This is a legacy product, and replaced byAMG250C-02C
This is a legacy product, and replaced byaw20-02c-c-b, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DA, AW MASS PRO 1/4 MODULAR (PT), 0.66138 lb
This is a legacy product, and replaced byAW20-02C-6C-B, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DA, AW MASS PRO 1/4 MODULAR (PT), 0.88184 lb
This is a legacy product, and replaced byAW20-02C-B, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DA, AW MASS PRO 1/4 MODULAR (PT), 0.70362 lb
This is a legacy product, and replaced byAW20-02C-2-B, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DA, AW MASS PRO 1/4 MODULAR (PT), 0.93767 lb
Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: F (G), Port Size: 02 (1/4)
Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: F (G), Port Size: 01 (1/8)
Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: N (NPT), Port Size: 02 (1/4)
Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: N (NPT), Port Size: 01 (1/8)
Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: Rc, Port Size: 01 (1/8)
Model: Y210 [Applicable Models: AC20-(A/B), AC20B-(A/B), AC20C-(A/B)], Thread: Rc, Port Size: 02 (1/4)
Modular Type Regulator AR Series AC-A Regulator AR Series AF-A Model Port size Options AF-A AR10-A M5 x 0.8 AR-A AR-A AL-A AR20-A 1/8, 1/4 AW-A Bracket AC-B AF-A AR25-A AF-A 1/4, 3/8 Round type pressure gauge AR -A -B AR30-A AL-A Set nut (for panel mount)* AW -A -B AR40-A 1/4, 3/8, 1/2 AW AG AR40-06-A 3/4 * For AR20-A to AR40-06-A, panel fitting dimensions are different from those of the
Description Material Model Color Zinc die-cast AR10-A 1 Body White Aluminum die-cast AR20(K)-B to AR60(K)-B AR20K-B to AR60K-B (Regulator with Backflow Function) AR10-A Polyacetal White AR20(K)-B to AR40(K)-B 2 Bonnet A-A Aluminum die-cast AR50(K)-B/ AR60(K)-B y A Replacement Parts [AR10-A] 2 OUT 1 I N No. Description Material Part no.
Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air
HRX-OM-Q026-V Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH Series HRSH100-A-20HRSH100-A-40HRSH100-A-20-S HRSH150-A-20HRSH150-A-40HRSH150-A-20-S HRSH200-A-20HRSH200-A-40HRSH200-A-20-S HRSH250-A-20HRSH250-A-40HRSH250-A-20-S HRSH300-A-20HRSH300-A-40HRSH100-W-20HRSH100-W-40HRSH100-W-20-S HRSH150-W-20HRSH150-W-40HRSH150-W-20-S HRSH200-W-20HRSH200-W-40HRSH200
Height 1710 x Width 1185 x Depth 955 HRSH150-Al-A 268 HRSH200-Al-A HRSH250-Al-A HRSH300-Al-A 344 Height 2020 x Width 1230 x Depth 1040 HRSH100-Wl-A 197 Height 1610 x Width 925 x Depth 955 HRSH150-Wl-A 227 HRSH200-Wl-A HRSH250-Wl-A Mounting/Installation Warning 2.
x Width 925 x Depth 955] HRS150-W -20-A 459 [208] HRS150-A-20
231 Height 1710 x Width 1185 x Depth 955 HRS150-Al-l-A 237 HRS100-Wl-l-A 205 Height 1610 x Width 925 x Depth 955 HRS150-Wl-l-A 208 IDH Forklift insertion side HRS150-A-20
Body Size: -, Thread: -, Port: -, Option: -, Attachment: -, Semi-Standard 1: -, Semi-Standard 2: -
Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: CG (C + G), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)