Magnet: Built-in, Mounting: Front Flange, Bore Size: 2 1/2", Stroke A: 4 1/2", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 4 1/2", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 4 1/2", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 4 1/2", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 4 1/2", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 4 1/2", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 4 pcs., Dual, Tandem Option: Dual Op., Sgl. Rod
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting:
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting:
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting:
Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting:
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting:
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: