SMC Corporation of America
Elite Part Number Search
Search Results "CP96SDG50-25C"

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)150 mA or less250 g1/8, 1/4Heater type3-digit, 7-segment LED?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

1 digit (at 25C ?3C ambient temperature)Lights up when output is turned ON. OUT1: Green OUT2: RedIP40Operating: ?5 to 50C, Stored: ?

Viscosity: 3mPas (3cP) or less Detection style Karman vortex Flow rate measuring range 0.4 to 4l/min 1.8 to 20l/min Note 1) 4 to 40l/min Operating pressure range Note 2) 0 to 1MPa 0 to 0.6MPa Proof pressure Note 3) 1.5MPa 0.9MPa Operating fluid temperature 0 to 90C Linearity Note 4) 2.5%F.S. or less (at 25C water) Repeatability 1%F.S. or less (at 25C water) Temperature characteristics 5%F.S

, Stored: 10 to 60C (With no condensation or freezing) Operating and stored: 35 to 85% RH (With no condensation) 250VAC for 1 min, between all lead wires and enclosure 2M or more (at 50VDC) between all lead wires and enclosure 10 to 500Hz with 1.5mm amplitude or 98m/s2, whichever is smaller 980m/s2 in X, Y, Z directions 3 times each (Not energized) 3%F.S. or less of measured pressure at 25C

Checks and Inspection Table 2 Facility water system Circulating type Transient type Item Circulating fluid Filling of circulating fluid Transient fluid pH [25C] 6.5 to 8.2 6.0 to 8.0 6.8 to8.0 Electrical conductivity (mS/m) [25C] 80 or less 30 or less 40 or less Standard items Chloride ions (mg/L) 200 or less 50 or less 50 or less Sulfuric acid ions (mg/L) 200 or less 50 or less 50 or less

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)150 mA or less250 g1/8, 1/4Heater type3-digit, 7-segment LED?

3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?