SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2E10-45Z-A-XB9"

Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,

Inner Diameter(φ): 10, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire Length(m): N/A,

Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,

CYL,DOUBLEACTING, ACTUATOR, CJ2 ROUND BODY CYLINDER, EE, 10MM CJ2 DBL-ACT AUTO-SW, 0.44092 lb

MM R1 MM CJP ND E1 NX1 A U1 R2 H Z E1 NX U1 LB A A NX A1 CJ2 A1 U1 LB JCM Part no.

Double clevis type Lock location Port (A) (A) (A) (A) (A) (A) (A) (B) (D) (B) (D) (B) (B) (D) (D) (B) (B) (B) (D) (D) (D) CLS (C) (C) (C) (C) (C) (C) (C) Cushion valve 1.

A Series MGC 20 to 50 SZ + Stroke B D port C port A, B port B port A C port A port D port A View A-A GD GD Front mounting flange SB + Stroke B SA + Stroke A ZZ + Stroke A + Stroke B Bracket mounting With R Without R Stroke A stroke Stroke A + Stroke B ( ) Bore size (mm) W1 W2 SB SA GD ZZ GC SZ availability 30 30 Up to 200 96 50 9 176 21 20 35 st or more 89 110 30 30 96 50 9 183 21 25 60 st

Do not use a load that generates surge voltage. If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box.

Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.

Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S

Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.

to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).

CS1 C76 3 Low Speed XB9 4 Heavy-duty Scraper XC4 C85 Mounting Bore size Stroke XB9 C85 Mounting Bore size Stroke XC4 C85 N, E, F, Y 20, 25 mm N, E, F, Y 20, 25 mm C95 The cylinder does not generate any stick-slip phenomenon even at the rated low speed of 10 to 50 mm/s. All strokes drive at a constant speed smoothly. A heavy-duty scraper is used as wiper ring.

B PB + Stroke A 4-EE (NPTF) 4-DD D across flats Stroke A Stroke B 4-NT Depth ND SN + Stroke A + Stroke B LF + Stroke A + Stroke B ZB + Stroke A + Stroke B Bore size (in) MM KK A AA B BA C D DD E EA EE G J R TN WF XT Y LF P A PB PC 150 (1.5") 5/8 7/16-20 3/4 2.02 1 1/8 1 1/8 3/8 9/16 1/4-28 2 0.3 3/8 1.26 1.1 1.43 5/8 1 1 15/16 1.71 7.26 2.36 2.40 1.24 200 (2") 5/8 7/16-20 3/4 2.6 1 1/8 1

Auto switch capable How to Order NC D A1 B 150 0400 + 0200 H XC11 R Mounting Bore size Auto switch Stroke B-A Dual operationSingle rod Stroke A Cushion Both ends N W/o cushions H Head end R Rod end Dimensions PA + Stroke B PB + Stroke A 4-EE (NPTF) 4-DD D across flats Stroke A Stroke B 4-NT Depth ND SN + Stroke A + Stroke B LF + Stroke A + Stroke B ZB + Stroke A + Stroke B Bore size (in)

Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,

Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: None, Lead Wire Length(m): N/A,