VQC4000 Thread type Note) VVQC4000-3A-1 Series Nil F T Rc G NPT/NPTF Kit type 1 2 4 Thread type VQC1000 VQC2000 VQC4000 Nil F T 1 2 3 Rc G NPT/NPTF S (EX240) kit F, P, T, S (EX250) kit L, M, S (EX500) kit Note) VQC 4000 thread port only Note) Tie-rods (2 pcs.) for additional stations included. U-side end plate assembly !8 U-side end plate assembly part no.
Repeatability 3% F .S. Sensitivity 0.5% F .S. Linearity 3% F .S. or less Lubrication Not required (Use turbine oil Class 1, ISO VG32, if lubricated.)
D B Valve size PVQ Sub-plate VEXD-5 VEXB-2-2 P (Port size: M5) VY1 VY1 Thread type Port size Symbol A B Port size M5 Symbol Nil F N T Thread type Rc G (7) VBA VBAT 1 8 AP100 NPT NPTF VYD-7 VEXB-4-1 Base gasket 2 4 Valve size VEX1-9-1 P VEX4-2AP Sub-plate Port size Thread type Port size Thread type Symbol A B Port size Symbol Nil F N T Thread type Rc G (7) Symbol A B C Port size Symbol Nil
Accelerating torque calculation (Example) (Example) Friction coefficient Ta = I x (Nm) Mass m F = mg Clamp F F I : Inertial moment Static torque calculation Movement Load Refer to features page 5. : Angular acceleration = (rad/s) Tf = F x l (Nm) g = 9.8m / s F: Pressing force (N) l l Static torque calculation 2 Load t2 Ts = F x l (Nm) Lever : Rotation angle (rad) t : Rotation time
Accelerating torque calculation (Example) (Example) Friction coefficient Ta = I x (Nm) Mass m F = mg Clamp F F I : Inertial moment Static torque calculation Movement Load Refer to features page 5. : Angular acceleration = (rad/s) Tf = F x l (Nm) g = 9.8m / s F: Pressing force (N) l l Static torque calculation 2 Load t2 Ts = F x l (Nm) Lever : Rotation angle (rad) t : Rotation time
Nomihal diameleri 3mm 41-140.F (5-60.C) Non-lube Not available Male thfead (srd.)
Nomihal diameleri 3mm 41-140.F (5-60.C) Non-lube Not available Male thfead (srd.)
F Catchers F Catchers Clamping force (when 0.5 MPa supplied) A A 30,000 Clamping force F (N) 25,000 T-type arms S-type arms 20,000 15,000 Generated position of clamping force F (mm) 10,000 Arm type A T200, T240, T270 S200, S240 107 5,000 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Distance H from clamp position (mm) 80 A Frame Clamp Cylinder WRF100 How to Order C T200 WRF100 Protective cover
A M2 = F x L M3 = F x L M1 = F x L Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Note) Deflection: Displacement of point A when force acts on point F Point A: Indicates a measurement point CYV15 (M1) CYV15 (M2) CYV15 (M3) 0.05 0.05 0.05 0.04 0.04 0.04 Deflection
In measurement mode, press the S button for 2 seconds or longer, to display [F 0]. The [F ] indicates the mode for changing each Function Setting.
Front In measurement mode, when the button is pressed for 2 seconds or longer, [F 0] is displayed. This [F ] indicates the mode for changing each functional setting. Press the button for 2 seconds or longer to return to measurement mode. 2. [P_1] or [n_1] and the set value are displayed alternately.
= F x L M3 = F x L M1 = F x L Note) Deflection: Displacement of point A when force acts on point F Point A: Indicates a measurement point CYV15 (M1) CYV15 (M2) CYV15 (M3) 0.05 0.05 0.05 0.04 0.04 0.04 Deflection (mm) Deflection (mm) Deflection (mm) 0.03 0.03 0.03 0.02 0.02 0.02 0.01 0.01 0.01 0.1 0.2 0.3 0 0.1 0.2 0.3 0 0.1 0.2 0.3 0 Moment (Nm) Moment (Nm) Moment (Nm) CYV32 (M1) CYV32 (
O e p u t ) h c n I ( . n i M e l o h . a i d d a e r h T F N U l e d o M H ) . x e H ( D L A M . t W ) f g ( 4 / 1 1 / 5 6 8 1 0 0 7 0 E R K 1 1 / 6 1 ) 6 4 . 7 1 ( 3 6 . 0 ) 6 1 ( 2 5 . 1 ) 5 . 8 3 ( 0 6 . 0 ) 8 0 . 5 1 ( 5 7 . 0 ) 9 1 ( 8 1 . 0 ) 6 . 4 ( 5 3 8 / 3 / 1 8 4 1 0 0 1 1 E R K 1 ) 4 . 5 2 ( 0 8 . 0 ) 3 . 0 2 ( 3 8 . 1 ) 2 4 ( 1 9 . 0 ) 3 2 ( 1 9 . 0 ) 3 2 ( 8 2 . 0 ) 7 ( 3
Use at high temperalure up to 300"F. . Double acting only 250 PSt (17.5 I PSI -4 -300"F (-202 -20 inch/sec No cushion available Double end. Front nose, Rear Pivot HolII TO ORDER Sbd( Sirofe Lbt n"u@ Ex.) NCUB 075-040GXBG ---EHiqh temperature Aulo-sryitch capable not available. . Low temperature down to -22"F. .
0.67 0.77 0.85 0.93 1.00 1.06 1.11 1.15 1.18 1.21 1.23 1.25 1.27 1.28 Correction factor for ambient temperature changes : ambient temperature F 80 90 100 110 115 factor 1.09 1.06 1.00 0.90 0.83 Correction factor for inlet air temperature changes : air temperature F 90 100 110 115 factor 1.15 1.00 0.86 0.78 Correction factor for dew point changes : DewPoint F 37.8 39.2 41.0 42.8 44.6 46.4
This is not a clean room series product. 4 MACM Series Dimensions W (Workpiece loadable range) 4 x D At maximum offset (A + 2 x S) S F DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
Driver Servo amplifier 24VDC (Note 4, 12) Controller (Note 7) Positioning module CN1 QD75D (Note 7) 21 DICOM CN1 (Note 2) Trouble (Note 6) 20 46 DICOM 48 ALM RA1 14 13 Zero speed detection CLEARCOM DOCOM 23 ZSP CLEAR CR 41 RA2 (Note 12) Limiting torque RDYCOM 12 25 TLC RA3 READY 11 RD PP PG NP NG 49 10 11 35 In-position 24 INP 15 16 RA4 PULSE F PULSE F 10m max. 17 PULSE R PULSE R 18 36 4
Troubleshooting . 40 7.1 Alarms List . 40 7.2 Warning List . 42 2 - LECYM Series / Driver Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.