SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2F16-30AZ-A93-B"

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: None, Lead Wire

Magnet: D (Built-in Magnet), Series: J2W, Mounting: B (Basic Style), Bore Size: 16mm, Stroke: 30mm, Cushion: A (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)

Magnet: D (Built-in Magnet), Series: J2W, Mounting: B (Basic Style), Bore Size: 10mm, Stroke: 30mm, Cushion: A (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Air cushion, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Air cushion, Auto Switches: None, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Air cushion, Auto Switches: None, Lead Wire

Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm

Inrush Current Flow Time (Reference) 200 V Current 100 V 0 5 15 10 20 25 30 Time [Second] 2 Mounting position of the heater Heater symbol XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 H4 (100C) (a) (a) (b), (c) (a), (b), (c) H5 (120C) (a) (b), (c) (b), (c) (a), (b), (c) (b), (c) (b) (a) (c) Heater (Option) 17 Aluminum High Vacuum Angle Valve: With Heat-resistant Auto Switch XLm Series Made to

MY1CW16/20 MY1MW16/20 MX B A MTS Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) MY 16 20 Mounting position 16 20 Mounting position Mounting position 16 20 93 94 A A A 73 74 70 90 CY 107 106 B B B 87 86 90 110 6.5 7 8.5 6.5 Operating range Note) Operating range Note) Operating range Note) 11 7.5 MG Courtesy of Steven

A B Hs Hs Hs Hs Hs Hs Hs Hs Hs Hs D-M9lV D-M9lWV D-M9lAV D-A9lV D-M9lV D-M9lWV D-M9lAV D-A9lV 17 B A A B D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 D-F7l D-F7lW D-J79 D-J79W D-F7BA D-F79F D-A7lH D-A80H 17 A B A B D-F7lV D-F7lWV D-F7BAV D-A7l D-A80 D-A79W D-H7C 17 A B A B D-C73C D-C80C D-J79C D-A73C D-A80C 17 Auto Switch Made to Order B A B A 102 C85/C75 Series Auto Switch Proper Mounting

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5

1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 1/8, 1/4 500 1.5 0 1,000 2,000 3,000

CM3 Auto Switch Proper Mounting Position (Centralized piping type, With end lock) CG1 (mm) Auto switch model D-H7l D-H7C D-H7lW D-H7BA D-H7NF CG3 D-C7l D-C80 D-C73C D-C80C D-G39A D-K39A D-A3lA D-A44A D-M9l(V) D-M9lW(V) D-M9lA(V) D-A9l(V) D-G5NT D-B5l D-B64 D-B59W JMB MB A B A B A B A B A B A B A B A B Bore size MB1 20 10.5 (8) 9.5 (7) 6.5 (4) 5.5 (3) 0.5 () 0 () 6 (4) 5 (3) 2.5 (0.5) 1.5

D-K39 D-K39C D-A5m D-A6m D-A3m D-A3mC D-A44 D-A44C Auto switch model D-G5m D-K59 D-G5NT D-G5mW D-K59W D-G5BA D-G59F D-F5m D-J59 D-F59F D-F5mW D-J59W D-F5BA D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-B5m D-B64 D-A9m D-A9mV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 9 9 5 5 2.5 2.5 4.5 4.5 2 2 5.5 5.5 3 3 10.5 10.5 0 0 1 1 0 0 50 9.5 8.5 5.5 4.5