Magnet: Built-in Magnet, Mounting: Head Trunnion, Type: Air Cushion, Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 250mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewire Connection: -, Number: -, X Option: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead

Bearing Type: M (Slide bearing), Bore Size: 25mm, Port Type: TN (NPT), Stroke: 250mm, Auto Switch: A90--Reed, AC Volt, Horizontal

Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Type: A (Air Cushion), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 250mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A90--Reed, AC Volt, Horizontal

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead

Bearing Type: Slide bearing, Bore Size: 25mm, Port Type: NPT, Stroke: 250mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc,

Clean Series: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting: L (Axial Foot Style), Bore Size: 32mm, Port Thread: Rc, Stroke: 250mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Auto Switch: C80C--Reed, DC Volt >5 <24, AC Volt <100, Connector, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Type: Pneumatic, Mounting: L (Axial Foot), Bore: 32mm, Port Thread: Rc, Stroke: 250mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: V (Single Knuckle Joint), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical

Clean Series: Vacuum Suction Type, Magnet: Built-in, Mounting: Axial Foot Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 250mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Auto Switch: C80C--Reed, DC Volt >5 <24, AC Volt <100, Connector, Lead Wire or Prewired Connector: 3m, Number: -

A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

Special function Electrical entry Wiring (Output) Lead wire length (m) Auto switch model Load voltage DC Perpendicular In-line AC Applicable load Pre-wired connector Indicator light Type 3(L) SDPC Reed switch Solid state switch Diagnostic indication (2-color indication) M9BWV M9BW Yes 24 V 12 V Relay, PLC Grommet 2-wire A90 No IC circuit 100 V or less *Additional symbols for auto switch

Auto Switch Specifications Grommet Electrical entry : In-line PLC: Abbreviation for Programmable Logic Controller D-A90/D-A90V (without indicator light) D-A90/D-A90V Auto switch part no.

A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indicator) Grommet Yes A79W V V 1 Water resistant type auto switches can be mounted on the above models, but SMC cannot guarantee water resistance.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

CXSJ10 D B (mm) D-A90, D-A96 25.7 29.7 3.2 D-A93 25.7 27.2 5.7 D-F9 29.7 2.8 19.7 7.2 Symbol A B Note) C D A C Note) For D-A90, D-A96, and D-A93, only outward electrical entry (D dimension) is available.