SMC Corporation of America
Elite Part Number Search
Search Results "IS3000-02L2-P"

Calculation D n W P t : Pad diameter (mm) : Number of pads used : Lifting force (N) : Stable vacuum pressure (kPa) : Safety factor: Horizontal pad contact: 4 (dynamic) Vertical pad contact: 8 (dynamic) Pad W D = 3.14 x P x n x t x 1000 4 1 W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Buffer mounting (Male thread) Buffer mounting (Male thread) Mounting Male thread Female thread Female thread Vacuum entry port Female thread Common Female thread Female thread Female thread P. 13-11-91 to 92 P. 13-11-86 to 88 P. 13-11-86 to 88 P. 13-11

KQ2C Caps P Plugs Q Cartridge KR Fitting Boot . . . . . . . .6 .7 .7 .7 P .8 .8 .9 .9 o 't0 1 0 1 0 1 1 1 1 1 1 1 2 Spucial [nnlhunilions Page 14 IIU lrlylon lltliltg Page 15 Bmss Phe tittittg$ pase N i p p l e s . . . . . . . . . 1 7 Cdinlinars -. -14 Bushings Aalaolers 1 8 '18 1 q Ts6s .20 .20 Pftr^q 21 SAE 45" Flares . -..22-23 .24 General Assembly..,.. lmoortant Oo's and Dont's Chemical

| '-F:# l--;:r;;P-1 ir@:-] / : I il.rdn.tnl '\ !

HOW TO ORDER N V F 1 1 0 H s D Z O 0 1 T F T T Opo.afing Pressure -J I 0 100 psi (CrP.055) | ' H 0 r 150 psi (C\p.05) | SolenP T Ii ; o Electrical Corinsctioi G 12'Lead (Sd.) D .

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C4H (One-touch Fitting ø4mm, Straight Type), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C4H (ø4 One-touch Fitting, Straight Type), Option 1: L (Lead Wire w/Connector, 2m)

Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: None, Option 3: Operating Manual Booklet, X Options: Wetted Parts: Stainless Steel 316L

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, ISE20, "PRESSURE SWITCH, N lb

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: R 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket B, Horizontal Mounting, Option 3: -

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: -

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: None, Option 3: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: R 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: w/o Operation Manual, Calibration Certificate