Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: C4 (4mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
.: 32mm), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: YZ (EN 175301-803C terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: S (Single), Soft Start-up: S (with
Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 14 (1 1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
(Normally Closed)], Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: M (with Clogging Switch, 1 Point), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa
(Normally Closed)], Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: M (with Clogging Switch, 1 Point), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa
(Normally Closed)], Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: M (with Clogging Switch, 1 Point), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -