Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn Locking Lever

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire

Body Size: 6 (1/2 Basis), Port Size: N04 [Cylinder Side (NPT 1/2) Pilot Port (NPT 1/4)], Applicable Tube OD: 11 (Ø3/8"), Lock Nut: J (Round)

This is a legacy product, and replaced byAN40-N04 AN SILENCER. MUFFLER *LQA. AIRLINE EQUIPMENT. AN 1/2INCH STANDARD (NPT). .00000 lb. FD.

This is a legacy product, and replaced byAW40-N04-7Z-2-B AW MASS PRO. FILTER REGULATOR, MODULAR. AIRLINE EQUIPMENT. AW MASS PRO 1/2 MODULAR (NPT). 2.21103 lb. FC.

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .54013 lb

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 1.32277 lb

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 1.01569 lb

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch.  Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility.  Designed to work with fluids up to 90ºC