/Y7PV D-Y7W/Y7WV D-Y7BA D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA 5 5 5 5.5 5.5 5 5 5 5.5 5.5 Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63.
400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max.
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: P5DW--Solid State, 2-color Indication, Magnetic Resist., 2 Wire, Lead Wire or Prewired Connector: 0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out, Number: 4 pcs., Made to Order: -
Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5
Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)
(mm) D-M9V D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A90V D-A96V D-A93V Bore size (mm) D-A90 D-A96 D-A93 D-M9 D-M9W Bore size (mm) Mounting pattern q, w Mounting pattern e 32 32 20 22 35 20 10 15 25 12 5 10 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries.