No 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 5 V, 12 V 12 V 2-wire 3-wire (NPN equivalent) IC circuit A96V A96 5 V Grommet A93V A90V A93 A90 100 V IC circuit Relay, PLC 2-wire 12 V 24 V 100 V or less Solid state auto switches marked with are produced upon receipt of order.
DC (42 mA), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA)
DC2410% Power [W] Note8),9) Max. 86 Max. 109 Type Note10) Non-excitation-operated type specification Lock unit Holding force [N] 47 78 157 294 75 108 216 421 Power consumption [W] Note9) 5 5 Powre supply voltage [V] DC2410% Note1HorizontalUse an external guide (external guide friction coefficient: 0.1 or less).
2 VQ5250 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5351 (A) 4 (B) 2 VQ5350 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 VQ5451 VQ5450 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5551 (A) 4 (B) 2 VQ5550 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Parts list Parts list Description Material Note No. 1 2 3 Description Material Note No. 1 2 3 Body
L L+A Fig. 1 Fig. 2 L 2 1 V E = W ( ) 2 1000 Collision speed V = 1.4 Va Find the kinetic energy E (J) of the load. 1 420 E = 1 ( ) = 0.088 2 1000 V = 1.4 x 300 = 420 Correction factor (reference value) Find the allowable kinetic energy Ea (J).
Note 2) Refer to p.5.3-5 for lead wire length.
IC circuit 5 V, 12 V 3-wire (PNP) Relay, PLC 2-wire 12 V Grommet 5 V, 12 V 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) A93L 5 mZ (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-10-22 for details.
7 p. 7 Communication plug connector for IO-Link JXC-CD-T JXC-CD-S Straight type JXC-CL-S Straight type T-branch type (Accessory) To SI To ENC To SI To MOT To PWR Provided by customer Communication cable Power supply for controller 24 VDC (3 m) p. 7 Power supply plug p. 7 (Accessory) Options Conversion cable1 Controller setting kit Teaching box p. 7 p. 7 P5062-5 (0.3 m) (With 3 m cable) LEC-T1
Lead wire length* (m) Load voltage Auto switch model Electrical entry Indicator Wiring (Output) 3 (L) 5 (Z) Applicable load Special function Style 0.5 () (N) AC DC P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P C76 IC circuit P P P P P p p p P p p p p p p p P P P P P P P P 3 wire (Equiv. to NPN) 5V Yes C73 100V 12V Relay PLC C80 IC circuit No 100V
Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .
[W] at 20 Note6) 6.3 7.9 7.9 Rated voltage [V] 24VDC 0-10% Note 1) The maximum value of the horizontal workload.
Core wire colors M12 48 1 1 2 3 4 5 2 : DRAIN 6 5 Red: V+ Black: V 16 White: CAN H Blue: CAN L M12 4 3 14.9 Socket connector pin arrangement Connections Terminal no.
[1] Power supply input terminals, L1, L2: Provide specified power supply to input terminals L1 and L2. [2] Connect the motor input terminal (U, V, W) to the driver power terminal (U, V, W).
12 V Coil rated voltage DC S070 10% of rated voltage Allowable voltage fluctuation (A) 2 Class B or equivalent Coil insulation type VQ Power consumption (Current) 0.5 W (21 mA) 1 W (42 mA) 1.5 W (63 mA) 1 (P) 3 (R) DC VKF Grommet Plug-in, L plug connector, M plug connector (With light/surge voltage suppressor) Electrical entry Normally open VQZ (A) 2 Note 1) Based on JIS B 8374-1993.
12 V Coil rated voltage DC S070 10% of rated voltage Allowable voltage fluctuation (A) 2 Class B or equivalent Coil insulation type VQ Power consumption (Current) 0.5 W (21 mA) 1 W (42 mA) 1.5 W (63 mA) 1 (P) 3 (R) DC VKF Grommet Plug-in, L plug connector, M plug connector (With light/surge voltage suppressor) Electrical entry Normally open VQZ (A) 2 Note 1) Based on JIS B 8374-1993.
12 V Coil rated voltage DC S070 10% of rated voltage Allowable voltage fluctuation (A) 2 Class B or equivalent Coil insulation type VQ Power consumption (Current) 0.5 W (21 mA) 1 W (42 mA) 1.5 W (63 mA) 1 (P) 3 (R) DC VKF Grommet Plug-in, L plug connector, M plug connector (With light/surge voltage suppressor) Electrical entry Normally open VQZ (A) 2 Note 1) Based on JIS B 8374-1993.
IDX-OM-V024-F PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFB60-11-C,L,R,T,V IDFB60-23-C,L,R,T,V IDFB70-23-C,L,R,T,V IDFB80-23-C,L,R,T,V IDFB90-23-C,L,R,T,V This manual is intended to explain the installation and operation of the product.
First tentative bore size determination W D 1.6 x P W W > WV P > PV Determination of allowable load weight & pressure Inclined operation (Refer to page 75 for vertical operation.)
Analogue output 1 to 5 V Output impedance 1 K Max.28 V, 80 mA Internal voltage drop 1 V max.