Qi '5 0 ~ 5l :r 0. 31<.-t-~-+---="I--;;::'--t-t_1 Q. 0.15 f-t.,---+t--t-+---1--+-t--t-l 8Tightening torque of mounting screw (M3) for gauge is 3-Skgf . cm.
(About 10 to 15 minutes) M3 This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenace of such equipment. Only those persons are allowed to perform assembly, operation and maintenance.
Applicable pressure sensor PSE531 PSE541 PSE561 PSE530 PSE560 PSE564 PSE550 PSE532 101 to 101 10 to 101 10 to 100 0.1 to 1 50 to 500 0.2 to 2.00 Set (differential) pressure range 5%R.D.
PSE531 PSE541 PSE561 Applicable pressure sensor PSE530 PSE560 PSE564 PSE550 PSE532 101 to 101 10 to 101 10 to 100 0.1 to 1 50 to 500 0.2 to 2.00 Set (differential) 5%R.D.
9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018-10-MT 0.8 80 0.7 70 Circulating fluid pressure [MPa] 0.6 60 0.5 Pump head [m] Available area 50 0.4 Outlet60Hz 40 0.3 30 Outlet50Hz 0.2 20 Return port 0.1 10 Available area 0.0 0 0 5 10 15 20 25 5 Circulating fluid flow [L/min] Fig 9.6-3 Pump capacity(HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT) 9.6.4 HRS012--20-T, HRS018
HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
Actuation: 1 (Single Type), Body: 3 (Body Ported, Manifold), Option: W (For Large Flow, Vacuum), Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector, w/Lead Wire; with Light/Surge Voltage Suppressor), Port Size: M5
Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot
Right angle, 5 m With mounting screw 2 pcs. 16-8-17 18 Series ISA2 DIN Rail ISA-5L Applicable models L 4.5 8 1.25 7.5 Part no.
Measure the amount of clean water which is dispensed 10 times continuously and convert it to one shot of dispensed volume. Repeat this measurement 10 times, and indicate the difference (%) between the average value of 10 sets of data (converted value of one shot) and the maximum and minimum values.
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
IP8000 IP8100 Type Item Lever type lever feedback Rotary type cam feedback Single action Double action Single action Double action Input current Input resistance Supply air pressure Standard stroke Sensitivity Linearity Hysteresis Repeatability Coefficient of temperature 4 to 20mADC Note 1) 23515 (4 to 20mADC) 0.14 to 0.7MPa 10 to 85mm (Deflection angle 10 to 30) 60 to 100 Note 2) Within
No.IP80-OM00019-B / / * 3-4 5 1. 5 2. 6-7 2-1 IP8000 6 2-2 IP8100 7 3. 8-9 3-1 IP8000 8 3-2 IP8100 9 4. 10-12 5. 13 5-1 13 5-2 13 6. 14 7. 15-17 7-1 16 7-2 17 7-3 17 8. 18 9. 18-20 10. 20-22 11. 23-25 11-1 23 11-2 IP8100 23 11-3 IP8000 24 11-4 24 11-5 25 12. 26 13. 27-33 2 A (ISO/IEC)(JIS)*1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic
Type: Manual Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 16, Seal Type: Bellows Seal, Sonic Conductance: 5L/S, Seal Material: FKM 1349-80, Amount of leakage(Pa·m3/s): Internal: 1.3 × 10-10, External
Type: Manual Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 16, Seal Type: Bellows Seal, Sonic Conductance: 5L/S, Seal Material: FKM 1349-80, Amount of leakage(Pa·m3/s): Internal: 1.3 × 10-10, External
), Number Of Switches: No switch, Seal Material: FKM 1349-80, Amount of leakage(Pa·m3/s): Internal: 1.3 × 10-10, External: 1.3 × 10-11, Body Surface Treatment: External: hard anodized aluminum, Internal: base material, Seal Change Location: None, Length of Lead Wire for Switch(m): -, Heater Yes/No: None
Series: 10 (10 Solenoid Valve Type), Thread Type: N (NPT), Voltage/ Electrical Entry: 5L (24 VDC, L plug connector w/ 300mm lead wire)
Series: 10 (10 Solenoid Valve Type), Thread Type: Rc, Voltage/ Electrical Entry: 5L (24 VDC, L plug connector w/ 300mm lead wire)
Series: 10 (10 Solenoid Valve Type), Thread Type: F (G), Voltage/ Electrical Entry: 5L (24 VDC, L plug connector w/ 300mm lead wire)
Series: 10 (10 Solenoid Valve Type), Thread Type: Rc, Voltage/ Electrical Entry: 5L (24 VDC, L plug connector w/ 300mm lead wire), Electrical Entry Direction: B (180°)