Applicable flange size Applicable tubing size (mm) 2 4 4 5 5 5 6 6 6 Size Symbol Applicable flange size Applicable tubing size (inch) 2 4 4 5 5 5 6 6 6 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 10K-20A 10K-20A 10K-25A 10K-15A 10K-20A 10K-25A 10K-20A 10K-25A 10K-40A 6 x 4 1/4" x 5/32" 2 2 3 1 2 3 2 3 4 B B C A B C B C D LVW 12 x 10 1/2" x 3/8" LQ1 19 x 16 3/4"
Y-strainer (Accessory) Y-strainer (40 mesh) 25A Barrel nipple (25A) (Accessory) 79 HRS090 Series Standard Type Operation Display Panel List of Function The basic operation of this unit is controlled through the operation display panel on the front of the product.
/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt fixing brackets 2 pcs. (including 4 M10 bolts) Note 10) Weight (dry state) kg Approx. 130 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less. Note 2) Use fluid in condition below as the circulating fluid.
1 pc. (4) Barrel nipple 25A 1 pc.
Electrical option Nil None S With surge voltage suppressor L With indicator light Z With surge voltage suppressor/indicator light Body size 4 15A 5 20A 6 25A 7 32A 8 40A 9 50A Refer to Table 2 below for applicability.
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.
Operate in a range such that the cylinder pressure is less than two times the supply pressure. 00 51 Applicable solenoid valve 1 2 VQ54 VQ5 VVQ5000-25A-1 (plug-in type) VVQ5000-25A-5 (plug lead type) Can hold an intermediate cylinder position for an extended time When combined with a double check spacer with built-in double check valve, it is unaffected by air leakage between the spool valves
Magnet: D (Built-in Magnet), Mounting: U (Rod Trunnion), Type: N (Rubber Bumper), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 25mm, Rod End Thread: Rod End Male Thread
Magnet: D (Built-in Magnet), Mounting: D (Clevis), Type: A (Air Cushion), Bore: 32mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 25mm, Rod End Thread: Rod End Male Thread
Magnet: D (Built-in Magnet), Series: A2, Mounting: C (Single Clevis), Bore Size: 50mm, Stroke: 25mm
Magnet: D (Built-in Magnet), Series: A2, Mounting: B (Basic), Bore Size: 63mm, Stroke: 25mm
Magnet: D (Built-in Magnet), Series: A2, Mounting: G (Head Flange), Bore Size: 100mm, Stroke: 25mm
Bore Size: 10mm, Stroke: 25mm, Auto Switch: -, Lead Wire or Prewired Connector: -
Magnet: D (Built-in), Mounting: BZ (Boss-cut/Basic), Bore: 32mm, Port Thread: Rc, Stroke: 25mm, Cushion: Rubber Bumper, Rod End Thread: Rod End Thread
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper-zinc Material, Operating Pressure(MPa): 0.1 to 1, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper-zinc Material, Operating Pressure(MPa): 0.1 to 1, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper-zinc Material, Operating Pressure(MPa): 0.1 to 1, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Non-use of Copper-zinc Material, Operating Pressure(MPa): 0.1 to 1, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number