4 20: M5 x 0.8 x 6 25, 32: M6 x 1 x 6 40: M8 x 1.25 x 8 Nickel plated Carbon steel Hexagon socket head cap screw !5 20, 25: M5 x 0.8 x 6 32, 40: M6 x 1 x 8 Carbon steel Hexagon socket head set screw !6 Nickel plated !7 Plate Special resin !8 Cushion seal NBR !9 Piston seal Replacement Parts Resin @0 Wear ring NBR Bore size (mm) Kit no.
A B d H Model H A SN-015A M14 x 1 19 21.9 5 ZPNA-M16 M16 x 1.5 22 25.4 6 ZPNA-M18 M18 x 1.5 27 31.2 9 ZPNA-M22 M22 x 1.5 30 34.6 8 Bolts (Hexagonal Socket Head Cap Screw) Dimensions d B (mm) A B d L 8 11 5.5 M3 x 0.5 L 8 12 7 M4 x 0.7 A 10 15 8.5 M5 x 0.8 13-11-96
(A) 2 0.7MPa (101psi) 0.15MPa (22psi) 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa (145psi) 0.05MPa (7psi) Fluid AM150 AM250 Maximum operating pressure Rated flow rate (ANR) 300l/min (10.5SCFM) 750 l/min (26.5SCFM) Note 1) Series AM separates and removes the oil mist in compressed
(A) 2 0.7MPa 0.15MPa 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa 0.05MPa Fluid AM150 AM250 Maximum operating pressure Rated flow rate l/min (ANR) 300 750 Note 1) Series AM separates and removes the oil mist in compressed air which is troublesome for ordinary filters, and removes fine
VBA200: Qb = 500 [l/min (ANR)] VBA400: Qb = 1050 [l/min (ANR)] NO VBA400 NO Max. 0.05 MPa Avoid pulsation Judgement of flow rate Qb < Q YES VBA200 YES Can not get necessary pressure. Tank capacity (l) Tc [s] = L W Obtain the tank capacity V. Select tank from table below.
bore 1/8 R 4-R 4-R 36.8 E 36.8 E R P VEX P D D AMR + + MADE IN JAPAN ITV MADE IN JAPAN SMC SMC IC VBA Model Port size A B C D E G H I VE K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000
x 0.8 15 M4 x 0.7 13 4 11 16 15 8 21 4.5 11 66 + Stroke 27.5 93.5 + Stroke 10, 16, 20, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 MM A F F S + Stroke H ZZ + Stroke (mm) P Bore size (mm) MM A NN D F G1 G2 S ZZ I H J N1 N2 NA TN TF 10 15 M12 x 1 4 M5 x 0.8 8 15 6 M4 x 0.7 65 101 18.5 28 16 11 20 16 16 15 M14 x 1 5 M5 x 0.8 10 15 6 M5 x 0.8 74 114 22 30 22 12 21 19.5 20 18
Stainless steel 9 With switch only Magnet plate Aluminum alloy 10 With switch only Switch mounting bracket 11 Scraper 12 With back-up ring Rod seal NBR 13 Piston seal 14 Tube gasket 15 Piston gasket 18 Series CHKGB Dimensions 2-Rc P F with effective thread depth G Q S Width across flats f c R D R a b g e H E C B + Stroke h + Stroke 4-K through J 8-L counter bore A + Stroke M Rod end male
Hysteresis 0 to variable 7 Withstand pressure 600 kPa Detection nozzle 1.5 4 Current flow 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple(p-p) 10% or less (with power supply polarity protection) Current consumption 25 mA or less Switch output 2 output (NPN or PNP) Max. load current 10 mA Max. applied voltage 26.4 V Residual voltage 1 V or less (at
OO PP QQ RR SS TT UU VV Model Applicable gasket ML1C25 ML1C32 ML1C40 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C11.2 17 23.5 12.5 10 53 40 34 26 C14 A B C D E F G H I J K L M N O P Q R S T U V W Y Z Model ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 M5 x 0.8 8.5 M6 x 1 9.5 11 M8 x 1.25 322 306 161 160 108 131 101 99.5 64 92 118
Auto Switches/Refer to p.5.3-2 for further information on auto switch.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration