SMC Corporation of America
Elite Part Number Search
Search Results "CD85KF25-50-A"

: inch [mm] A B C Model 5.3 [135] 1 [25] 1.8 [46] IDFB22E, 37E 3.2 [81] 10.6 [270] 2 [50] 1.4 [36] IDFB55E, 75E Terminal block A Option symbol V B Timer type solenoid valve with auto drain (Suitable for moderate air pressure) Power cable outlet 0.7 [17 mm] (Wire diameter 0.4 [9 to 11mm]) IDFB4E to 75E Drainage is discharged by controlling a solenoid valve with a timer.

D-C7m/C80 D-C73C/C80C D-H7m/H7mW D-H7BA/H7NF Band mounting BJ2-010 (A set of band and screw) BJ2-016 (A set of band and screw) BQ2-012(S) (A set of a and b) BQ2-012(S) (A set of a and b) Set screw (Accessory) D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA Note 5) D-M9mAV Note 5) D-A9m D-A9mV Note 4) Rail mounting BQ2-012 BQ2-012S a Auto switch mounting screw b Auto switch mounting bracket Nut (Cylinder

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Hole diameter 5 9 Features 1 3 Port Direct Operated Poppet 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 How to Order Valves Electrical entry Rated voltage 100VAC 50/60 Hz 200VAC 50/60 Hz 110VAC 50/60 Hz 220VAC 50/60 Hz 24VDC 12VDC 240VAC 50/60 Hz Other DO-DIN terminal (without connector) 1 2 3 G-grommet (lead wire length: 300mm) H-grommet (lead wire length: 600mm) D-DIN type

Applicable bore A B A B A B MY-S25 MY-S32 MY-S40 ML1C25 ML1C32 ML1C40 103 117 35 50 8 5 9.5 5.5 M6 x 1 128 146 45 64 11.7 6 11 6.6 M8 x 1.25 148 170 55 80 14.8 5 14 9 M10 x 1.5 1114 A Hy-rodless Cylinder ML1C Series Construction #9 %7 #8 #7 %6 !0 CLJ2 CLM2 CLG1 CL1 w $8 @4 i u !7 t !2 $9 !3 !1 %5 @6 @5 $5 #6 MLGC %2 CNG @8 !9 MNB e CNA2 $2 q %3 %4 $1 CNS #1 #0 @9 #4 $0 !5 !

Minimum number of T nuts required for each stroke Stroke (mm) 100400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Number of T nuts (pcs.) 8 10 12 14 16 18 20 Model LJ1-T8 (Weight: 8.4g) M8 x 1.25 17.5 7.5 15 The end cover must be removed when a T nut is inserted into the T slot. 18 11.5 M6 x 20 4 positions 45 10 T slots for mounting 9.4 4.5 T-slot size End cover A A A A 110 The A dimension

Diaphragm Assembled in a clean room.

21 24 31 41 4.5 5 6 7.5 7 8 11 14 17.5 19.5 20 25 8 10 14 18 1.25 1.25 1.5 1.5 44 49.5 60 74.5 20 25, 32 40 50, 63 Semi-standard type Pneumatic: to 1 MPa (mm) Maximum thread depth P Allowable eccentricity U Maximum operating tensile and compressive force N Applicable cylinder bore size Model Nominal size Pitch Center of sphere R M A B D E F G H Weight kg 20 25 32 32, 40 40 32, 40 50 50,

Bore size Stroke range head cap screw for CW CT CL CX CD M CZ R CN mounting pivot bracket (Accessory) Without auto switch With auto switch CQ-C032 32 5 to 50 50 60 60 20 5 30 18 10 34 45 80 6.6 M6 x 12 L 75, 100 5 to 50 58.5 68.5 66.5 76.5 CQ-C040 40 68.5 22 6 32 18 10 40 52 80 6.6 M6 x 14 L 75, 100 10 to 50 CQ-C050 50 76.5 28 7 42 22 14 50 64 80 9 M8 x 16 L 75, 100 CQ2 10 to 50 74 84 CQ-C063

B A B A B A B 50 23.5 9.0 23.5 11.0 23.5 7.0 19.5 10.5 (13.0) 63 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 80 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) ( )D-A96 -15 D-P3DW D-P3DW A B Hs Ht 50 14.5 6.5 41 35 63 16.5 10 47 44 80 30.5 17 55 54 D-P3DW BQ6-032S -16 18 - 7-3. 7-3-1.D-M9D-A9 (-) -17 5~6mm D-A9(V):0.100.20Nm D-M9(V):0.050.15Nm 90 7-3-2.D-P3DW M2.5X9.5L1 2 M2.56L

size Model Grommet: G Conduit: C Conduit terminal: T M L K H F E D C B N A U S R Q R Q R Q M4 12.8 14 28 12.5 6.5 31 64 28 4.5 13.5 83 66 50 99 50 44 59 22 1/8 VCB21 M4 12.8 18 28 12.5 8.5 31 67.5 36 6 18 86 66 53 99 53 44 62 22 1/4 M5 19 20 32 15 11 36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5

In general, a mesh of about 50 to 100 is a guideline for the filter. When using ordinary tap water, scaling and sludge from substances in hard water such as calcium and magnesium can cause solenoid valves to malfunction. It is therefore necessary to install a water softener to remove such substances and a filter (strainer) immediately before the solenoid valve.

Dimensions (mm) 1in = 25.4mm MSUA7 MSUA7-S, SE Scale: 60% Top ports/MSUA7-SE C 8-M4 x 0.7 depth 8 A port B port 67 13 2-M5 x 0.8 14 B 41 50 33 37 4-M5 x 0.8 depth 7 22.5 5 +0.025 0 3H9 A Long groove depth 5 (positioning pin hole) 22.5 47h9 0 0.062 +0.052 0 26H9 36 +0.030 0 3-4H9 depth 4 ( A , B , C ) 4 3 2-5.5 through 3-R2 3-R2 4.5 19 10.5 13 48h9 0 0.062 36 7 6 22.3 10.5 44 3 11 10 58.5

-500 Basic weight1.287 kg Additional weight0.033/50 st Cylinder stroke500 st 1.287 + 0.033 x 500 50 = 1.617 kg Technical Data 1469 A

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DX, ISE40/50/60 1/4 (MISC.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DX, ISE40/50/60 1/4 (MISC.

This is a legacy product, and replaced byISE20C-X-N02L-W, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DB, ISE40/50/60 1/4 NPT VERSION, .44092 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay