SMC Corporation of America
Elite Part Number Search
Search Results "CDLSB180TN-1200-D"

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 1000mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 350mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 500mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 900mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 150mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Magnet: Built-in, Mounting: Standard, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: NPT, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Lock Unit

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

,B6 D-C7,C8 D-C73C D-C80C D-G5 D-K5 D-G5NTL D-H7W D-H7F D-H7BAL D-B59W D-H7 D-H7C D-C73C D-C80C D-G5W, K59W D-G59F D-G5BAL Bore B 16 (24) 16 (24) 17 (25) 19.5 (28.5) 24 (36) 24 (36) 32.5 (46.5) 32.5 (46.5) B 20.5 (28. 5) 20.5 (28.5) 21.5 (29.5) 24 (33) 28.5 (40.5) 28.5 (40.5) B 17.5 (25.5) 17.5 (25.5) 18.5 (26.5) 21 (30) 25.5 (37.5) 25.5 (37.5) 34 (48) 34 (48) B 18 (26) 18 (26) 19 (27) 21.5

24VDC 5~20MA YES D-F59 28VDC OR LESS 150MA 3 WIRE (NPN) 600 (6 Bore) 24VDC 5~20MA D-F5P 100MA 3 WIRE (PNP) BT-18A 800 (8 Bore) D-A54 100VAC 5~25MA YES D-J59 24VDC 5~150MA 2 WIRE BT-20 1000 (10 Bore) 200VAC 5~12.5MA (10~28VDC) 1200 (12 Bore) D-A56 4~8VDC 20MA YES D-F59W 28VDC 80MA 3 WIRE (NPN) D-A59W 24VDC 5~40MA YES D-F59PW 80MA 3 WIRE (PNP) 24VAC/DC 50MA D-J59W 24VDC 5~40MA 2 WIRE D-A64

24VDC 5~20MA YES D-F59 28VDC OR LESS 150MA 3 WIRE (NPN) 600 (6 Bore) 24VDC 5~20MA D-F5P 100MA 3 WIRE (PNP) BT-18A 800 (8 Bore) D-A54 100VAC 5~25MA YES D-J59 24VDC 5~150MA 2 WIRE BT-20 1000 (10 Bore) 200VAC 5~12.5MA (10~28VDC) 1200 (12 Bore) D-A56 4~8VDC 20MA YES D-F59W 28VDC 80MA 3 WIRE (NPN) D-A59W 24VDC 5~40MA YES D-F59PW 80MA 3 WIRE (PNP) 24VAC/DC 50MA D-J59W 24VDC 5~40MA 2 WIRE D-A64

D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV ( ) MY1CW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 63 50 40 32 25 Mounting position 40 32 25 Mounting position 25 Mounting position 32 40 50 63 A 323.5 278.5 157.5 127.5 97.5 157.5 127.5 97.5 97.5 127.5 157.5 278.5 323.5 A A B 136.5 121.5