Turn to "0" in the position control and speed control. 1r/min 21 Speed limit value (by 0.1 r/min) The speed limit value at the torque control or stopper control is displayed.
motor speed and displayed. 1r/min 6 Droop pulse (by 100 pulse) The droop pulse on the deviation counter is displayed in units of 100 pulse.
motor speed and displayed. 1r/min 6 Droop pulse (by 100 pulse) The droop pulse on the deviation counter is displayed in units of 100pulse.
Rc1/8 Rc1/8 Rc1/8 Rc1/4 TN NPT1/8 NPT1/8 NPT1/8 NPT1/4 TF G1/8 G1/8 G1/8 G1/4 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 d b C H B H 4 8 8 10 d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 B 14 26 32 41 C 16.2 30 37 47.3 Part number SNJ-016B SN-020B SN-032B SN-040B Applicable bore size (mm) 15 20 25, 32 40 161 Specific Product Precautions Be sure to read before handling. 12-CY1B/3B/1R
Size: 3/8, Thread: M Thread, Rc(PT), Port Size: 3/8, Accessory: -, Option 1: -, Option 2: -
error AL20 Memory error AL21 DC line fuse cut AL22 Circulating fluid discharge temp. sensor failure AL23 Circulating fluid return temp. sensor failure AL24 Compressor intake temp. sensor failure AL25 Circulating fluid discharge pressure sensor failure AL26 Compressor discharge pressure sensor failure AL27 Compressor intake pressure sensor failure AL28 Pump maintenance AL29 Fan maintenance AL30
error AL20 Memory error AL21 DC line fuse cut AL22 Circulating fluid discharge temp. sensor failure AL23 Circulating fluid return temp. sensor failure AL24 Compressor intake temp. sensor failure AL25 Circulating fluid discharge pressure sensor failure AL26 Compressor discharge pressure sensor failure AL27 Compressor intake pressure sensor failure AL28 Pump maintenance AL29 Fan maintenance AL30
pump operation Stop AL15 Stop Refrigerant circuit pressure (high pressure side) drop AL20 Stop Memory error AL22 Stop Circulating fluid discharge temp. sensor failure AL24 Stop Compressor intake temp. sensor failure AL26 Stop Compressor discharge pressure sensor failure AL27 Stop Heat exchanger inlet temp. sensor failure AL28 Continue Pump maintenance AL29 Continue Fan motor maintenance AL30
Alarm message AL38 Compressor discharge temp. rise AL39 Internal unit fan stoppage AL40 Dustproof filter maintenance Note 1) AL41 Power stoppage AL42 Compressor waiting AL43 Fan breaker trip Note 1) AL44 Fan inverter error Note 1) AL45 Compressor breaker trip Note 2) AL46 Compressor inverter error AL47 Pump breaker trip Note 2) AL48 Pump inverter error AL49 Air exhaust fan stoppage Note 3) AL30
Alarm message AL38 Compressor discharge temp. rise AL39 Internal unit fan stoppage AL40 Dustproof filter maintenance Note 1) AL41 Power stoppage AL42 Compressor waiting AL43 Fan breaker trip Note 1) AL44 Fan inverter error Note 1) AL45 Compressor breaker trip Note 2) AL46 Compressor inverter error AL47 Pump breaker trip Note 2) AL48 Pump inverter error AL49 Air exhaust fan stoppage Note 3) AL30
Part Number Description: BOWL ASSEMBLY (AL30) Product Line: E Product Line Description: AIRLINE EQUIPMENT Click here to report information errorImage shown may not match exact part number
BOWL ASSEMBLY, AL30-A, AIRLINE EQUIPMENT, AF MASS PRO, 21, AF MASS PRO NO SIZE RATING, 0.22046 lb
The AL30/40/50/60 are equipped with a check valve on the body.
Therefore, lubricant can be supplied by removing the lubrication plug even when the product is pressurized.
Loosen the lubrication plug slowly, by about 1 turn, to release the pressure inside the bowl.
When pressure in the bowl is released, remove the lubrication plug and supply lubricant.
In addition, old AL series lubricators (e.g., AL3000-02) from older AC series modular F.R.L. units (4 digits: AL□□□□) can be replaced with lubricators from the AL□□-A series (AL30-02-A). (The bowl assembly cannot be replaced on its own.)
A 1000 cm2 tank type is available for standard AL30 to 60 series products.
Details on the 1000 cm2 tank type can be found here.
For AL30-A to AL60-A series lubricators, when the lubrication plug is opened under the pressure of the lubricator, air bubbles may be generated at the end of the oil passage (sometimes they are not). This is also caused by the bowl’s internal pressure being lower than the outlet pressure.
The AL modular design allows connection with other SMC air preparation equipment., DAMPER RETAINER ASSEMBLY AL30, AIRLINE EQUIPMENT, AL MASS PRO, 21, AL MASS PRO NO SIZE RATING, .00887 lb, ModelPort SizeDimensionsMounting Bracket Kit (Optional) ACDEFGHJKLMNPQRSTWAL30NPT 3/8531623/85357304140236.58532.33544M4 X 0.734.5AF30P-050AS-X480
Communication error AL20 Memory error AL21 DC line fuse cut AL22 Circulating uid discharge temp. sensor failure AL23 Circulating uid return temp. sensor failure AL24 Compressor intake temp. sensor failure AL25 Circulating uid discharge pressure sensor failure AL26 Compressor discharge pressure sensor failure AL27 Compressor intake pressure sensor failure AL28 Pump maintenance AL29 Fan maintenance AL30
Case: [Resin] Polycarbonate Case, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL20-A, AL30-A, AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Sight dome assembly
Case: -, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL30-A, Type: Damper holding assembly