Vacuum

Body/Exhaust Type: Single Unit - Silencer Exhaust, Nominal Nozzle Size: ø0.7, Supply Valve and Release Valve: Self-holding Release Valve Linked / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

Body/Exhaust Type: Single Unit - Silencer Exhaust, Nominal Nozzle Size: ø0.7, Supply Valve and Release Valve: Self-holding Release Valve Linked / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: Vacuum

. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V, Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: Vacuum

. / None, Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V, Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release

Body/Exhaust Type: Single Unit - Silencer Exhaust, Nominal Nozzle Size: ø1.5, Supply Valve and Release Valve: Self-holding Release Valve Linked / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:

Body/Exhaust Type: F (For Manifold - Individual Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L1 (L-type Plug Connector Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)

For vacuum equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www. smcworld.com Nozzle diameter Port size 05 0.5 mm 07 0.7 mm Nil 6 One-touch fitting 01 Rc1/8 female thread Symbol EXH Vacuum pressure reached S 90 kPa L 48 kPa Mounting P V Caution Specifications 1 .

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch

When using seal tape, leave one thread exposed when wrapping fitting or pipe. 0.25 f-t-+-t---t-+--j--+--:--t--+-I Set point -~V '" Q. ::; O Mount vertically. c.> 0.2 :; :2 l' Q. Qi '5 0 ~ 5l :r 0. 31<.-t-~-+---="I--;;::'--t-t_1 Q. 0.15 f-t.,---+t--t-+---1--+-t--t-l 8Tightening torque of mounting screw (M3) for gauge is 3-Skgf . cm.

(Maximum10 stations) Example) IITV00-05-07 2 stations 3 stations 02 03 Indicate part numbers in order starting from the first station on the D side. Note: Due to the common supply/exhaust feature, different pressure range combinations are not available. 10 stations 10 The asterisk () specifies mounting.

Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option