Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.
0 Description Main parts Replacement Parts MHT2-32D MHT2-40D MHT2-50D MHT2-63D Finger assembly MH-TA3201 MH-TA4001 MH-TA5001 MH-TA6301 wo Lever assembly MH-TA3202 MH-TA4002 MH-TA5002 MH-TA6302 e <32, 40> weryio Link parts assembly MH-TA3203 MH-TA4003 MH-TA5003 MH-TA6303 <50, 63> werio CDQ2A32-15D CDQ2A40-15D CDQ2A50-20D CDQ2A63-20D Compact cylinder !
Bore size Series CJ2 Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Series MB, CA Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load ratio 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQC1000
) Regulation (EU) No 517/2014 IPCC AR4) R134a 1,430 1,430 R404A 3,922 3,920 R407C 1,774 1,770 R410A 2,088 2,090 (1) (2) 6-3 IDU22E75E A B (G) (D) E (F) C (10, (10 1m) 1m) J K L2 N1 M P 13 4x H (911)[] 911)[] mm A B C D E F G H J K L M N P IDU22E R1 325 775 1153 93 445 1235 279 353 600 379 46 85 IDU37E R11/2 360 1258 64 550 1350 290 388 680 414 50 13 IDU55E 855 1345 1440 R2 470
(Example) 10-TFU0425B-2 TFU0425-2-50 (100)-X3 TFU0425-3-50 (100)-X3 TFU0604-2-50 (100)-X3 TFU0604-3-50 (100)-X3 TFU0805-2-50 (100)-X3 TFU0805-3-50 (100)-X3 2 3 2 3 2 3 4 2.5 6 4 8 5 50m or 100m roll B (Black), W (White), R (Red), BU (Blue), Y (Yellow), G (Green), C (Transparent), YR (Orange) TUB-12 Clean Tubing: Polyolefin Tubing How to Order Designed to be used for blow-off and washing
B 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.34 0.20 4-E 0.34 0.25 0.50 0.25 0.50 0.34 0.53 0.34 0.66 0.41 B Rear screw clearance hole / NC(D)Q8M(Z) (Inch) Symbol Bore E B 056 (9/16") 075 (3/4") 106 (1-1/16") 150 (1-1/2") 200 (2") 250 (2-1/2") 0.34 0.20 4-E 4-E 0.34 0.25 0.50 0.25 0.50 0.34 0.53 0.34 0.66 0.41 B Through screw clearance hole / NC(D)Q8N(Z) (Inch
M L K J H E t W1 W2 M 14 20 25 29 37 49 58 69 89 100 117 136 14.5 20.5 24.5 30.5 36.5 48.5 6 7 7 9 9 10 11 16 21 24 32 41 10 17 22.5 24.5 27 30 16 21 26 32 41 50 17 24 28 36 43 55 8 8 8 8 13 13 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3P1A LQ3P2A LQ3P3A LQ3P4A LQ3P5A LQ3P6A 1/4 (E) (E) L Panel Aperture (K) Straight Union : LQ3U (mm) Inch Size H Model Tubing O.D.
Key Position and Rotation Range Single vane type Double vane type 90 180 270 90 n o r a a ti r n n g n a o e g n o t ti r a ti o n a a 2 e g t r t o 7 e o 1 r y 0 r 9 8 y e 0 y +4 0 e 0 Key K e K +4 0 +4 0 K +4 0 Key Key 0 (45) 9 Key e Standard Optional g n a r n o ti a t o r (90) y e K (45) (45) A port B port A port A port A port B port B port B port 100 190 280 100 a r n n n r o a g
We hope you found both the iii PneuAlpha iv PneuAlpha Guidelines for the safety of the user and protection of ECC-PNAL-PCS/WIN-E This manual provides information for the use of ECC-PNAL-PCS/WIN-E. The manual has been written to be used by trained and competent personnel.
generator used. 1 40 30 From the flow-rate characteristics of the vacuum generator (Chart 1), calculate the suction flow (Q1) of the vacuum generator from the required vacuum pressure. 20 10 e 00 10 20 30 40 50 60 70 80 90 100 110 Vacuum pressure 50 kPa (qwe) = Suction flow (Q1) 31 l/min (ANR).
CVM5/CVM5K MXU 20 Standard 3.5-18 Double acting 25 MXS 3.5-29 32 Nonrotating rod 40 MXQ MXF Series CVM3/CVM3K 20 Standard MXW Single acting 3.5-34 25 (Spring return) 3.5-47 32 Nonrotating rod (Spring extend) MXP 40 MG Series CV3/CV3K 40, 50 63, 80 100 MGP 3.5-52 Standard Double acting MGQ Nonrotating rod 40, 50 63 3.5-63 MGG MGC Series CVS1/CVS1K 40, 50 63, 80 100 3.5-67 Standard MGF Double
/60 Hz 00 01 Without sub-plate Rc 1/8 (6A) Accessory 2 200 VAC, 50/60 Hz Without sub-plate (For manifold) 4 Indicator light (DC is possible only for DL.)
Weight g (oz) Model IN side, OUT side ZFC100-04 4 10 (0.35) 11.5 (0.41) ZFC100-06 6 20 (0.70) Metric size ZFC200-06 6 30 (1.05) 21.5 (0.76) ZFC200-08 8 50 (1.75) ZFC101-03 5/32" 10 (0.35) 11.5 (0.41) ZFC101-07 1/4" 20 (0.70) Inch size ZFC201-07 1/4" 30 (1.05) 21.5 (0.76) ZFC201-09 5/16" 50 (1.75) Note 1) Flow rate when initial pressure drop is 0.003MPa (0.44psi) or less.
1 10 L . 10-1 10.1 . 10-1 10.2 . 10-1 10.3 . 10-2 10.4 . 10-2 11 R .11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 12 T . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 12.4 . 12-3 12.5 . 12-4 13 V . 12-5 13.1 . 13-1 13.2 . 13-1 13.3 . 13-2 14 . 14-1 14.1 . 14-1 IDF60/70/80/90 Series IDX-OM-W093 1 1.1 () 6.2 1.1.1 3 IDF60/70/80/90 Series 1-1 IDX-OM-W093 1.2 6 1.2.1 1.2.2 50
F G H J K L M N P IDF22E R1 775 6001 IDF37E R11/2 855 6801 85 340 (698) (93) 46 25 290 623 (134) (405) 13 314 IDF55E, IDF75E Guige Guige 10 (10, 1m 1m) 4-13 17 (911)[] mm A B C D E F G H J K L M N P Q R IDF55E 800 (868) IDF75E 900 (968) 526 (250) 5195 13 500 75 7001 (455) (110) 36 50 R2 470 855 (128) IDF Series 6-3 6 2 IDX-OM-W026 6 6-4 IDF22E-20, IDF37E-20 IDF22E-30, IDF37E-30 GFCI
No.PS-OMM0002CN-F / / ZSE80(F) ISE80(H) 2 9 10 11 14 14 16 17 19 19 21 21 21 F0 23 F1 OUT1 24 F2 OUT2 27 F3 27 F4 / 28 F5 30 F7 31 F8 32 F9 34 F10 35 F98 36 F99 38 39 42 42 43 50 50 52 -1No.PS-OMM0002CN-F (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems.
Weight g (oz) Model IN side, OUT side ZFC100-04 4 10 (0.35) 11.5 (0.41) ZFC100-06 6 20 (0.70) Metric size ZFC200-06 6 30 (1.05) 21.5 (0.76) ZFC200-08 8 50 (1.75) ZFC101-03 5/32" 10 (0.35) 11.5 (0.41) ZFC101-07 1/4" 20 (0.70) Inch size ZFC201-07 1/4" 30 (1.05) 21.5 (0.76) ZFC201-09 5/16" 50 (1.75) Note 1) Flow rate when initial pressure drop is 0.003MPa (0.44psi) or less.
L/min w e L t Unit display of flow rate for air/ Red (PF2A200, 201 for air only) CH1 to 4 will illuminate when the normal condition (nor) is selected. e OUT1 CH y Unit display/Orange Illuminates the selected unit.