L-bracket 53 Quick Exhaust Valve with One-touch Fittings 90-AQ240F/340F Series How to Order IN, OUT port applicable tubing O.D. 04 4 Exhaust port Body size 04 Applicable tubing O.D. 4 2 M5 04 90 04 AQ 2 4 F 0 3 4 F 0 06 AQ 06 90 Exhaust port Series compatible with secondary batteries 06 Applicable tubing O.D. 6 90 Material restriction IN, OUT port applicable tubing O.D.
How to Order Manifold VV5Q41 06 N11 SA K VQC Cylinder port SQ N7 N9 N11 1/4" 5/16" 3/8" VQ0 VQ4 VQ5 How to Order Manifold VQ4100 R 5 03 International Thread Standards Other than Rc VQZ Rc specifications are standard for all ports, however, NPT, NPTF and G are available for international markets. Add the appropriate symbol following the port size in the standard part number.
) 63 (37) 81 (55) 84 (58) 0.36 0.12 0.46 0.35 0.12 0.46 2 position 5 port Base mounted 0.33 0.39 0.12 0.10 0.47 0.59 [0.40] 0.46 0.31 0.12 0.47 0.36 0.58 [0.32] M5 x 0.8 M5 x 0.8 (with sub-plate) 0.43 [0.33] 0.32 0.16 [0.11] 0.11 82 (56) 92 (66) 3 position 0.42 [0.33] 0.16 [0.080] 36 53 41 63 37 55 2 position 5 port Body ported 0.9 M3 x 0.5 M3 x 0.5 3 position 56 66 58 36 53 41 63 37 55
35.5 59.6 [66.6] Approx. 300 (Lead wire length) 62.8 [65] 53 [55.2] 61.9 54.5 48 Refer to the page 68 for dimensions with connector cable.
How to Order Valve T 5M N7 VQZ2120 SY Example/Valve C6 5M VQZ2120R SYJ External pilot specification Thread (Cylinder ports and P, R ports) SX VK Rc(PT) External pilot port N NPT VZ M3 x 0.5 (VQZ2000) M5 x 0.8 (VQZ3000) T NPTF F G(PF) VF Note) R port of VQZ2000 is only G(PF) 1/16 VFR Cylinder ports VP7 Symbol M5 02 N1 N3 N7 N9 N11 Applicable tube O.D.
C6: 6 (SMC) N7: 1/4" (SMC) One-touch fitting [PE: Pilot EXH port] Applicable tube O.D. C6: 6 (SMC) N7: 1/4" (SMC) Applicable tube O.D.
VVQ1000-50A-N7 Applicable tubing 5/16" VVQ1000-51A-N9 Note) A-side energization: A light (Orange) illuminates.
-L) 68 2.8 depth 6.2 PF2M711/721-N7(-L) 64.6 2.8 depth 6.2 -99No.PF-OMW0007-E PF2M#L-C4/C6/C8/N7(-L) (mm) Model A C P PF2M701/702/705/710L-C4(-L) 84.4 7.6 2.8 depth 8.4 PF2M701/702/705/710/725/750L-C6(-L) 84.4 8 2.8 depth 8.4 PF2M725/750L-N7(-L) 84.4 11.8 2.8 depth 8.4 PF2M711/721L-C8(-L) 88 12 2.8 depth 6.2 PF2M711/721L-N7(-L) 88 10.3 2.8 depth 6.2 -100No.PF-OMW0007-E PF2M7#-#1/2(-L) (mm
C4 4(5/32) 10.1 8.1 C6 6 10.3 8.3 C6 6 10.3 8.3 C8 8(5/16) 12 10 C8 8(5/16) 12 10 N7 1/4 10.3 8.3 N7 1/4 10.3 8.3 PFM7-01/02--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3
> Built-in silencer C C3 (3.2) C4 (4) C6 (6) M5 (M5 thread) kit C6 (6) N1 (1/8") N3 (5/32") N7 (1/4") N7 (1/4") P. 2-4-50 P. 2-4-54
PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 PFM7-01/02--X693 PFM7S-01/02--X693 -73No.PF-OMJ0006-J PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 PFM7-01/02--X694 PFM7S-01/02--X694 -74No.PF-OMJ0006-J For a mixture of Argon (Ar) and carbon dioxide (CO2) The mixture ratio can be selected from Ar : CO2 = 92 : 8, 90 : 10, 80 : 20, 70 : 30 or 60 : 40.
Thread type Nil F N T Rc G NPT NPTF Rated voltage DC AC (50/60 Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] A, B port size 01 C6 C8 N7 N9 1/8 One-touch fitting for 6 One-touch fitting for 8 Note) Do not remove the factory installed bracket from models with the bracket option.
Name plate [-N7] VVQ1000-N7-Station (1 to Max. stations) When ordering assemblies incorporated with a manifold, suffix -N to the manifold no. It is a transparent resin plate for placing a label that indicates solenoid valve function, etc. Insert it into the groove on the side of the end plate and bend it as shown in the figure.
Specification SV2000 SV1000 SV4000 SV3000 Applicable series Manifold type Tie-rod base manifold 1(P: SUP)/3, 5(E: EXH) type Common SUP, EXH Valve stations (maximum) 20 stations Max. number of solenoids 32 points Port size 1(P)/3, 5(E) port C10, N11 C8, N9 C12, N11, 03 C12, N11 C4, C6, C8 N3, N7, N9 C3, C4, C6 N1, N3, N7 C8, C10, C12 N9, N11, 02, 03 C6, C8, C10 N7, N9, N11 4(A)/2(B) port Flow
How to Order Manifold VV5Q41 06 N11 SA K VQC Cylinder port SQ N7 N9 N11 1/4" 5/16" 3/8" VQ0 VQ4 VQ5 How to Order Manifold Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQ4100 R 5 03 International Thread Standards Other than Rc VQZ Rc specifications are standard
Note 2) Symbols for inch sizes are as follows:
handling Palletizing Automobile Case packer 254 Vacuum Pad with Ejector ZHP Series 63, 80 RoHS ZK2 How to Order ZQ ZHP 80 BM N B 00 Without ejector ZR ZB ZHP 80 BM N B 10 C6 S With ejector ZA Pad diameter Exhaust release ZX 63 63 80 80 S Silencer exhaust ZM Supply (P) port Pad form Symbol Type Port size C4 Metric 4 One-touch fitting C6 6 One-touch fitting N3 Inch 5/32" One-touch fitting N7
Actuation: 3 (3-Position Closed Center), Pilot Type: Internal Pilot, Electrical Entry: TT (Terminal Type), Lead Wire Length: 30 (3000mm)
Actuation: A (4-Position Dual 3 Port Valves, N.C./N.C.), Pilot Type: Internal Pilot, Electrical Entry: TT (Terminal Type), Lead Wire Length: 30 (3000mm)
Actuation: 4 (3-Position Exhaust Center), Pilot Type: Internal Pilot, Electrical Entry: TT (Terminal Type), Lead Wire Length: 30 (3000mm)