SMC Corporation of America
Elite Part Number Search
Search Results "25A-CY3B25-100"

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-PF3W7 is a digital flow sensor that constantly monitors water or coolant flow.  The upgraded 2-screen, 3-color numerical display rotates in both CW and CCW directions, offering improved visibility in a range of orientations. 

Additional options include a mounting bracket, flow adjustment valve and M8 lead wire.  25A-PF3W5 is grease-free, IP65 rated, CE and RoHS compliant.

CAT.ES11-80 A 5-Port Solenoid Valve Series VQC NEW CONCEPT Connector Type Manifold Series VQC1000/2000/4000 Outstanding response times and long life Conforming to IP67 for protection from dust and moisture (Metal seal: Single type with light and surge suppressor) VQC1100: 10ms 2ms; 200 million cycles VQC2100: 20ms 2ms; 200 million cycles VQC4100: 17ms 3ms; 100 million cycles (Based on IEC529

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.   25A-PFM7 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide. The 3-digit LED display can be red or green, changing when a set point is reached.  Either instantaneous or accumulated flow can be shown. 

Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Fluid: air; Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC; Base mounted or Body ported; Ambient & fluid temperature: 50°C; Series 25A-SY5000/7000 is compatible with secondary battery applications

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

Series 25A-AV-A soft start-up valves allow the user to set the initial rate of system pressurization to minimize system shock. The 25A specifies that this product is compatible with secondary battery. When deactivated, the valve quickly exhausts the system for safe servicing of equipment.

Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.   25A-PFM7 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide. The 3-digit LED display can be red or green, changing when a set point is reached.  Either instantaneous or accumulated flow can be shown. 

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

kPa to 0.6 100 kPa to 0.6 100 kPa to 0 100 kPa to 0 100 kPa to 0 100 kPa to 0 100 kPa to 0.6 100 kPa to 0.6 N.C.

2 Driver type* Compatible driver Power supply voltage [V] Nil Without driver A1 LECSA1 100 to 120 A2 LECSA2 200 to 230 B1 LECSB1 100 to 120 B2 LECSB2 200 to 230 C1 LECSC1 100 to 120 C2 LECSC2 200 to 230 S1 LECSS1 100 to 120 S2 LECSS2 200 to 230 LEY25: 200 mm or less LEY32: 100 mm or less *3 Rod flange is not available for the LEY25 with stroke 30 mm and motor option With lock. *4 Head

2000 100 2000 100 2000 LEHS LEHS10 LEHS20 LEHS32 LEHS40 2] 2] 2] 2] [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s 0 5 100 5 100 5 100 5 100 1 7 150 10 150 10 150 10 150 2 10 200 15 200 15 200 15 200 3 12 300 20 300 20 300 20 300 4 15 400 25 400 25 400 25 400 5 20 500 30 500 30 500 30 500 6 25 600 35 600 35 600 35 600 7 30 700 40 700 40 700 40 700 8 35 800 45 800 45 800 50 800 9 40

to 100 N Without pressure switch for vacuum/pressure sensor 100 to 100 i Option4 (For details on the Function/Application, refer to page 121.)

ldbF k pcd by 6 Edd h with integral with integral vacuumgauge digitalswitch 56 IllL $en ) Schematic Symbol NZLr12-EE NZLl12 NZLl12-Efl s1.2mm 100!

ldbF k pcd by 6 Edd h with integral with integral vacuumgauge digitalswitch 56 IllL $enie Schematic Symbol NZLr12-EE NZLl12 NZLl12-Efl s1.2mm 100!