B A C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.
SY3 40 B Electrical entry D Manual override C B A C D Indicator light/ Surge voltage suppressor Type of actuation A Rated voltage 1 2 position single solenoid 2 2 position double solenoid 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center Indicate in the station table below.
across flats KK NCM 1/32 R NCA 0.001 0 EA MM BA TD UV E AA B D-X A C FA G TT J LF + Stroke ZB + Stroke R WF TL TM TL E 20Data TD0.001 0 ZB TL TM TT UM UV WF A Y AA LF B P BA XI C D DD E EA EE FA G MM J R KK Bore size (in) 200 (2") 1 5 1/8 1 3 1.18 5 2.56 1 3/8 1 1/8 2.09 2.6 3 5/8 1 1/2 2.40 1 1/8 3.29 1/2 7/8 5/16-24 2 1/2 0.3 3/8 3/8 1 1.26 1.06 1.84 3/4-16 250 (2.5") 1 5 1/4 1 3 1/2 1
CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin arrangement CS1 3 4 4 3 3 C76 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300 m/s2 Applicable standards Impact resistant IP degress of protection Insulation resistance Withstand
B A C D A B C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 46 26 46 26 30 42 42 30 10 48 28 48 28 32 44 44 32 Electrical entry (Fetching direction) Type Model Features D-A90 D-Z80 D-Y69A D-Y69B D-Y7PV D-Y7NWV D-Y7PWV D-Y7BWV 50, 63 Grommet (In-line) Without
C 0.2 C 0.2 B 0.2 B 0.2 A 0.2 A 0.2 D Bore size (mm) A (mm) B (mm) C (mm) Bore size (mm) A (mm) B (mm) C (mm) D (mm) (mm) Hexagon socket head cap screw Hexagon socket head cap screw MGPM MGPL 12 50 50 18 41 10 8 M4 x 0.7 140 50 116 32 M12 x 1.75 16 80 56 22 46 12 10 M5 x 0.8 214 66 170 47 M16 x 2 Connection thread size Proper tightening torque (Nm) a dimension 20 72 24 54 14 12 M5 x 0.8 25
D-sub connector conforming to MIL-C-24308 (Refer to page 39.) Dedicated connector (Refer to page 39.) D-sub connector conforming to MIL-C-24308 (Refer to page 39.)
(B) (D) (B) (D) (B) (D) (B) (D) (B) (D) (B) (D) (B) CA2 Double acting, Single rod Air cylinder CP95 CA2W Double acting, Double rod (C) (C) (C) (C) (C) (C) (C) CA2 6 Cushion valve CA2Q Double acting, Single rod Low friction type NCM CBA1 Double acting, Single rod Cylinder with end lock 1.
D-sub connector type) Manifold (c) DIN rail release button U side Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Position for increasing stations (a) Bolt (b) Block separation (c) DIN rail release button lever Lid D side Replacement Parts Description SX3000 Part
Positioning Time Guide Positioning time A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)
U side D side D D D D D D 3 2 1 Stations How to Order Solenoid Valve 10 SV 1 1 0 0 F 5 Note) Clean series Note) Available with manifold block for station additions. Refer to the WEB catalog.
Listed and CSA Certified for Hazardous LocationsClass I, Div 1, Group C and D Class II, Div 1, Groups E, F, and G; Div 2 Groups A,B,C,D,E,F, AND G. Mtg.
(kg) Applicable dryer Port size NPT A B C D E D E Part no.
Contact SMC regarding the specifications for psi unit and F. 229 Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG20K/30K/40K Construction AWG20K AWG30K/40K B D P A A K U C C C S O P H L to K U C S O H L to B D D-D C-C A-A B-B !0 o !1 !0 o !1 y y !2 !
d Dd9 D C L l m H B Note 1) d (Through hole diameter) Bore size (mm) Clevis Knuckle Part no.
R C US US C R R R R R R R US C US C US C US C US C US C SERIAL NO.
D-X Auto switch 20Data Proper Auto Switch Mounting Position Auto Switch Mounting Height D-A5/A6 D-A3/ A3C D-A44/ A44C D-G39/ G39C D-K39/ K39C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F D-F5 D-J5 D-F59F D-F5W D-J59W D-F5BAL D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F Auto switch model D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W
(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Hs Hs Ht Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S
(Not mountable after the time of shipment) RHC MK(2) Auto Switch Mounting Height RS Q G D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G59F D-F5 D-J5 D-F5W D-J59W D-F59F D-F5NTL Auto switch model D-Z7/Z80 D-Y59 D-Y7P D-Y7W D-Y69 D-Y7PV D-Y7lWV D-A44 D-A44C D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W RS H A RZQ Bore size (mm) Hs Ht Hs Ht Hs Hs Hs Hs Ht Hs Ht Hs Hw Hs Hw MI W S
Series MGP Series MGPS (d = Thread O.D.) (d = Thread O.D.) 1.5d or more 2d or more D By-pass port dia. D By-pass port dia. C 0.2 C 0.2 B 0.2 B 0.2 Piping Caution A 0.2 A 0.2 Depending on the operating conditions, piping port positions can be changed by using a plug.