Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 100 (10000mm, Semi-standard), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8)
Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 100 (10000mm, Semi-standard), Manual Override: Non-locking Push Type, A,B Port: N9 (ø5/16" One-touch Fitting, Inch)
Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 100 (10000mm, Semi-standard), Manual Override: Non-locking Push Type, A,B Port: C6 (ø6 One-touch Fitting, Metric)
Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 100 (10000mm, Semi-standard), Manual Override: Non-locking Push Type, A,B Port: N7 (ø1/4" One-touch Fitting, Inch)
Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 10000mm, Semi-standard, Manual Override: Non-locking Push Type, A,B Port: 1/8, Thread Type: NPTF, Bracket: -
Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 10000mm, Semi-standard, Manual Override: Non-locking Push Type, A,B Port: 1/8, Thread Type: -, Bracket: -
Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 10000mm, Semi-standard, Manual Override: Non-locking Push Type, A,B Port: ø5/16" One-touch Fitting, Inch, Thread Type: -, Bracket: -
Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 10000mm, Semi-standard, Manual Override: Non-locking Push Type, A,B Port: ø6 One-touch Fitting, Metric, Thread Type: -, Bracket: -
Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 10000mm, Semi-standard, Manual Override: Non-locking Push Type, A,B Port: ø1/4" One-touch Fitting, Inch, Thread Type: -, Bracket: -
Allowable Driving Force Table (Fn) (n=1,2,3) F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 1466 for the maximum load weight when loaded directly on the body and connection bracket.) F3 = (W + WB) x 9.8 x ( + 1) Vertical Refer to the allowable driving force table for the (Fn) of data K A .
(mm) C2 F2 D1 G C3 A1 A2 B1 B2 B3 C1 D2 E1 E2 F1 R Model (size) CVRB1BW 50 CVRB1BW 63 CVRB1BW 80 CVRB1BW100 120 (136.5) 104 (120.5) 12 25 60 (61) 78 67 18 36 2.8 82.5 24 11.5 30 52 (53) 1/8 102 (136.5) 104 (120.5) 16 27.5 60 (61) 98 82 18 36 2.8 82.5 24 11.5 30 52 (53) 1/8 140 (155) 124 (139) 17 36 70 (71) 110 95 22 48 4 100 29 14 38 62 (63) 1/8 140 (155) 124 (139) 23.5 42.5 70 (71) 140 125
No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
Actuation: 2 (2-Position Double), Electrical Entry: TT (Terminal Type), Lead Wire Length: 100 (10000mm, Semi-standard), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: N (NPT)
Actuation: 2-Position Double, Electrical Entry: Terminal Type, Lead Wire Length: 10000mm, Semi-standard, Manual Override: Non-locking Push Type, A,B Port: 1/8, Thread Type: NPT, Bracket: -
Actuation: A (4-Position Dual 3 Port Valves, N.C./N.C.), Electrical Entry: TT (Terminal Type), Lead Wire Length: 100 (10000mm, Semi-standard), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: N (NPT)
4.6 9.5 14 56 38 2.5 depth 8.5 2.6 Approx. 70g LFE38 62 53 4.6 3.5 20 68 43 2.5 depth 8.5 2.6 Approx. 70g -71No.LV50***-OMQ0002-G Dimension of the cable with M12 connector lead wire (LFE-1-A3) 4 Black Blue 3 White 2 1 Brown -72No.LV50***-OMQ0002-G Revision A : Contents revised in several places.
Save the displayed waveform screen (print screen). -53- 6.10 Display All Monitor List The method how to obtain the electric actuator condition is described with the display all function of the setup software. Click Monitor Display All of the setup software to display Display All window. The condition of each item is displayed.
When monitor command "Read alarm history" is sent to the controller with controller ID: 1 Transmission data to be used in the checksum calculation "0", "1", "0", "3", "0", "6", "0", "0", "0", "0", "0", "4" (i) 01h + 03h + 06h + 00h + 00h + 04h = 0Eh (ii) FFh 0Eh = F1h (iii) F1h + 01h = F2h Checksum = "F2" (= 46h, 32h) 8.2 CRC Check Sum Calculation Procedure (1) How to calculate the CRC
F2 P3 wSub-plate Thread type Port size Thread type Rc G Note) Symbol Port size 1/4 3/8 Nil F N T Symbol 1 2 NPT NPTF !1Gasket DXT172-7 !
0 Functions in accordance with on-screen display or instructions. 6 F2 button ( ) o Functions in accordance with on-screen display or instructions. 7 F1 button ( ) On the selection screen, goes back to the previous screen.