-P-M5 M5 x 0.8 0.13 0.35 0.52 0.15 0.43 0.60 N.C.
PLC Valve VY511-020 Controller VYU5l-D Electrical circuit W Air circuit Air cylinder Air circuit 3 Position valve E-P HYREG P2 SOL.b R S A P SOL.a 6 Throttle valve (Variable throttle) MR Throttle valve Manual valve (Fixed throttle) MP 1.15-30 Cylinder Load Changes 3.
1.3 x 10-10 P.526 XVD2-02S 522 Smooth Vent Valve (Supply Line) XVD Series RoHS How to Order 02 XVD 2 V Fitting type Smooth vent valve V S For VCR For Swagelok Space-saving Valve / needle valve integrated construction requires only 1/4 the piping space of previous models.
MGPMGP-A MGPS1.5MPa 1.0MPa 12,16 0.12MPa 16 0.15MPa 20100 0.1MPa 0.1MPa 0.2MPa 20100 -1060 ( 1263 50500mm/s 1663 50500mm/s 50400mm/s 80,100 50400mm/s 50400mm/s 80,100 +1.5 0 1 4. 4-1. (mm) 12,16 20,25 32100 mm) 10,20,30,40,50,75,100,125,150,175,200,250 20,30,40,50,75,100,125,150,175,200,250,300,350,400 25,50,75,100,125,150,175,200,250,300,350,400 MGP M L A 4-2.
3 Single acting, spring return Rod seal Piston seal NBR CQSB12-S-PS CQSB16-S-PS CQSB20-S-PS CQSB25-S-PS 12 16 20 25 CQSB12-S-PS CQSB16-S-PS CQSB20-S-PS CQSB25-S-PS Tube gasket Seal kit includes !3. Order the seal kit, based on each bore size. Since the seal kit does not include a grease pack, order it separately.
It varies depending on operating pressure.Refer to ''Flow Characteristics" p.4.6-29 and figure of "Max. air flow" p.4.6-28. Removes odor and gas ingredients in compressed air.
Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ZSE ISE ON YES OFF P-1 P-2 GPM gal (US) PSE Real-time flow rate GPM = gal (US)/min P Window comparator mode H: Hysteresis Z I SE3 Note) Fixed SI unit (l/min, l, m3 or m3 x 10) will be set for the type without the unit switching function.
of auto switches Auto switch Nil S 3 n 2 pcs. 1 pc. 3 pcs. n pcs.
See the intersection of lateral axis 500 mm/s and 63 line, and extend the intersection to left.
CG1N20-S-PS CG1N25-S-PS CG1N32-S-PS CG1N40-S-PS 20 25 32 40 CG1N20-S-PS CG1N25-S-PS CG1N32-S-PS CG1N40-S-PS NBR Piston seal !8 Disassembly/Replacement Caution Since the seal kit does not include a grease pack, order it separately. Grease pack part no.: GR-S-010 (10 g) 1. Do not replace the bushings. The bushings are press-fit.
How to see the serial number S O 001 January 2014 S O 001 Year Symbol Remarks Month Symbol Remarks Serial no. 2014 S Repeated from A to Z in alphabetical order 1 O Repeated from O to Z in 2015 T 2 P alphabetical order, with O for January and Z for December 2016 U 3 Q Fig. 1-1 Position of the product label HRS Series 1.4Product Label 1-3 HRX-OM-S004 Chapter 1 Safety Instructions 1.5 Safety
Note 3) 200 to 240VAC is "S" specification standard. Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available.
Operating pressure: P (MPa) 3. Weight of total loads: Wo (kg) Wo = (Load weight: WA) + (Jig weight: WB) 4. Operating piston speed: v (mm/s) Calculate required output FA 9.8 x Wo FA = Take next larger bore size than D Operating pressure (MPa) 0.4 0.2 0.5 0.3 0.6 0.4 or more Check Theoretical Output FO Fo: Refer to "Theoretical Output" on page 2.
Note) In the case of body options S and L, the materials of the part nos. e and r are as follows: (Example): VN1-A3BA However all brackets of valve element VNB 1 to 4 are made of stainless steel. (No need to add options S and L.)
ester FH54 0 1 CB-65H Petroleum, Water-glycol, Emulsion to CB-65H-V Phosphoric ester FH64 0 1 AG-9H Petroleum FH34 0 1 to AG-9H-W Water-glycol, Emulsion FH64 0 1 Blanking cap (for differential pressure indication part) AG-9H-V Phosphoric ester AG-12H Petroleum FH342 AG-12H-W Water-glycol, Emulsion AG-12H-V Phosphoric ester 510 A Line Filter FH34/44/54/64 Series How to Order FH 03 3 40 0 0 0 P
Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output Max. 30 V, 80 mA Residual voltage 1 V or less 1.5 MPa Withstand pressure 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at no load) Current consumption
Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.1.0-1 and 1.0-2 for precautions on every series. Selection Warning qThe residual secondary pressure cannot be released by releasing the supply pressure. To release the residual pressure, contact SMC.
Exr 27N-4O (40pm), 2NB '||oL: O.der ol assembly (Erample) OO' NAF + NAFI + iIAL Port Atlachment modl Air entry Port sire Applicable 0 6 % N P T t o I N P T Description Location s MF +NAq +a +M! NAF +6+ NAR NAC50?
70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 P (Piping port) Model Mounting nuts (2 pcs.) are shipped together.