However, always use the positive COM with the "Z" type, since valves will not be actuated when the negative COM is used. 1.2-94 Base Mounted Type SY9000 Type43P SY9000: SS5Y9-43PStations D -02, 03, C8, C10, C12-(D)-Q Scale: 25% For external pilot specification 11 18.3 3/5 R 3/5 R A 4 A 4 A 4 A 4 A 4 A 4 (Indicator light/Surge voltage suppressor) 63.3 79.8 1 P 1 P B 2 B 2 B 2 B 2 B 2 B 2 SV

SY A B + B VFR4100 A side COM SV VFR4200 A side COM B side SYJ VFR4 00 3 4 5 A side COM B side SZ Applicable terminal: 1.25-3.5M, 1.25Y-3L, 1.25-3M Although A, B+ and B marks are indicated on the terminal block, VFR4000 can be used as either +COM or COM.

N.C. valve N.C. valve 3(EB) SOL.b SOL.a 1 2 SV A00 5(EA) B side passage symbol: Green B side manual override: Green 1(P) 4(A) 2(B) A side spool valve B side spool valve A side coil N.O. valve N.O. valve 1 2 SV B00 SOL.b SOL.a 3(EB) 5(EA) 1(P) 4(A) 2(B) N.C. valve N.O. valve 1 2 SV C00 SOL.b SOL.a 3(EB) 5(EA) 1(P) 2(B) port 3(EB) port External pilot specifications is not available for 4 position

SV 44 185 24.5 24.5 181 175 EB EA B RATE 165 MODEL SV (SI No.EX124U-SMJ1) LERR.

B B B B 32 15.3 7.5 17 16 A A A A A SV 1 (Station n) (Station 1) L1 L2 4.5 (Pitch) P = 10.5 SZ (Light/Surge voltage suppressor) 15.5 15.5 (Station n) (Station 1) SY + + (Light/Surge voltage suppressor) A A 20 48.5 [55.5] 15 5 SYJ B B + + 1.5 One-touch fitting (A, B port) Applicable tubing O.D.: 4, 5/32" (Pitch) P = 10.5 16 33.1 A A 20 SX 15 Courtesy of Steven Engineering, Inc.-230 Ryan Way

Sysmac G5 R88M-K OMRON Corporation MINAS-A4 MSMD Panasonic Corporation MINAS-A5 MSMD/MHMD is FANUC CORPORATION S-FLAG MA/MH/MM NIDEC SANKYO CORPORATION SV SV-M/SV-B KEYENCE CORPORATION ALPHA5 GYS/GYB FUJI ELECTRIC CO., LTD. FALDICGYS AR AR ORIENTAL MOTOR Co., Ltd. AZ AZ Ezi-SERVO EzM FASTECH Co., Ltd. MP-/VPMP/VP Rockwell Automation, Inc.

length) (A, B port) 2-One-touch fittings (A, B port) Applicable tubing O.D.: 4 6 8 SV SZ (Mounting hole)s SY Manual override (Press and turn for the locking type.)

(L5) DIN rail holding screw (For DIN rail mounting) L1 EX260 SY SV VQC S0700 4(A) port side: Blue (For rubber seal) : Gray (For metal seal) 2(B) port side:Yellow Silencer (exhaust port) (Built-in silencer specification) Light/surge voltage suppressor 8 DIN rail 5.5 35 5.5 B A B A B A A 14 A B A 14 A B 14 A 14 A 14 A (114.8) 113.4 97.5 101 1.4 81.2 61.7 B 12 B 12 B 12 B 12 B 12 10.9 4.7 (5.9

length) (A, B port) 2-One-touch fittings (A, B port) Applicable tubing O.D.: 4 6 8 SV SZ (Mounting hole)s SY Manual override (Press and turn for the locking type.)

A: Orange B: Green G: 300 H: 600 (Lead wire length) SV (Mounting hole) SZ SY SYJ SX (Pitch) (P , EA, EB port) M5 (n) (2) (1) stations (Pitch) (Pitch) 2-One-touch fittings (A, B port) Applicable tubing O.D.: 4 6 (A, B port) L plug connector (L) M plug connector (M) (Lead wire length) 300 300 (Lead wire length) 104.5 (3 position) 92 (3 position) (mm) 3 49 41 4 59.5 51.5 5 70 62 6 80.5 72.5

(L5) DIN rail holding screw (For DIN rail mounting) L1 EX260 SY SV VQC S0700 4(A) port side: Blue (For rubber seal) : Gray (For metal seal) 2(B) port side:Yellow Silencer (exhaust port) (Built-in silencer specification) Light/surge voltage suppressor 8 DIN rail 5.5 35 5.5 B A B A B A A 14 A B A 14 A B 14 A 14 A 14 A (114.8) 113.4 97.5 101 1.4 81.2 61.7 B 12 B 12 B 12 B 12 B 12 10.9 4.7 (5.9

(L5) DIN rail holding screw (For DIN rail mounting) L1 EX260 SY SV VQC S0700 4(A) port side: Blue (For rubber seal) : Gray (For metal seal) 2(B) port side:Yellow Silencer (exhaust port) (Built-in silencer specification) Light/surge voltage suppressor 8 DIN rail 5.5 35 5.5 B A B A B A A 14 A B A 14 A B 14 A 14 A 14 A (114.8) 113.4 97.5 101 1.4 81.2 61.7 B 12 B 12 B 12 B 12 B 12 10.9 4.7 (5.9

How to see the serial number Z O 001 January 2021 Z O 001 Year Symbol Remarks Month Symbol Remarks Serial no. 2021 Z Repeated from A to Z in alphabetical order 1 O Repeated from O to Z in 2022 A 2 P alphabetical order, with O for January and Z for December 2023 B 3 Q Fig. 1-1 Position of the product label HRS090 Series 1.4Product Label 1-3 HRX-OMT002 Chapter 1 Safety Instructions 1.5 Safety

port side: Green Series EX600 Series SY Series SV Series S0700 Series VQC Light/surge voltage suppressor 4 x 5.3 (For mounting) End plate Marker groove L4 16.5 L5 L3 47 8 90 8 106 128.8 83.8 5 47.2 14.3 29.6 8 5.5 54.2 B A B A 35 A A A A A B B B B B Input connector SI Unit Output connector Power connector Connector for Handheld Terminal Valve plate FE terminal (5.1) (5.3) Digital Output

PV PV PV SV SV SV Alarm display menu SEL SEL SEL Pressure of lower pressure refrigerant circuit READY time Unused Alarm The latest PV PV PV PV SV SV SV SV SEL SEL SEL SEL Unused Offset mode Unused Alarm PV PV PV PV SV SV SV SV SEL SEL SEL SEL Accumulated operation time of the pump Unused Offset temperature PV PV PV Alarm The oldest SV SV SV SEL SEL SEL PV Accumulated operation time of the

CE-certified Symbol EX124D-SDN1-X188 DeviceNet (Negative common) Q A, B port size (Inch) A, B port size (Metric) P, E port Applicable series P, E port Applicable series A, B port Symbol C4 C6 C8 M A, B port Symbol N3 N7 N9 M One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 A, B ports mixed One-touch fitting for 5/32" One-touch fitting for 1/4" One-touch fitting for

Refer to external dimensions in pages 1-6-51 to 1-6-53, and then mount it. 1-6-50 Body Ported Series SX3000/5000/7000 SX7000: SS5X7-20PStations L1 L2 10 (A, B port) 2n2-One-touch fitting (Pitch) Applicable tubing O.D.: 8 (A, B port) 2n1-Rc 1/4 (Mounting hole) 4-4.5 P = 20.5 13.5 10 16.5 9.4 21 19.5 76.8 22.4 11.5 SV B A B A B A B A B A B A B A 19 20.5 EA EB P SZ EB EA P 20 20 21 21 SY 62.5

SV SV SV Press the 2 sec. Press the 2 sec. SV SEL SEL SEL SEL Circulating fluid return port Run timer Pressure unit PV PV PV PV SV SV SV SV SEL SEL SEL SEL Temperature of the compressor inlet.

HRZ001-L-Z HRZ001-L1-Z HRZ002-L-Z HRZ002-L1-Z HRZ004-L-Z HRZ004-L1-Z HRZ004-H-Z HRZ004-H1-Z HRZ008-H-Z HRZ008-H1-Z HRZ001-L2-Z HRZ002-L2-Z HRZ004-L2-Z HRZ008-L2-Z HRZ002-W-Z HRZ002-W1-Z HRZ008-W-Z HRZ008-W1-Z HRZ010-WS-Z HRZ010-W1S-Z HRZ010-W2S-Z HRZ001-H-Z HRZ001-H1-Z HRZ002-H-Z HRZ002-H1-Z HRZ008-L-Z HRZ008-L1-Z Applicable model Circulating fluid recoverable volume Note 1) L 15 16 17 Purge