No (No Pressure Port Plug), Size of Body: 30, Check Valve: None, Residual Pressure Relief 3-Port Connection Valve: Yes, Pressure Unit: Name plate, bowl caution plate and pressure gauge units: psi, °F, T shape spacer: None, Bracket: -, Silencer: -, Coil rated voltage: -, Lead wire electrical entry: -, Protection circuit: -, Manual operation: -, CE compliant: -, Compatible Model: AC40-B, AC40B-B
Rc1/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-B, AC40B-B
Rc3/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-B, AC40B-B
: G1/4, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-B, AC40B-B
Rc3/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-B, AC40B-B
Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.7 MPa, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-B, AC40B-B
NPT3/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-B, AC40B-B
Rc1/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-06-B, AC40B
Rc3/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-06-B, AC40B
G1/4, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-06-B, AC40B
Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: No (No Pressure Port Plug), Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.7 MPa, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-06-B, AC40B
NPT1/4, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-06-B, AC40B
NPT3/8, Case Material: [Resin] Polycarbonate Case, Case Guard: No, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure Gauge: -, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: -, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer: None, Compatible Model: AC40-06-B, AC40B
wire electrical entry) P EB EA 31 50 67 81 37 37 43 6-Rc 3/4 61 103 (P , EA, EB port) 72 [ ] = A, B port Rc 3/4 Formula for manifold weight M = 0.911n + 1.621 (kg) n: Station 144 (72) 60 11 60 Non plug-in type: VV5FR5-10Station 1Bore size U side 2.3 (Electrical entry) Manual override (Non-locking) 21 R5.5 B B B B A A A A B B B n A A A B B B B A A A A 3 L2 L1 P = 51 11 11 71.5 (Pitch) P =
VZ 9 PA A B VF B A VFR PA A B VP4 L1 L2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B A A PA VZS A B SMC VFS PA A VS4 B VQ7 PA A L side R side (2n-1/8) EVS 38 D side VFN 3 68.5 (A, B port) 4n-1/4, 3/8 16 120.5 (Single) 44 155 (3 position) 145 (Double) 55 77.5
P = 43 PA 23 A A B B 14 12 A PA PA L1 L2 L2 L1 B B B 14 12 A A A A B 14 A A PA B B (2n 1/8) 4n-1/4, 3/8 2, 4 port PA L-side R-side L-side R-side D-side D-side 89 3 89 16 141 (Single) 141 (Single) 55 44 186 (Double) 186 (Double) 196 (3 position) 196 (3 position) 77.5 Bottom ported M12 connector L: Dimensions n: Stations 141.5 L n 1 Formula 2 3 4 5 6 7 8 9 10 121 5 1 12 14 PA PB 107 L1 = 43n
Air filter (5m or less) When using a solenoid valve, use a metal seal type (series VQ, VQZ, SQ, etc.).
C C RHC D D Note) Be sure to use a flat washer for the type A mounting.
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.