SMC Corporation of America
Elite Part Number Search
Search Results "VVEXB-1-10-01"

How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)

Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -29No.EX-OMN0011-F Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.

Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214

Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan). 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 ) ) ) ) ) ) ) ) Options Symbol Description ) ) Nil 1 B With bracket Built-in silencer (EXH port) Handle / Bonnet material Symbol Material S A B Flame resistant PBT 3 Aluminum Built-in silencer A spacer or spacer with bracket is required if the valve is combined

PSE20 Pressure range 1 For positive pressure For vacuum For low pressure For compound Rated pressure range 0 to 1 MPa 0 to -101 kPa 0 to 101 kPa -101 to 101 kPa Set pressure range -0.1 to 1 MPa 10 to -101 kPa -10 to 101 kPa -101 to 101 kPa Setting/Display resolution 0.1 kPa 0.1 kPa 0.1 kPa 0.001 MPa Power supply voltage 12 to 24 VDC, ripple (pp) 10% or less (Protected against inverse connection

IZE11 Connected sensor Sensor for 0.4 kV Sensor for 20kV Rated measured range -0.4 to +0.4 kV 1 -20 to +20 kV 2 Set min. unit 0.001 kV 0.1 kV Set measurement distance 10 to 50 mm 25 to 75 mm Power supply voltage 24 VDC 10% (Protected against inverse connection) Current consumption 50 mA or less (Except current consumption at sensor) Sensor input 1 to 5 VDC (Input impedance: 1M ) Input number

Non-leak(2) Pressure Vacuum VX32 NBR, FKM, EPDM 1 cm3/min or less 0.1 cm 3/min or less (1) 10 6 Pam 3/s or less VX33 Note 1) Differs depending on the operating conditions such as pressure, etc.

No.EX-OMP0004CN-I SI (CC-Link ) // EX260-SMJ 2 8 9 10 10 11 LED 16 21 26 26 27 28 -1No.EX-OMP0004CN-I (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating

BORE B D GA'GA K MM N P x LD LH H zz h 1 3 8 (35) 2.76 2.05 t52l 0 7 9 l:20) 1.57 1.39 (10) 0.67 M8x1.25 J.2A t7l M18rl 5 1 . 1 4 3 5 4 l90l 1.06 lz7) 1 5 1 o3) 3 5 4 ls0J 2.24 (58) 1188) 2.05 (52) '11.21 2.60 (66) s T o 7 7 2 (196) 1 3 8 (35) 3.35 (85) 2.52 079 (20) 1 5 7 1.39 (10) 0.67 M10x1.25 i.2a l7l M18x1 5 1.22 (31) 3 8 6 l93l 1.34 (341 1.63 (16) 0.45 1 1 1 . 5 ) 1 9 7 t50l 6 5 4 t1661

Abnormal (19 V or less) Output area mapping Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 -45No.EX-OMX1001 Dimensions -46No.EX-OMX1001 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications

M8 Connector Flat Ribbon Cable Manifold Manifold Internal Wiring For more than 10 stations, both poles of the common should be 1. To order connector cable only Cable length(L) Part no. 300mm V100-49-1-1 500mm V100-49-1-2 1000mm V100-49-1-3 2000mm V100-49-1-4 5000mm V100-49-1-7 Flat Ribbon Cable Manifold In the manifold valves, the wiring to the individual valves is wired.

How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.

-01 T inch (mm) L: Dimensions ni Stations L1 (38) 14.57 (370) 1 . 1 (28) ( 1 6 1 ) ( 1 \123) (142) I September 1999 O 1978-1999 SMC Pneumatics, Inc.All Righls Reserved.

-01 T inch (mm) L: Dimensions ni Stations L1 (38) 14.57 (370) 1 . 1 (28) ( 1 6 1 ) ( 1 \123) (142) I September 1999 O 1978-1999 SMC Pneumatics, Inc.All Righls Reserved.

Within 1%F.S. Within 2%F.S. Within 0.75%F.S. Within 1%F.S. Within 0.5%F.S.

10 psig (0.007 to 0.07 MPa) 1 to 30 psig (0.007 to 0.2 MPa) 2 to 60 psig (0.014 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) 5 to 150 psig (0.034 to 1.0 MPa) Code Connections (Inletq, Outletw) Bonnet option 01 02 06 10 15 Code Connections 1/4 inch face seal (Female) 1/4 inch face seal (Male) 3/8 inch face seal (Female) 3/8 inch face seal (Male) 3/8 inch tube weld Code Bonnet Standard Panel

EX140-SMJ1 Applicable system CC-Link Ver.1.10 Occupied station 1 station Station number setting range 1 to 64 (Set with a rotary switch) Communication specification Station type Remote I/O Communication speed 156 k/625 k/2.5 M/5 M/10 Mbps Cable length between stations 20 cm or more Max. cable length 1200/900/400/160/100 m Communication supply voltage 15 to 30 VDC Solenoid supply voltage 24

Example) G36-P4-01-X30 ISA2 ISA2 2 Port Solenoid Valve Regulator PSE VCA27A S 5 DL 02 4 Q AR 20 02 1 B IS Port size Voltage CE compliant 02 02N 02F Rc 1/4 NPT 1/4 G 1/4 Thread type ISG 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Nil N F Rc NPT G ZSM1 Throttle Nil S B K Without throttle and manual lock With throttle With manual lock With manual lock and throttle Semi-standard