SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2G50-400-D"

Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-M9E, D-M9EV (With indicator light) Auto switch model D-M9NE D-M9NEV D-M9PE D-M9PEV D-M9BE D-M9BEV Output signal turns on when no magnetic force is detected.

Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch

150 200 250 300 350 400 450 500 10kg 8kg 18kg 16kg 14kg Speed (mm/s) Speed (mm/s) Model Mounting orientation LJ1H30 12kg Load movement direction 10kg 600 14kg 400 L1 (mm) L3 (mm) 12kg 20kg 50 100 a = 1000 16kg 18kg 20kg Pitching Yawing Vertical Vertical m a a = 3000 a = 2000 200 100 200 300 400 500 600 0 100 200 300 400 500 600 0 L1 Mep Stroke (mm) Stroke (mm) 0 5 10 20 15 Transfer load

D Bypass port dia. D Bypass port dia.

Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y59A, D-Y69A D-Y59A D-Y69A D-Y7P D-Y7PV D-Y59B D-Y69B Auto switch model no.

Bore Model No. 150 (1.5) 200 (2) 250 (2.5) 325 (3/25) 400 (4) D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 M8-3pin M8-4pin M12-4pin Connector Style 1 2 1 4 Pin arrangement 2 1 3 4 4 3 3 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300m/s2 Applicable standards Impact resistant IP degress of protection Insulation resistance Withstand voltage IP-67 (IEC529 standard) 100Mor

/C8 D-H7 A B 12 Hs 14.5 24.5 Auto switch D-B5/B6 D-G5/K5 A B 8.5 Hs 14.5 11 Auto switch D-B7/B8 D-G7/K7 Proper Auto Switch Mounting Position Auto Switch Mounting Height D-G5/K5 D-G5W D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F D-G5 D-K59 D-G5W D-K59W D-G5NTL D-G5BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-C7/C8 D-H7 D-H7W D-H7NF D-H7BAL D-B7/B8 D-B73C

D C B A Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

For details about auto switches, refer to the Web Catalog. stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 * Please consult with SMC for non-standard strokes as they are produced as special orders. 544 Electric Actuator/Rod Type 25A-LEY Series AC Servo Motor 25, 32 Size Secondary

, D-M9V, D-F9W, D-F9WV Note) The operating range is a guide including hysteresis, but is not guaranteed.

LEF D-M9NAV D-M9NA D-M9BA D-M9BAV D-M9PAV D-M9PA Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction LEJ 3-wire 2-wire Wiring type NPN PNP Output type LEL 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage LEM 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage

400 450 500 10kg 8kg 18kg 16kg 14kg Allowable dynamic moment Speed (mm/s) Speed (mm/s) Model Mounting orientation LJ1H30 12kg Load movement direction 10kg 600 14kg 400 L1 (mm) L3 (mm) 12kg 20kg 50 100 a = 1000 16kg 18kg 20kg Pitching Yawing m a Vertical Vertical a = 3000 a = 2000 200 100 200 300 400 500 600 0 100 200 300 400 500 600 0 L1 Mep Stroke (mm) Stroke (mm) 0 5 10 20 15 Transfer

(mm) Auto Switch Mounting Height D-A9l(V) D-M9l(V) D-M9lW(V) D-M9lA(V) D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 Auto switch model D-B5l D-B64 D-B59W D-G5NT D-H7C D-G39A D-K39A D-A3lA D-A44A D-C73C D-C80C Hs Hs Hs Hs Hs 20 24.5 25.5 25 60 69.5 25 27 28 27.5 62.5 72 32 30.5 31.5 31 66 75.5 40 34.5 35.5 35 70 79.5 Bore size D-X Technical Data 263 CM2 Series Auto Switch Proper Mounting Position

There may be large variations depending on the surrounding environment (variations on the order of 30%). 66 Solid State Switches/Direct Mount/ D-Y59 /D-Y69 /D-Y7P(V) Series MGP Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.

BMY3-016 Auto switch model Tightening torque D-M9l(V) D-M9lW(V) 0.10 to 0.15 210 Solid State Auto Switch Direct Mounting Type D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.

B A C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

Auto Switch Proper Mounting Height (Standard type) [mm] Auto switch model D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-F5NT D-Y59l D-Y7P D-Y7lW D-Y7BA D-Z7l D-Z80 D-M9l D-M9lW D-M9lA D-A9l D-A9lV D-M9lV D-M9lWV D-M9lAV D-A5l D-A6l D-A59W D-Y69l D-Y7PV D-Y7lWV D-P3DWA D-P4DW D-G39 D-K39 D-A3l D-A44 Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23

CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Auto Switch Mounting Height (mm) MB D-Z7/Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F59F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A5 D-A6 D-A59W D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV Bore size D-Y7BAL D-A44 D-P5DWL MB1 (mm) Ht Hs

Mounting bolt C D Mounting Bolt Size for NCQ8B056 to 250(Without Auto Switch) (Inch) Model C D Bolt size Model C D Bolt size NCQ8B056-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B075-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B106-012 025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCQ8B150-012 025 037 050 062 075 087 100 125 150

CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin arrangement CS1 3 4 4 3 3 C76 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300 m/s2 Applicable standards Impact resistant IP degress of protection Insulation resistance Withstand