S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa. 1.12-16
(mm) a = Internal cross section of piping [mm] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4 2.5 4.9 QC = Air consumption required for one reciprocation of Mini-Rotary Actuator [l (ANR)] 6 4 12.6 8 5 19.6 8 6 28.3 6.5 33.2 10 7.5 44.2 12 8 50.3 12 9 63.6 9.2 66.5 16 12 113 12.7 127 16 13 133 16.1 204 21.6 366 27.6 598 Air Consumption
In this case, please verify the rigidity of the equipment carefully. 40 50 63 80 100 Table 1 Air cushion 2.8 4.6 7.8 16 29 Allowable kinetic energyJ Non cushion 0.33 0.56 0.91 1.50 2.68 9 2-7. Cushion C a u t i o n Cylinder cushions are adjusted properly at the time of shipment.
The maximum number of connections of manifold valve/Input unit manifold is 16/branch x 4 branches = 64 points each for output and input.
Tightening of M3, M5, and M6 connection threads 1) M3 After tightening by hand, tighten an additional 1/4 rotation with the correct tool. 2) M5 and M6 After tightening by hand, tighten an additional 1/6 rotation with the correct tool. Overtightening can cause damage to the threads and/or air leakage due to deformation of the gasket.
Description Qty. 4 Seal 1 4 Seal 1 4 Seal 1 4 Seal 1 Parts included 11 Gasket 1 11 Gasket 1 11 Gasket 1 11 Gasket 1 12 Gasket 1 12 Gasket 1 12 Gasket 1 12 Gasket 1 in seal kit 16 Wear ring 4 16 Wear ring 4 16 Wear ring 4 16 Wear ring 4 17 Piston seal 4 17 Piston seal 4 17 Piston seal 4 17 Piston seal 4 Please refer to P19 to 21 for the product construction.
Metric size Inch size Air 1.5 MPa (1.05 MPa Note 1)) 1 MPa (0.7 MPa Note 1)) 0.1 MPa 5 to 60C (No freezing) Applicable cylinder bore size (mm) 2 3.2 4 6 8 10 12 1/2" 3/8" 5/16" 5/32" 1/4" 1/8" AS1002F AS2002F AS2052F AS3002F AS4002F 6, 10, 16, 20 Note) 20, 25, 32 20, 25, 32, 40 40, 50, 63 63, 80, 100 Note 2) Nylon, Soft nylon, Polyurethane Applicable tube material Note 1) In case of AS1002F
to 100C 16 or more circuits Features Low torque Metal seal type Rotary joint Series MQR 1 circuit, 2 circuits, 4 circuits, 8 circuits, 12 circuits How to Order MQR F 4 M5 Connection diameter Low torque Rotary joint (Metal seal type) M5 M5 x 0.8 Number of circuits 1 circuit 2 circuits 4 circuits 8 circuits 12 circuits 1 2 4 8 12 Options N/A Standard type FNote) Flange type Note: No flange
G3/4 to G1 16, 17.5 For Oil (50 mm2/S or less) Direct Operated 2 Port Solenoid Valve For Air Pilot Operated 2/3 Port Solenoid Valve for High Pressure Valve type Port size Body Seal Valve type Port size Body Seal Material Orifice size mm Material Orifice size mm Series VCS20/30/40 Series VCA20/30/40 Series VDW10/20/30 Brass Stainless steel PTFE FKM N.C. 1/8 to 3/4 2 to 10 Brass Stainless steel
: M5 x 0.8 0XY: M6 x 1.0 771
to 100C 16 or more circuits Features Low torque Metal seal type Rotary joint Series MQR 1 circuit, 2 circuits, 4 circuits, 8 circuits, 12 circuits How to Order MQR F 4 M5 Connection diameter Low torque Rotary joint (Metal seal type) M5 M5 x 0.8 Number of circuits 1 circuit 2 circuits 4 circuits 8 circuits 12 circuits 1 2 4 8 12 Options N/A Standard type FNote) Flange type Note: No flange
Individual grounding should be provided close to the product with a short cable. 138 Seal cap (for M8 connector socket): 16 pcs. Seal cap (for M12 connector socket): 1 pc. Accessory Seal cap (for M12 connector socket): 17 pcs. EX500-DX B Install the product using 2 M5 screws x 20 mm minimum with a head 9 to 11.
(mm) a = Internal cross section of piping [mm] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4 2.5 4.9 QC = Air consumption required for one reciprocation of Mini-Rotary Actuator [l (ANR)] 6 4 12.6 8 5 19.6 8 6 28.3 6.5 33.2 10 7.5 44.2 12 8 50.3 12 9 63.6 9.2 66.5 16 12 113 12.7 127 16 13 133 16.1 204 21.6 366 27.6 598 Air Consumption
Module parameters Module parameters for valves The "16 Valves" has the following module parameters.
40 40 Rectangular Square Size Sintered body particle diameter Aperture ratio Material Finishing Material 0.5 1.2 2.1 3.2 5.8 8 0.4 1.0 1.8 2.9 5.3 7.4 mm 50 x 50 100 x 100 150 x 150 200 x 200 250 x 250 300 x 300 mm 0.3 (sphere) Adsorption surface 15% or more Stainless steel Wrapping processing Aluminum casted Body Surface processing Finishing Chromated (except for adsorption surface and
Accuracy [%F.S.] 50% 50% 50% 40% 40% 40% With 1 1/4" connected With 1 1/2" connected 30% 30% 30% With 3/4" connected Elbow piping (2") Elbow piping (1 1/2") 20% 20% 20% Elbow piping (1") 10% 10% 10% 3% 3% 3% 8 7 6 5 4 3 2 1 0 0% 0% 0% 8 7 6 5 4 3 2 1 0 8 7 6 5 4 3 2 1 0 Straight section [d] Straight section [d] Straight section [d] Straight When piping with diameter smaller than the straight
Spacer Bolt Top cover Top Cover Mounting Bolt Tightening Torque Bore size Tightening torque 25, 32 0.46 to 0.60 lbfft [0.63 to 0.82 Nm] 2 CKZT -X2797 -X2798 Dimensions CKZT S-X2797 Clamp arm (Refer to page 5 for details.) 16 93 52 53 40 10 34 13 250.1 34 3 170.05 44 A 50.1 180.1 28 +0.1 0 C B Proximity switch 2 x 4 x M5 x 0.8 depth 6 G1/8 Unclamping port A D E G1/8 Clamping port Bore size
40 100 75 50 30 0.06 63 63 40 3 4 5 7 0.3 or less 0.05 100 100 63 10 12 16 22 Note) The value given for the non-rotating accuracy is applicable below the allowable rotational torque.
Flow Rate and Effective Area AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values
Flow Rate and Effective Area AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values