M5 x 10 DIN913-45H VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 2 8 VT G 1/4 DIN/ISO228/1 M5 Drive flange face VP VG 19.5 5.5 Solenoid valve flange face VP O-ring 16 x 2 1.5 3 S070 VQ VKF The solenoid valve can be attached with 2 mounting bolts.

M5 x 10 DIN913-45H VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 2 8 VZS G 1/4 DIN/ISO228/1 M5 Drive flange face VFS VS4 19.5 5.5 Solenoid valve flange face VQ7 O-ring 16 x 2 1.5 3 EVS VFN The solenoid valve can be attached with 2 mounting bolts.

A 24 M5 thread, depth 8 With or without insert depending on base material. 32 A' Coding stud M5 x 10 DIN913-45H 12 2 8 M5 Drive flange face G1/4 DIN/ISO228/1 19.5 5.5 Solenoid valve flange face O-ring 16 x 2 1.5 IP 3 IW 1301 AW The solenoid valve can be attached with 2 mounting bolts.

A 24 VK M5 thread 8 deep, with or without insert depending on base material. VZ 32 VF A' VFR Coding stud. M5 x 10 DIN913-45H VP4 12 2 8 VZS G 1/4 DIN/ISO228/1 M5 Drive flange face VFS VS4 19.5 5.5 Solenoid valve flange face O-ring 16 x 2 VQ7 1.5 3 EVS VFN The solenoid valve can be attached with 2 mounting bolts.

Kit components 40 MGF 40-PS Items 19 through 23 from the table above. 63 MGF 63-PS 100 MGF100-PS 4 Series MGF Dimensions 40 MGF40 Scale: 50% 4-M8 x 1.25 through 100 120 90 9.5 36.5 + Stroke 8 46 + Stroke 7.5 18.5 2-Rc 1/8 port for extending cylinder Breathing hole for guide (with element) When the cylinder is extended 38 Port for retracting cylinder M5: T-slot for hexagon bolt 4-M8 x 1.25

F G H [Tightening torque] No.LZ-OM00401 B (1/3) Electric Cylinder LZC series L[]ZC[]3[] 1.5 8 M4 x 0.7 x 6 deep [0.75Nm ] L[]ZC[]5[] 3 13 M5 x 0.8 x 8 deep [1.5Nm ] L[]ZC[]3[] M4 screw 0.75Nm M4 screw 0.75Nm L[]ZC[]3[] 4.5 8 2 7.5 11.5 12 L[]ZC[]5[] 6.5 13 3.2 10.7 16.7 15 L[]ZC[]5[] M5 screw 1.5Nm M6 screw 2.6Nm Model no.

Applicable cylinder bore size (mm) Model Metric size Inch size 1 8" 3.2 4 6 8 10 12 5 32 " 3 16 " 1 4" 5 16 " 3 8" 1 2" AS1001F 6,10, 16, 20 AS2001F 20, 25, 32 Application to inch size tubing Metric size (Release bushing: White color) 3.2, 4, 6, 8, 10, 12 Inch size (Release bushing: Orange color) 1/8", 5/32", 3/16", 1/4", 5/16", 3/8", 1/2" AS2051F 20, 25, 32, 40 AS3001F 40, 50, 63 AS4001F

32 603 543 482 422 362 302 241 181 121 603 IN Note) D-P5DWL can only be mounted on bore sizes 40 through 100. 1257 1131 1006 880 754 629 503 377 251 1257 OUT 16 40 1056 950 845 739 634 528 422 317 211 1056 IN Auto Switch Mounting Bracket Part No. for D-P5DW 1963 1767 1570 1374 1178 982 785 589 393 1963 OUT 20 50 1649 1484 1319 1154 990 825 660 495 330 1649 IN Bore size (mm) Mounting bracket

Left end adjustment limit Right end adjustment limit Dimensions Dimensions 30 3000 Applicable One-touch fittings A 25.5 KQ2H/L/T/S/Y06-M5 KQ2H/L07-M5 Other Series KQ2/KS Series KJ 16 16 13 16 AIRCHECKER PS1000-R06L + 13 MADE IN JAPAN G Pressure setting trimmer LED indicator 10 A 30 Revision history Addition of PS1200 (For vacuum) QS Edition B 6 reducer 1/4" reducer SMC Corporation of America

() -4No.PS-OML0002CN-G () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL (100 10 ) JIS B 8392-1 11.1.21.6.2:2003 () -5No.PS-OML0002CN-G * / / ,FG (35N ) () () * () 6 33 () () 10 m DC(-)() () * -6No.PS-OML0002CN-G ( ) () CE 050(5), * ON , 1015 10 /1 2146 LCD * -7No.PS-OML0002CN-G 01 N ISE30A 3 ISE30A -0.11 MPa Y ZSE30A 0-101 kPa ZSE30AF -100100 kPa K T 2 01 R1/8(M5

40 100 50 ZX 30 30 20 20 50 25 ZR 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.1 0.2 0.3 0.4 0.5 0.6 ZM Supply pressure (MPa) Supply pressure (MPa) ZMA Flow Characteristics Flow Characteristics Supply pressure: 0.4 MPa Supply pressure: 0.4 MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 ZH 70 70 60 60 ZU 50 50 40 40 30 30 ZL 20 20 10 10 ZY 0 0 10 20 30 40 50 60 70 80 90 100

16 1060 954 848 IN 1060 424 530 636 742 212 318 Note) Theoretical output (N) = Pressure (MPa) x Piston area (mm2) 9-4-3

P P P 5 to 40 Features 1 Maximum Flow Rate 3000, 6000, 12000l/min types have been newly released!

From the graph it is approx. 40%. 2Next, convert it to discharge rate of clean water. 40% of the discharge of clean water corresponds to 200mL/min. of required specification.

Model Cushion Bore size (mm) 6 10 16 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber Air 10-/21-CDU6 10-/21-CDU10 10-/21-CDU16 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 10-/21-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 6 10 16 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 5, 10, 15, 20, 25, 30

Old Model 40 126 New Model New Model Just one panel opening is required for stackable displays, which can be mounted either horizontally or vertically. ZSE30 ISE30 This function allows uniformity in the numbers displayed.

DISASSEMBLY DRAWING 1) AFM20-A 2) AFM30, 40-A Body Body Tension bolt Tension bolt Element assembly Element assembly Bowl packing Bowl packing Bowl assembly Bowl assembly 23 12.

Because the piston cycle vibration is transferred, use the following mounting bolts (VBA1: M5; VBA2, 4: M10) and tighten them with the specified torque (VBA1: 3 Nm; VBA2, 4: 24 Nm). If the transmission of vibration is not preferred, insert an isolating rubber material before installation. Mount the pressure gauge with a torque of 7 to 9 Nm. 2.