-X465 0.1 to 1 Set pressure range (MPa) Desolution of setting and display (MPa) Power supply voltage Specifications AU 0.001 Class 10 With M5 fitting (Applicable tubing O.D. 6) Pressure switch Cleanliness Breather port 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection) 45 mA or less (but 70 mA or less at current output) AF IR1000/2000: With M5 fitting (Applicable
PB1000 PA Proper tightening torque (Nm) Connection threads M5 1/6 turn after tightening by hand PAX Rc 1/8 2 to 3 4. Do not drop or bump. Do not drop, bump or apply excessive impact (1000 m/s2) when handling. 5. Never mount in a place which will be used as a scaffold during piping work. Damage can be caused if subjected to an excessive load.
8 24 76 46 66.5 101 66.5 68 99 VCB31 30 50 86 1/2 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101 71 68 104 22 45 90 1/4, 3/8 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 VCB41 30 50 94 1/2 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 35 60 102 3/4 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 17-2-27
8 81.5 1/4, 3/8 VCL31 24 25 59 46 57 60 54.5 48.5 101 57 68 104 30 50 36.5 13.5 15 32 25 23 M5 8 86 1/2 26 26.5 64.5 48 62.5 62 60 50.5 103 62.5 70 107 22 45 41 11 17 36 22.5 23 M5 8 90 1/4, 3/8 VCL41 26 26.5 66.5 48 64.5 62 62 50.5 103 64.5 70 111.5 30 50 41 13.5 17 36 25 23 M5 8 94 1/2 26 26.5 70 48 68 62 65.5 50.5 103 68 70 119 35 60 41 17.5 17 36 30 28.2 M5 8 102 3/4 Note) For class
71 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 30 50 94 41 13.5 17 36 25 23 M5 8 VCS41 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 17-2-45 8 Series VCS How to Order Manifold How to Order Manifold Assembly VV2C S D 2 02 01 Enter the mounting valve and option part numbers under the manifold
19 20 32 15 11 36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5 36 17 11 41 90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119 70 86.5 103 86.5 48 96 26 3/4 4 Series VCB Model Selection
8 1/4, 3/8 VCL31 104 24 25 59 46 57 60 54.5 48.5 101 57 68 30 50 84 36.5 13.5 15 32 25 23 M5 8 1/2 107 26 26.5 64.5 48 62.5 62 60 50.5 103 62.5 70 22 45 89 41 11 17 36 22.5 23 M5 8 1/4, 3/8 VCL41 111.5 26 26.5 66.5 48 64.5 62 62 50.5 103 64.5 70 30 50 93.5 41 13.5 17 36 25 23 M5 8 1/2 119 26 26.5 70 48 68 62 65.5 50.5 103 68 70 35 60 101 41 17.5 17 36 30 28.2 M5 8 3/4 Note) For class H
71 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 1/4, 3/8 VCS41 30 50 94 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 3/4 4 Direct Operated 2 Port for Steam Series VCS How to Order Manifolds How to Order Manifold Assemblies (Example) D VV2C S 2 02 01 Enter the valve and option
Caution Caution When the VEX3420 air operated power valve is delivered from our factory, the M5 threaded pilot ports P1 and P2 in the cover are open and the Rc1/8 pilot port in the subplate is plugged. Before connecting pipes to P1 and P2 ports in the subplate, remove the 1/8 plug from the subplate and put M5 plugs into P1 and P2 ports in the cover.
Port size Body size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Metric size Inch size 3.2 to 12 1 to 4 M5 to 1/2 1/8" to 1/2" Refer to the Web Catalog for details.
Rz 12.5 45 Female thread size Chamfered dimension D (Recommended value) M5 5.1 to 5.4 10-32UNF 5.0 to 5.3 2. Use G external threads with G internal threads. D For Uni Thread 45 Tightening method 1.
Screw lightly the auto switch mounting screw (M5 x 0.8 x 16 L). 4. Set the whole body to the detecting position by sliding, tighten the mounting screw (M5 x 0.8 x 16 L) to secure the auto switch. (The tightening torque should be about 2 to 3 Nm.) 5. Modification of the detecting position should be made in the state of 3. Auto Switch Mounting Bracket Part No.
33.5 7 5.5 5.5 5 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 26.5 22 20 20 51 42.5 34.5 30 181 159 146 146 M26 x 1.5 M26 x 1.5 M20 x 1.5 247 217 204 200 1/8 40 32 25 20 24 22 22 18 26-0.033 0 1/4 1/8 1/8 16 13 13 26-0.033 0 32-0.039 0 8 10 M32 x 2 1011Axial foot (L): RECL G H G F Width across flats B2 A K 2 x P (Rc, NPT, G) NA AL F Width across flats B1 H1 2 x NN Standard port Relief port M5
female thread M5 x 0.8 OUT IN OUT Thread type Nil N Rc NPT OUT IN OUT Note 1) Use caution not to tighten excessively when mountinga pressure gauge, otherwise it may result in a breakdown.
Body fixed A Maintenance Warning L Model Screw size Max. tightening torque [Nm] A [mm] L [mm] LEFl16 M3 0.6 3.5 20 LEFl25 M4 1.5 4.5 24 LEFl32 M5 3.0 5.5 30 LEFl40 M6 5.2 6.6 31 Maintenance frequency Perform maintenance according to the table below.
Applicable Model Model AR10 Port size M5 AR 10 X406 M5 A 0.4 MPa setting w q Option/Semi-standard: Select one each for a to f. Option/Semi-standard symbol: When more than one specification is required, indicate in alphabetic order.
Port size Body size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Metric size Inch size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Flow rate 0 5 10 Number of needle rotations Refer to the Web Catalog for details.
._3d_items_collection = {}; } SMC AN101-01 silencer, AN SILENCER $2.80 + Add to Quote Add To Cart Add to Cart SMC AN120-M5 muffler, m5 (nom 10/32), AN SILENCER